scholarly journals A new method for hardness determination from depth sensing indentation tests

1996 ◽  
Vol 11 (12) ◽  
pp. 2964-2967 ◽  
Author(s):  
J. Gubicza ◽  
A. Juhász ◽  
J. Lendvai

A new semiempirical formula is developed for the hardness determination of the materials from depth sensing indentation tests. The indentation works measured both during loading and unloading periods are used in the evaluation. The values of the Meyer hardness calculated in this way agree well with those obtained by conventional optical observation, where this latter is possible. While the new hardness formula characterizes well the behavior of the conventional hardness number even for the ideally elastic material, the mean contact pressure generally used in hardness determination differs significantly from the conventional hardness number when the ideally elastic limiting case is being approached.

2004 ◽  
Vol 19 (8) ◽  
pp. 2487-2497 ◽  
Author(s):  
Michelle L. Oyen ◽  
Robert F. Cook ◽  
John A. Emerson ◽  
Neville R. Moody

A viscous-elastic-plastic indentation model was extended to a thin-film system, including the effect of stiffening due to a substrate of greater modulus. The system model includes a total of five material parameters: three for the film response (modulus, hardness, and time constant), one for the substrate response (modulus), and one representing the length-scale associated with the film-substrate interface. The substrate influence is incorporated into the elastic response of the film through a depth-weighted elastic modulus (based on a series sum of film and substrate contributions). Constant loading- and unloading-rate depth-sensing indentation tests were performed on polymer films on glass or metal substrates. Evidence of substrate influence was examined by normalization of the load-displacement traces. Comparisons were made between the model and experiments for indentation tests at different peak load levels and with varying degrees of substrate influence. A single set of five parameters was sufficient to characterize and predict the experimental load-displacement data over a large range of peak load levels and corresponding degrees of substrate influence.


2010 ◽  
Vol 662 ◽  
pp. 53-76 ◽  
Author(s):  
Feodor M. Borodich

An overview of development of indentation techniques and connections between contact mechanics and methods of extracting mechanical characteristics from indentation data is given. Observed disagreements between the experimental observations and the models of indentation are discussed. It is shown that this disagreement is often caused by violation of hypotheses that are used in the formulation of the appropriate boundary-value contact problems and strictly speaking one cannot apply directly the solutions of Hertz type contact problems to indentation tests employing the sharp indenters. It is shown that commonly used experimental test involving sharp pyramidal and conical indenters may be applied to study plastic properties of materials while this approach is not very accurate for estimations of elastic modulus of the test solid. The recently proposed by Borodich and Galanov non-direct method that employs data of elastically loading of a spherical indenter is described. It is argued that the non-direct method can be used for determination of both the work of adhesion and elastic modulus of the tested material.


2007 ◽  
Vol 340-341 ◽  
pp. 555-562 ◽  
Author(s):  
J. Lin ◽  
J. Luo ◽  
Trevor A. Dean

A novel optimization approach is proposed to extract mechanical properties of a power law material from its given experimental nano-indentation P-h curves. A set of equations have been established to relate the P-h curve to mechanical properties, E, σ y and n, of a material. Using the proposed optimization approach, convergence studies were carried out for the determination of the mechanical properties of materials. It was found that the mechanical properties of an elastic-plastic material usually cannot be uniquely determined using a single loading and unloading P-h curve. Thus a technique has also been developed to determine the material properties from indentation p-h curves using indenters with two different angles. This enables the mechanical properties of materials to be uniquely determined.


1996 ◽  
Vol 75 (05) ◽  
pp. 772-777 ◽  
Author(s):  
Sybille Albrecht ◽  
Matthias Kotzsch ◽  
Gabriele Siegert ◽  
Thomas Luther ◽  
Heinz Großmann ◽  
...  

SummaryThe plasma tissue factor (TF) concentration was correlated to factor VII concentration (FVIIag) and factor VII activity (FVIIc) in 498 healthy volunteers ranging in age from 17 to 64 years. Immunoassays using monoclonal antibodies (mAbs) were developed for the determination of TF and FVIIag in plasma. The mAbs and the test systems were characterized. The mean value of the TF concentration was 172 ± 135 pg/ml. TF showed no age- and gender-related differences. For the total population, FVIIc, determined by a clotting test, was 110 ± 15% and the factor VIlag was 0.77 ± 0.19 μg/ml. FVII activity was significantly increased with age, whereas the concentration demonstrated no correlation to age in this population. FVII concentration is highly correlated with the activity as measured by clotting assay using rabbit thromboplastin. The ratio between FVIIc and FVIIag was not age-dependent, but demonstrated a significant difference between men and women. Between TF and FVII we could not detect a correlation.


1966 ◽  
Vol 16 (01/02) ◽  
pp. 038-050 ◽  
Author(s):  
Ulla Hedner ◽  
Inga Marie Nilsson ◽  
B Robertson

SummaryThe plasminogen content was determined by a casein method in plasma and serum from 20 normal volunteers. The mean plasminogen content was found to be 10.1 ACU (the arbitrary caseinolytic unit defined in such a way that using a 3% casein solution and a digestion time of 20 min. at 37°C, 10 ACU gave an extinction of 0.300). No difference between serum and plasma regarding the plasminogen content was found.Plasminogen was determined in drained and drained plus washed clots prepared from 2 ml plasma. The highest values found in the drained clots were 0.9 ACU/clot and 0.2 ACU/clot in the drained plus washed clots.Plasminogen was also determined in drained and drained plus washed clots prepared from plasma with added purified plasminogen. The plasminogen was recovered in the washing fluid. According to these tests, then, purified added plasminogen is washed out of the clots.The plasminogen content of 20 thrombi obtained post mortem was also determined. The mean value was found to be 0.7 ACU/cm thrombus. Judging from our results, the “intrinsic clot lysis theory” is not the main mechanism of clot dissolution.


1973 ◽  
Vol 72 (4) ◽  
pp. 714-726 ◽  
Author(s):  
A. Burger ◽  
B. Miller ◽  
C. Sakoloff ◽  
M. B. Vallotton

ABSTRACT An improved method for the determination of serum triiodothyronine (T3) has been developed. After addition of a tracer amount of the hormone, T3 was extracted from 1 ml serum under conditions of pH and ionic strength which favoured T3 extraction (89%) over thyroxine (T4) extraction (58%). Chromatography of the extracted material on Sephadex LH-20 separated T3 completely from residual T4. The T3 eluate was dried, then re-dissolved in 0.5 ml NaOH 0.04 n. To 0.2 ml duplicate aliquots, a standard amount of TBG was added for the competitive protein analysis. After one hour incubation at 4°C, separation of bound from free T3 was achieved on small Sephadex G-25 columns. Overall recovery was 67 ± 10.8% and correction for the loss was made. The solvent blank was 37 ± 27 (sd) ng/100 ml. Accuracy of measurement of known quantities of T3 added to serum was 98.4%. The coefficient of variation within the assay was 6.2% and between the assays it was 11.4%. The limit of detection (0.1 ng) corresponded to a concentration of 25 ng/100 ml. T4 added to serum did not interfere with T3 determination until high non-physiological values were reached. The mean ± sd serum T3 in 54 euthyroid subjects was 153 ± 58 ng/100 ml and in 24 hyperthyroid patients it was 428 ±186 ng/100 ml; 4 out of the 24 hyperthyroid values were within 2 sd of the mean euthyroid group. All the values found in the euthyroid group were well above the limit of detection of the method.


2010 ◽  
Vol 35 (4) ◽  
pp. 543-550 ◽  
Author(s):  
Wojciech Batko ◽  
Bartosz Przysucha

AbstractAssessment of several noise indicators are determined by the logarithmic mean <img src="/fulltext-image.asp?format=htmlnonpaginated&src=P42524002G141TV8_html\05_paper.gif" alt=""/>, from the sum of independent random resultsL1;L2; : : : ;Lnof the sound level, being under testing. The estimation of uncertainty of such averaging requires knowledge of probability distribution of the function form of their calculations. The developed solution, leading to the recurrent determination of the probability distribution function for the estimation of the mean value of noise levels and its variance, is shown in this paper.


Sign in / Sign up

Export Citation Format

Share Document