depth of cure
Recently Published Documents


TOTAL DOCUMENTS

179
(FIVE YEARS 43)

H-INDEX

33
(FIVE YEARS 3)

Author(s):  
Fatin A. Hasanain

Aims: This work aims to assess the flexural strength and depth of cure of Optishade, Omnichroma and Z350 dental resin composites. Study Design: Experimental Laboratory Study. Methods: To assess flexural strength as per ISO standards, 15 samples of each of the three materials were made (n=5) with the dimensions 25x2x2 mm. They were then subjected to 3 point bending testing on a universal testing machine. To assess depth of cure as per ISO standard, 15 cylindrical samples 4 mm in diameter and 6 mm in height were created (n=5) and scraping test was performed. Results: There was a significant difference between the 3 materials in both flexural strength and depth of cure. Z350 had the lowest depth of cure and the highest flexural strength. Conclusion: Within the limitations of this study, all three tested materials fell within the ISO requirementsfor dental resin compositesfor both flexural strength and depth of cure.


2021 ◽  
Vol 71 ◽  
pp. S40
Author(s):  
Zainab Haji ◽  
Robia Ghafoor
Keyword(s):  

2021 ◽  
Vol 32 (5) ◽  
pp. 77-86
Author(s):  
May Anny Alves Fraga ◽  
Lourenço Correr-Sobrinho ◽  
Mário Alexandre Coelho Sinhoreti ◽  
Talita Malini Carletti ◽  
Américo Bortolazzo Correr

Abstract This in vitro study aimed to evaluate the gaps length and depth of cure of dual-cure bulk-fill resin composites inserted in box-shaped preparations. Box-shaped preparations (4 mm deep) were made in fifteen human third-molars and divided into three groups according to the resin composites (n=5): Dual-cure bulk-fill BulkEZ (BEZ); Dual-cure bulk-fill HyperFIL (HF); and Tetric Evoceram Bulk-fill (TETRIC), as control. Gaps length (%) was evaluated in tooth-restoration interface with micro-computed tomography (µCT). The restorations were sectioned, and the degree of conversion (DC) and Knoop microhardness were evaluated at five depths (0.3, 1, 2, 3, and 4 mm). Microhardness data were statistically evaluated using absolute values (KHN) and relative values (microhardness percentages in relation to top). Gaps length (%) increased in the following order: BEZ=TETRIC<HF. The microhardness percentages in relation to top significantly decreased from 2 mm for TETRIC and 3 mm for HF. BEZ had constant microhardness and DC at all depths, while HF and TETRIC presented a significant decrease on DC at 4 mm. Dual-cure bulk-fill composites did not reduce gaps compared to light-cure bulk-fill, but they can improve depth of cure of bulk-filled restorations.


Author(s):  
Luis Felipe Marques de Resende ◽  
Anderson Catelan ◽  
Kusai Baroudi ◽  
Alan Rodrigo Muniz Palialol ◽  
Alexandre Marques de Resende ◽  
...  

Abstract Objective The effect of different photoinitiators on mechanical properties of experimental composites was evaluated. Materials and Methods Resin composites were formulated by using a blend of bisphenol A-glycidyl and triethylene glycol (50/50 wt%) dimethacrylate monomers, and 65 wt% of barium aluminium silicate and silica filler particles. Photoinitiators used were 0.2% camphorquinone (CQ) and 0.8% co-initiator (DMAEMA); 0.2% phenyl-propanedione and 0.8% DMAEMA; 0.1% CQ + 0.1% phenyl propanedione and 0.8% DMAEMA; 0.42% mono(acyl)phosphine oxide (MAPO); and 0.5% bis(acyl)phosphine oxide (BAPO). Specimens (n = 10) were light cured by using a multiple-emission peak light-emitting diode for 20 seconds at 1,200 mW/cm2 of irradiance and Knoop hardness and plasticization, depth of cure, flexural strength, and elastic modulus were evaluated. Data were statiscally analyzed at significance level of α = 5%. Results Experimental composites containing MAPO and BAPO photoinitiators showed the highest values of flexural strength, elastic modulus, top surface hardness, and lower hardness reduction caused by alcohol compared with CQ. Composites containing CQ and PPD showed similar results, except for depth of cure and hardness of bottom surface. Conclusion BAPO and MAPO showed higher flexural strength, elastic modulus, hardness on top surface, and lower polymer plasticization to CQ.


Polymers ◽  
2021 ◽  
Vol 13 (13) ◽  
pp. 2065
Author(s):  
Guilherme dos Santos Sousa ◽  
Gabriel Felipe Guimarães ◽  
Edilmar Marcelino ◽  
José Eduardo Petit Rodokas ◽  
Arilson José de Oliveira Júnior ◽  
...  

The literature has shown that there is no consensus regarding the best resin composite photoactivation protocol. This study evaluated the efficiency of the conventional, soft-start, pulse-delay and exponential protocols for photoactivation of resin composites in reducing the shrinkage stress and temperature variation during the photopolymerisation. The photoactivation processes were performed using a photocuring unit and a smartphone app developed to control the irradiance according each photoactivation protocol. These photoactivation methods were evaluated applying photoactivation energies recommended by the resins manufactures. Three brands of resin composites were analysed: Z-250, Charisma and Ultrafill. The cure effectiveness was evaluated through depth of cure experiments. All results were statistically evaluated using one-way and multi-factor analysis of variance (ANOVA). The use of exponential and pulse-delay methods resulted in a significant reduction of the shrinkage stress for all evaluated resins; however, the pulse-delay method required too long a photoactivation time. The increases on the temperature were lower when the exponential photoactivation was applied; however, the temperature variation for all photoactivation protocols was not enough to cause damage in the restoration area. The evaluation of the depth of cure showed that all photoactivation protocols resulted in cured resins with equivalent hardness, indicating that the choice of an alternative photoactivation protocol did not harm the polymerisation. In this way, the results showed the exponential protocol as the best photoactivation technique for practical applications.


Author(s):  
Alperen Değirmenci ◽  
Dilber Bilgili Can

OBJECTIVE: The aim of this study was to investigate the effect of preheating three bulk-fill and one conventional composite resin on the Vickers microhardness and depth of cure of these composites. METHODS: In this study, three bulk-fill composites-SDR Plus (SDR), Estelite BULK FILL Flow (EST), Admira® Fusion x-tra (AFX), and one conventional composite resin G-ænial POSTERIOR (GP) were used as the control group. The samples were obtained at room temperature (24°C) and at 55°C in T2 mode after being placed in a heating device for 10 minutes. The samples were divided into eight groups (n=10) according to the type of material and heating process that was utilized (preheated and nonheated). All samples were tested with a Vickers microhardness (VHN) tester on the bottom and top surfaces. The first measurements were obtained at baseline; the second set of measurements was performed after the samples were stored in distilled water at 37°C for 24 hours. The depth of cure was calculated using a bottom/top hardness ratio of measurements. Statistical analysis was performed utilizing the SPSS V23 and Shapiro-Wilk tests. Lastly, the Duncan test was used for multiple comparisons (p<0.05). RESULTS: While the VHN increased after the preheating procedure in bulk-fill composites, it decreased in GP. There was no difference between the baseline and the 24-hour VHN values in SDR and GP. After 24 hours, while the VHN of EST increased, the VHN of AFX decreased. There was no difference between the hardness ratios of the AFX and EST samples (p<0.001) and hardness ratios were greater than GP and SDR. CONCLUSION: When comparing the baseline and the 24-hour values, the VHN depended on the type of materials. Sufficient curing depth was obtained in all groups with a thickness of 2mm.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Raju Raju ◽  
Ginu Rajan ◽  
Paul Farrar ◽  
B. Gangadhara Prusty

AbstractFibre-reinforced dental composites are proven to have superior mechanical properties in comparison with micro/nano/hybrid filled composites. However, the addition of small quantities of short glass fibres could affect the dimensional stability of the restoration both during initial stages as well as through the life of the restoration. This in-vitro study aims at evaluating the physical properties of short S-Glass reinforced flowable dental composites. Two S-Glass short fibre-particulate reinforced (5 wt% of aspect ratios 50 and 70) and one particulate only reinforced flowable dental composites were prepared with UDMA-TEGDMA based dental monomer systems. Samples were photopolymersied for 60 s and stored in distilled water at 37 °C for 24 h before testing. Depth of cure (through-thickness microhardness), volumetric shrinkage (Archimedes technique), polymerisation stress (cantilever based tensometer), curing exotherm (thermocouple), water sorption and solubility (ISO 4049) and thermal expansion coefficient (dilatometer) were determined. The test results were statistically analysed using one-way ANOVA (p < 0.05). Depth of cure increased by 41%, volumetric shrinkage increased by 8.3%, shrinkage stress increased by 37.6%, exotherm increased by 20.2%, and thermal expansion reduced by 6.4% while water sorption and solubility had a negligible effect with the inclusion of short glass fibres. The study demonstrates that within the same organic resin system and quantity, a small replacement of fillers with short fibres could significantly affect the dimensional stability of the composite system. In conjunction with mechanical properties, this study could help clinicians to gain confidence in fibre reinforced dental composite restorative system.


2021 ◽  
Vol 32 (1) ◽  
pp. 78-84
Author(s):  
Mateus Garcia Rocha ◽  
Jean-François Roulet ◽  
Mario Alexandre Coelho Sinhoreti ◽  
Américo Bortolazzo Correr ◽  
Dayane Oliveira

Abstract The objective of this study was to evaluate the effect of the exposure reciprocity law of a multi-wave light-emitting diode (LED) on the light transmittance (LT), depth of cure (DOC) and degree of conversion in-depth (DC) of a bulk fill composite. A bulk fill composite (EvoCeram® bulk fill, Ivoclar Vivadent) was photoactivated using the multi-wave LED (VALO™ Cordless, Ultradent). The LED was previously characterized using a spectrophotometer to standardize the time of exposure when using the Standard or Xtra-Power modes with the same radiant exposure of 20J/cm2. LT was evaluated through samples of the bulk fill composite every millimeter till 4 mm in-depth. DOC was evaluated according to the ISO 4049. DC of the central longitudinal cross-section from each sample of the DOC test was mapped using FT-NIR microscopy. Data were statistically analyzed according to the experimental design (α=0.05; ß=0.2). The radiant exposure in the violet wavelength range for Standard and Xtra-Power was 4.5 and 5.0 J/cm2, respectively; for the blue wavelength range the radiant exposure for Standard and Xtra-Power was 15.5 and 15.0 J/cm2, respectively. There was no statistical difference in the DOC using Standard or Xtra-Power light-curing modes, but the DOC was lower than the claimed by the manufacturer (4 mm). The DC was not significantly affected by the light-curing mode up to 4 mm in depth (p>0.05). According to exposure reciprocity law, the reduction in exposure time using the same radiant exposure did not affect the depth of cure of the bulk fill composite.


Sign in / Sign up

Export Citation Format

Share Document