scholarly journals Effect of Activation Mode on Flexural Strength and Elasticity Modulus of Dual Cure Resin Cements

2016 ◽  
Vol 18 (1) ◽  
pp. 61
Author(s):  
Isadora Guimaraes DDS, MSc, PhD ◽  
Fabian Murillo DDS, MSc ◽  
Mario De Goes DDS, MSc, PhD

Objective: This study evaluated the effect of the activation mode on flexural strength and elasticity modulus of four dual cure resin-based cements.  Methods: Two self-adhesive resin cements (Clearfil SA Cement (CSA) and  RelyX U100 (U)) and two conventional resin cements (Clearfil Esthetic Cement (CE)and RelyX ARC (ARC)) were used to produce a total of 45 bar specimens (7x2x2 mm) using three different activation modes (n=15): Direct light-cure (D), Indirect light-cure using a 2mm composite resin barrier (I) and Self-cure (S). Three-point flexural tests were performed after 24 hours water storage at 37° C, using a universal testing machine (Instron) at a cross-speed of 0.5 mm/min until fracture. Flexural strength (MPa) and elasticity modulus values were subjected to ANOVA and Tukey’s Test (=0.05). Results: Data revealed that light polymerized groups presented statistically higher flexural strength (CSA/D=113.63 ± 19.65; CSA/I=80.66 ± 23.74; U/D=101.33 ± 9.8; U/I=94.96 ± 36.9; CE/D=219.08 ± 39.94; CE/I=226.42 ± 34.59; ARC/D=150.03 ± 26.15; ARC/I=111.78 ± 14.28) and also  elasticity modulus values (CSA/D = 2.9 ± 0.6; CSA/I = 1.5 ± 0.4; U/D = 2.9 ± 0.5; U/I = 2.6 ± 1.4; CE/D = 6.5 ± 1.3; CE/I = 5.8 ± 1.0; ARC/D = 4.2 ± 0.93; ARC/I = 2.5 ± 0.5) compared to self-cured groups (flexural strength: CSA/S=65.81 ± 21.84; U/S=53.62 ± 28.73; CE/S=129.02 ± 51.67; ARC/S=77.98 ±19.61 and elasticity modulus: CSA/S = 1.4 ± 0.5; U/S = 1.2 ± 0.7; CE/S = 2.2 ± 1.5; ARC/S = 1.0 ± 0.5). The usage of a composite resin barrier only affected the mechanical properties of ARC and CSA. Conventional resin cements presented higher flexural strength values than the self-adhesive cements. CE presented the highest values compared to all other cements. No statistical difference was observed between self-adhesive cements. Conclusion: Light-curing of resin luting cements produced higher flexural strength for all tested materials. Similar mechanical behavior was observed for the tested self-adhesive cements. 

2017 ◽  
Vol 15 (4) ◽  
pp. 258
Author(s):  
Marcelo Giannini ◽  
Andreia Assis Carvalho ◽  
Ariovaldo Stefani ◽  
Wladimir Franco de Sá Barbosa ◽  
Lawrence Gonzaga Lopes

Self-adhesive, dual-polymerizing resin cements require no treatment to the prepared tooth surfaces before cementation. Aim: The aim of this study was to evaluate the influence of curing mode on bond strength (BS) of three cementing systems to bovine dentin. Methods: The buccal enamel surfaces of 50 bovine incisors were removed to expose dentin and to flat the surface. The teeth were divided into five groups (n=10), which consisted of two resin cements (Multilink and Clearfil SA Cement) that were tested in dual- (halogen light for 40 s) and self-cured modes, and a control (RelyX ARC). Two cylinders of resin cements (1.0 mm X 0.75 mm) were prepared on each bonded dentin surface. After 24h at 37oC, resin cylinders were subjected to micro-shear testing in a universal testing machine (4411/Instron - 0.5 mm/min). Data were statistically analyzed by two-way ANOVA, Tukey and Dunnett`s test (5%). Results: Multilink showed higher BS than those observed on Clearfil SA. Light-curing resulted in higher BS for both Multilink and Clearfil SA. When Multilink was light-cured, no significant difference on BS was demonstrated between it and RelyX ARC. Conclusions: The highest BS values were obtained in control group and light-cured Multilink resin cement.


2007 ◽  
Vol 18 (3) ◽  
pp. 235-239 ◽  
Author(s):  
Rubens Nisie Tango ◽  
Mário Alexandre Coelho Sinhoreti ◽  
Américo Bortolazzo Correr ◽  
Lourenço Correr-Sobrinho ◽  
Rafael Leonardo Xediek Consani

This study evaluated the Knoop hardness of Enforce resin cement activated by the either chemical/physical or physical mode, and light cured directly and through ceramic (HeraCeram) or composite resin (Artglass). Light curing were performed with either conventional halogen light (QTH; XL2500) for 40 s or xenon plasma arc (PAC; Apollo 95E) for 3 s. Bovine incisors had their buccal surfaces flattened and hybridized. On these surfaces a mold was seated and filled with cement. A 1.5-mm-thick disc of the veneering material was seated over this set for light curing. After storage (24 h/37ºC), specimens (n=10) were sectioned for hardness (KHN) measurements in a micro-hardness tester (50 gf load/ 15 s). Data were submitted to ANOVA and Tukey's test (alpha=0.05). It was observed that the dual cure mode yielded higher hardness compared to the physical mode alone, except for direct light curing with the QTH unit and through Artglass. Higher hardness was observed with QTH compared to PAC, except for Artglass/dual groups, in which similar hardness means were obtained. Low KHN means were obtained with PAC for both Artglass and HeraCeram. It may be concluded that the hardness of resin cements may be influenced by the presence of an indirect restorative material and the type of light-curing unit.


Author(s):  
Sumedha Dewan ◽  
Tarun Kalra ◽  
Manjit Kumar ◽  
Ajay Bansal ◽  
Abhishek Avasthi

Abstract Aim The purpose of this study was to compare and evaluate the flexural strength and modulus of elasticity of three adhesive luting cements as a function of specimen age, effect of storage media, and effect of curing through porcelain. Materials and Method Twenty samples fabricated for self-cure resin-modified glass ionomer cement (GIC; RelyX Luting 2, 3M ESPE, United States) were classified as group 1, whereas 40 samples fabricated for two dual-cure resin cements (20 samples each), Universal Resin Cement (Ammdent, Italy) and Maxcem Elite (Kerr Australia Pty. Ltd.), were classified as groups 2 and 3, respectively. The dual-cure cements were photo-activated using light cure unit with an intensity of 550 mW/cm2 in nine overlapping sections for 20 seconds per section on both sides. A total of 60 samples (20 samples in each group) were fabricated and tested using universal testing machine to compare flexural strength and modulus of elasticity of resin-modified GIC with two dual-cure adhesive resin cements, to determine the influence of storage of the specimens in artificial saliva at 37°C for 24 hours and to determine the influence of curing through porcelain disk of 2 mm thickness on these properties. Results The overall mean flexural strength and modulus of elasticity of resin-modified GIC was less than the dual-cure resin cements. The values reduced for resin-modified GIC when the samples were tested after 24 hours of storage in saliva, whereas an increase in the strength was seen for dual-cure cements. The curing through porcelain disk reduced the properties of dual-cure cements. Maxcem Elite showed better overall mean flexural strength and modulus of elasticity in all the parameters. Conclusion When comparing all three cements, both dual-cure cements showed better flexural strength and modulus of elasticity compared to resin-modified GIC, which indicates their use in cementation of fixed restorations.


2019 ◽  
Vol 13 (02) ◽  
pp. 178-186
Author(s):  
Fabiana S. A. S. Camargo ◽  
Alejandra H. M. González ◽  
Roberta C. B. Alonso ◽  
Vinicius Di Hipólito ◽  
Paulo H. P. D'Alpino

Abstract Objective The aim of the study was to evaluate the physicochemical properties of self-adhesive resin cements associated with hydroxyapatite (HAp) according to the polymerization activation. Materials and Methods Specimens of cements (PermaCem 2.0 [DMG]; MaxCem Elite [Kerr], and RelyX U200 [3M ESPE]) were distributed into three groups: activation mode; self-cured and dual-cured modes; and association or not with HAp powder mode. The pH neutralization was evaluated as a function of time. Flexural strength and elastic modulus were also tested (0.5 mm/min.). The depth of cure was also analyzed using the scraping test (ISO 4049). Infrared spectroscopy was also used to collect the spectra of specimens to evaluate the chemical bonds. Statistical comparisons were conducted at 5% of significance. Results The aggressiveness of the self-adhesive resin cements evaluated varied among the materials with a tendency for neutralization. Self-cure groups exhibited lower pH throughout the entire evaluation when compared with that of the dual-cure ones, irrespective of the addition of HAp. MaxCem Elite when photoactivated was the only cement influenced by the addition of the HAp in terms of mechanical properties. The self-adhesive cements tested presented equivalent depth of cure based on the ISO 4049 requirements, regardless of the evaluated factors. Conclusions Based on the parameters evaluated, the results demonstrated that most of the self-adhesive cements remained unaltered or improved when mixed with HAp, regardless of the activation mode.


2016 ◽  
Vol 41 (2) ◽  
pp. 219-227 ◽  
Author(s):  
E Brambilla ◽  
A Ionescu ◽  
G Cazzaniga ◽  
M Ottobelli

SUMMARYObjectives: The aim of this study was to evaluate the differences in biological and mechanical performances of a silorane-based and a methacrylate-based composite. Another aim was to assess the influence of light-curing time and light-curing intensity on in vitro biofilm formation and flexural strength of the two tested composites.Methods: Experiment 1: 432 specimens obtained from a silorane-based composite and from a standard methacrylate-based composite were divided into six groups and light-cured for 10, 20, 30, 40, 60, or 80 seconds, using one of two light-curing intensities, 400 mW/cm2 or 800 mW/cm2. At 24 hours, a monospecific Streptococcus mutans biofilm adherent to the surfaces of the samples was obtained. Then, a colorimetric technique (MTT assay) was used to evaluate the adherent viable biomass. Two samples per group were observed using confocal laser scanning microscopy. Analysis of variance (ANOVA) and Tukey tests were used to analyze the results (p<0.05). Experiment 2: 192 bar-shaped specimens were obtained and light-cured as in the previous experiment. A three-point bend test using a universal testing machine was performed to obtain flexural strength values. ANOVA and Tukey tests were used to analyze the results (p<0.05).Results: In experiment 1, a highly significant difference (p<0.0001) in biofilm development was shown between silorane-based and methacrylate-based composites. In fact, the silorane-based composite exhibited better biological performance. Significant differences were also found between the two light-curing intensities (p<0.018) and for curing times (p<0.0001): silorane-based composite light-cured for 80 seconds at 800 mW/cm2 light-curing intensity showed the lowest biofilm development. In experiment 2, a significant difference in flexural strength (p<0.0318) was only found between the different composites. Nevertheless, both resin composites showed flexural strength values in accordance with International Organization for Standardization guidelines even after 10 seconds of light-curing time.Conclusions: Silorane-based composite was less prone to biofilm development compared with a methacrylate-based composite. Acceptable flexural strength values for both composites were obtained after 10 seconds of light-curing time.


2010 ◽  
Vol 34 (4) ◽  
pp. 309-312 ◽  
Author(s):  
Priya Subramaniam ◽  
Sapna Kondae ◽  
Kamal Kishore Gupta

The present study evaluated and compared the retentive strength of three luting cements. A total of forty five freshly extracted human primary molars were used in this study. The teeth were prepared to receive stainless steel crowns. They were then randomly divided into three groups, of fifteen teeth each, so as to receive the three different luting cements: conventional glass ionomer, resin modified glass ionomer and adhesive resin. The teeth were then stored in artificial saliva for twenty four hours. The retentive strength of the crowns was determined by using a specially designed Instron Universal Testing Machine (Model 1011). The data was statistically analyzed using ANOVA to evaluate retentive strength for each cement and Tukey test for pair wise comparison. It was concluded that retentive strength of adhesive resin cement and resin modified glass ionomer cement was significantly higher than that of the conventional glass ionomer cement.


2017 ◽  
Vol 16 ◽  
pp. 1-7
Author(s):  
Bruna Genari ◽  
Vicente Castelo Branco Leitune ◽  
João Henrique Macedo Saucedo ◽  
Susana Maria Werner Samuel ◽  
Fabrício Mezzomo Collares

Self-adhesive, dual-polymerizing resin cements require no treatment to the prepared tooth surfaces before cementation. Aim: The aim of this study was to evaluate the influence of curing mode on bond strength (BS) of three cementing systems to bovine dentin. Methods: The buccal enamel surfaces of 50 bovine incisors were removed to expose dentin and to flat the surface. The teeth were divided into five groups (n=10), which consisted of two resin cements (Multilink and Clearfil SA Cement) that were tested in dual- (halogen light for 40 s) and self-cured modes, and a control (RelyX ARC). Two cylinders of resin cements (1.0 mm X 0.75 mm) were prepared on each bonded dentin surface. After 24h at 37oC, resin cylinders were subjected to micro-shear testing in a universal testing machine (4411/Instron - 0.5 mm/min). Data were statistically analyzed by two-way ANOVA, Tukey and Dunnett`s test (5%). Results: Multilink showed higher BS than those observed on Clearfil SA. Light-curing resulted in higher BS for both Multilink and Clearfil SA. When Multilink was light-cured, no significant difference on BS was demonstrated between it and RelyX ARC. Conclusions: The highest BS values were obtained in control group and light-cured Multilink resin cement.


2020 ◽  
Vol 2 (1) ◽  
pp. 45-52
Author(s):  
Ana C. de Assunção Oliveira ◽  
Sandro Griza ◽  
Rafael R. de Moraes ◽  
André L. Faria-e-Silva

Objective:: To investigate the effect of filler content and the time spent before light-curing on mechanical properties of dual-cured cement. Methods:: Experimental dual-cured resin cements were formulated with 60, 65 or 68wt% of filler. The viscosity of experimental cement was measured using a digital viscometer. Bar-shaped specimens (25 x 2 x 2 mm) were fabricated, while the light-curing was started immediately or 5 minutes after the insertion of cement into the mold (n = 7). A three-point bending test was performed and the values of flexural strength and elastic modulus were measured. The Vickers hardness of fractured specimens was measured on the surface of the cement. Data from viscosity were submitted to oneway ANOVA, while the data from mechanical properties were analyzed by two-way ANOVA. All pair-wise comparisons were performed using Tukey’s test (α = 0.05). Results:: The experimental cement with 68wt% of filler showed the highest viscosity and those with 60wt% showed the the lowest viscosity. Irrespective of the time spent before light-curing, the cement with 65wt% of filler presented the highest values of flexural strength and elastic modulus. The addition of 60wt% of filler resulted in the lowest elastic modulus, while 68wt% of filler resulted in lowest flexural strength. Regarding the hardness, the cement with 68wt% of filler showed the highest values, while there was no difference between 60 and 65wt% of filler. Conclusion:: Filler content affected the mechanical properties of the experimental cement and this effect did not depend on the waiting time before the light-curing procedure.


2016 ◽  
Vol 41 (3) ◽  
pp. E83-E92 ◽  
Author(s):  
T Furuichi ◽  
T Takamizawa ◽  
A Tsujimoto ◽  
M Miyazaki ◽  
WW Barkmeier ◽  
...  

SUMMARY The present study determined the mechanical properties and impact-sliding wear characteristics of self-adhesive resin cements. Five self-adhesive resin cements were used: G-CEM LinkAce, BeautiCem SA, Maxcem Elite, Clearfil SA Automix, and RelyX Unicem 2. Clearfil Esthetic Cement was employed as a control material. Six specimens for each resin cement were used to determine flexural strength, elastic modulus, and resilience according to ISO specification #4049. Ten specimens for each resin cement were used to determine the wear characteristics using an impact-sliding wear testing apparatus. Wear was generated using a stainless-steel ball bearing mounted inside a collet assembly. The maximum facet depth and volume loss were determined using a noncontact profilometer in combination with confocal laser scanning microscopy. Data were evaluated using analysis of variance followed by the Tukey honestly significantly different test (α=0.05). The flexural strength of the resin cements ranged from 68.4 to 144.2 MPa; the elastic modulus ranged from 4.4 to 10.6 GPa; and the resilience ranged from 4.5 to 12.0 MJ/m3. The results for the maximum facet depth ranged from 25.2 to 235.9 μm, and volume loss ranged from 0.0107 to 0.5258 mm3. The flexural properties and wear resistance were found to vary depending upon the self-adhesive resin cement tested. The self-adhesive cements tended to have lower mechanical properties than the conventional resin cement. All self-adhesive resin cements, apart from G-CEM LinkAce, demonstrated significantly poorer wear resistance than did the conventional resin cement.


Sign in / Sign up

Export Citation Format

Share Document