scholarly journals PERFORMANSI INSTALASI PENGOLAH AIR LIMBAH TAMBAK SUPERINTENSIF

2017 ◽  
Vol 12 (2) ◽  
pp. 95 ◽  
Author(s):  
Rachman Syah ◽  
Mat Fahrur ◽  
Hidayat Suryanto Suwoyo ◽  
Makmur Makmur

Pengolahan air buangan tambak superintensif (TSI) adalah usaha untuk mengurangi beban bahan pencemar yang terkandung di dalam air buangan TSI sehingga aman dan tidak membahayakan saat dibuang ke lingkungan. Penelitian ini bertujuan untuk mengevaluasi desain dan performansi Instalasi Pengolahan Air Limbah (IPAL) dalam memperbaiki kualitas air buangan TSI sebelum dibuang ke badan air. IPAL terdiri atas kolam sedimentasi, dua kolam aerasi, dan satu kolam penampungan. Ke dalam kolam penampungan ditebari ikan mujair serta rumput laut Gracilaria sp. yang dibudidayakan dengan metode long line, berfungsi sebagai biokontrol. Sampel air diambil di bagian inlet IPAL, oulet kolam sedimentasi atau inlet kolam aerasi-1, outlet kolam aerasi-1 atau inlet kolam aerasi-2, outlet kolam aerasi-2 atau inlet kolam penampungan, serta outlet kolam penampungan, setiap dua minggu selama 105 hari pemeliharaan. Parameter yang diukur adalah total padatan tersuspensi (TSS), total amonia nitrogen (TAN), nitrit, nitrat, fosfat, bahan organik terlarut (BOT), dan biological oxygen demand (BOD-5). Spesifikasi teknis IPAL yang diamati meliputi ukuran dan volume IPAL, volume dan waktu tinggal air buangan tambak, dan efisiensi kinerja IPAL, serta rasio volume IPAL dan volume total air tambak. Hasil penelitian menunjukkan bahwa IPAL dapat mengurangi beban bahan pencemar dengan tingkat efisiensi antara 53,1%-99,4%; namun masih diperlukan peningkatan kapasitas dalam mengurangi konsentrasi BOT. IPAL menghasilkan efisiensi yang tinggi terhadap TSS, TAN, nitrit, Total Nitrogen (TN), dan fosfat. Rasio volume IPAL dan volume air tambak 30:70 dengan waktu tinggal minimal lima hari, dapat dijadikan acuan dalam pembangunan IPAL tambak superintensif.A wastewater treatment plant (WTP) in a super-intensive shrimp farm is used to reduce organic matters contained in super-intensive shrimp farm effluent. Through the WTP, the waste water from shrimp facilities can safely and harmlessly be released to the receiving environments. The aims of this study were to evaluate the design and performance of a WTP in reconditioning waste water released from a super-intensive shrimp farm prior to release to water bodies. The WTP was made of a series of sedimentation pond, two aeration ponds, and one reservoir or equalitation pond. The tilapia fish and seaweed, Gracilaria sp., were stocked in the equalitation pond where the seaweed was cultured using long line method; these organisms were used as bio-control. Water samples were collected fortnightly during 105 days of culturing duration from the WTP inlet, outlet of sedimentation pond or at inlet of the first aeration pond; outlet of the first aeration pond or inlet of the second aeration pond, outlet of the second aeration pond or inlet of equalitation pond and the outlet of equalitation pond. The measured variables were total suspended solid (TSS), total ammonia nitrogen (TAN), nitrite, nitrate, phosphate, total organic matters (TOM), and five days biological oxygen demand (BOD5). The evaluated technical performances of the plant were its size and volume; volume and retention time of effluent, efficiency of WTP performance and volume ratios of the WTP and total volume of shrimp pond. The results of the study indicated that the WTP was able to reduce concentrations of nutrients and solids in effluent by 53.1%-99.4% of efficiency. However, its capacity need to be increased due to reducing concentrations of TOM. The WTP was highly efficient in reducing the concentrations of TSS, TAN, nitrite, total N, and phosphate. The volume ratios between the plant and pond waters were 30:70 with minimum retention time five which days could be proposed for wastewater treatment pond for super-intensive shrimp ponds.

2005 ◽  
Vol 51 (11) ◽  
pp. 159-166
Author(s):  
E. Ubay-Cokgor ◽  
C.W. Randall ◽  
D. Orhon

In this paper, the performance of the Tyson Foods wastewater treatment plant with an average flow rate of 6500 m3/d was evaluated before and after upgrading of the treatment system for nitrogen removal. This study was also covered with an additional recommendation of BIOWINTM BNR program simulation after the modification period to achieve an additional nutrient removal. The results clearly show that the upgrading was very successful for improved nitrogen removal, with a 57% decrease on the total nitrogen discharge. There also were slight reductions in the discharged loads of biological oxygen demand, total suspended solids, ammonium and total phosphorus with denitrification, even though the effluent flow was higher during operation of the nitrogen removal configuration.


2011 ◽  
Vol 64 (12) ◽  
pp. 2376-2380 ◽  
Author(s):  
Suwasa Kantawanichkul ◽  
Wanida Duangjaisak

The experiments were conducted in four concrete laboratory scale free water surface constructed wetland units 1 m wide, 1.5 m long and 0.8 m deep. Paddy field soil was added to a depth of 0.4 m and rice seedlings (Oryza sativa L.) were transplanted into the units at a density of 25 plants/m2. Domestic wastewater collected from Chiang Mai University was applied into each unit via two different modes to evaluate suitable conditions for wastewater treatment and rice yield. In the first experiment, the wastewater was fed intermittently (7 h/day) with a hydraulic loading rate of 2, 4, 6 and 8 cm/day. The maximum removal efficiencies for chemical oxygen demand, biological oxygen demand, total kjedahl nitrogen and suspended solids were only 49.1, 58.7, 64.0 and 59.4%, respectively, due to the short hydraulic retention time for the biodegradation of organic substances. In the second experiment, the wastewater in each unit was inundated to a depth of 15 cm for 10, 15, 20 and 25 days in each unit and then drained and re-flooded. Removal efficiencies of chemical oxygen demand, biological oxygen demand, total kjedahl nitrogen and suspended solids were greater than in the first experiment especially at the 25 day retention time and except for suspended solids met the Thai national effluent standard. The study revealed that apart from wastewater treatment, wastewater can replace natural water to grow rice in the dry season or throughout the year. Moreover, nutrients in wastewater can be a substitute for chemical fertilizers. Rice grain production was 4,700 kg/ha and only 6% less than the production from the conventional paddy field.


2013 ◽  
Vol 7 (1) ◽  
pp. 44-49
Author(s):  
Shaima Fakhry Jasime ◽  
Khalid Falih Hassan ◽  
Waleed Husain Salman

Bacillus apiarus, Bacillus filicolonicus and Bacillus laterosporus were used to degrade organic pollutants from final discharge of Al Dura wastewater treatment plant in Baghdad and reduce their concentrations by measuring Chemical Oxygen Demand (COD), Total Organic Carbon (TOC), Total Nitrogen (TN) and Total Phosphorus (TP) in laboratories conditions of 25o c, pH 5.8-6.8 in batch culture system and 18hr period treatment, the bacteria Bacillus apiarus, Bacillus filicolonicus and Bacillus laterosporus showed ability to reduce COD concentration by(82, 88.5, 94)% and TOC concentration by (73, 82 ,84)% and TN concentration reduced by (86, 91, 81)% in 18 hr period treatment with highly significant differences P<0.01 for all bacterial treatments, the bacteria in the current study showed high ability to reduce TP concentration by 100% with highly significant differences P<0.01 for all bacterial treatments in 18hr period treatment.


Author(s):  
Fidyan Hifzhani ◽  
Syarifudin A. ◽  
Arifin Arifin

Abstract : Effectiveness Of Rbc System On Wwtp (Wastewater Treatment Plant) Pekapuran Raya Wt (Wastewater Treatment) Local Company Banjarmasin To Reduce Bod Contents. Increased household activities lead to increase the volume of waste generated over time. Annually, the household waste volume increases 5 million m3. WT Local Company Banjarmasin is a wastewater management company that performs domestic sewage treatment (feces) Banjarmasin city. Application of waste treatment technology on WWTP Banjarmasin is RBC system. This study aimed to determine the effectiveness of RBC system on WT Local Company Banjarmasin to reduce BOD (Biological Oxygen Demand). This type of study was analytic. The study design used one group pretest posttest design. The place of study was WWTP Pekapuran Raya WT Local Company Banjarmasin 2017. The study population was wastewater from inlet and outlet pipes. Sample was wastewater taken inlet and outlet pipe tanks. The result showed BOD (Biological Oxygen Demand) contents in the wastewater sample before it was processed of 130.97 mg/L, 116.98 mg/L, and 193.45 mg/l. After it was processed of 13.81 mg/L, 20.138 mg/L, and 30.216 mg/L. The effectiveness of RBC system on the reduce of BOD (Biological Oxygen Demand) in WWTP Pekapuran Raya WT Local Company Banjarmasin was 89.37% for first day, 80.51% for second day and 83.73% for the third day. There were differences before and after BOD (Biological Oxygen Demand) treated by RBC in WWTP Pekapuran Raya WT Local Company Banjarmasin. Keywords: WWTP; RBC system; BOD.


Author(s):  
Vasile Mihai CRIŞAN ◽  
Carmen PUIA

The Wastewater Treatment Plant of Zalau, Salaj county, Romania was designed to treat approximately 18.425 m³ wastewater per day, and in order to follow the discharge parameters for the chemical oxygen demand indicators (COD), biological oxygen demand (BOD) and suspension solids (SS), the aeration basins have been conceived to function as a unit on nitrification and denitrification. The concentration of the dissolved oxygen is being maintained at the level of 1 mg/l, on the aeration basin, so as to prevent the growth of autotrophic bacteria and nitrification process. Existing Wastewater Treatment Plant has been designed for a population equivalent of 50.500 people and the aim of the project is to enlarge treatment plant capacity to 90.900 population equivalent and reach the maximum effluent quality. The Wastewater Treatment Plant, is built only for the nitrification process, reduces the nitrogenous chemical compounds but not the phosphor – nitrogen compounds. The exclusive use of nitrification process in the WWTP leads to an overloading of the stream waters with manure.


2016 ◽  
Vol 9 (2) ◽  
Author(s):  
Dinda Rita K. Hartaja ◽  
Imam Setiadi

Generally, wastewater of nata de coco industry contains suspended solids and COD were high, ranging from 90,000 mg / l. The high level of of the wastewater pollutants, resulting in nata de coco industry can not be directly disposed of its wastewater into the environment agency. Appropriate technology required in order to process the waste water so that the treated water can meet the environmental quality standards that are allowed. Designing the waste water treatment plant that is suitable and efficient for treating industrial wastewater nata de coco is the activated sludge process. Wastewater treatment using activated sludge process of conventional (standard) generally consists of initial sedimentation, aeration and final sedimentation.Keywords : Activated Sludge, Design, IPAL


2008 ◽  
Vol 57 (8) ◽  
pp. 1287-1293 ◽  
Author(s):  
A. Jobbágy ◽  
G. M. Tardy ◽  
Gy. Palkó ◽  
A. Benáková ◽  
O. Krhutková ◽  
...  

The purpose of the experiments was to increase the rate of activated sludge denitrification in the combined biological treatment system of the Southpest Wastewater Treatment Plant in order to gain savings in cost and energy and improve process efficiency. Initial profile measurements revealed excess denitrification capacity of the preclarified wastewater. As a consequence, flow of nitrification filter effluent recirculated to the anoxic activated sludge basins was increased from 23,000 m3 d−1 to 42,288 m3 d−1 at an average preclarified influent flow of 64,843 m3 d−1, Both simulation studies and microbiological investigations suggested that activated sludge nitrification, achieved despite the low SRT (2–3 days), was initiated by the backseeding from the nitrification filters and facilitated by the decreased oxygen demand of the influent organics used for denitrification. With the improved activated sludge denitrification, methanol demand could be decreased to about half of the initial value. With the increased efficiency of the activated sludge pre-denitrification, plant effluent COD levels decreased from 40–70 mg l−1 to &lt; 30–45 mg l−1 due to the decreased likelihood of methanol overdosing in the denitrification filter


2012 ◽  
Vol 7 (1) ◽  
Author(s):  
S. S. Fatima ◽  
S. Jamal Khan

In this study, the performance of wastewater treatment plant located at sector I-9 Islamabad, Pakistan, was evaluated. This full scale domestic wastewater treatment plant is based on conventional activated sludge process. The parameters which were monitored regularly included total suspended solids (TSS), mixed liquor suspended solids (MLSS), mixed liquor volatile suspended solids (MLVSS), biological oxygen demand (BOD), and chemical oxygen demand (COD). It was found that the biological degradation efficiency of the plant was below the desired levels in terms of COD and BOD. Also the plant operators were not maintaining consistent sludge retention time (SRT). Abrupt discharge of MLSS through the Surplus Activated sludge (SAS) pump was the main reason for the low MLSS in the aeration tank and consequently low treatment performance. In this study the SRT was optimized based on desired MLSS concentration between 3,000–3,500 mg/L and required performance in terms of BOD, COD and TSS. This study revealed that SRT is a very important operational parameter and its knowledge and correct implementation by the plant operators should be mandatory.


2017 ◽  
Vol 77 (1) ◽  
pp. 70-78 ◽  
Author(s):  
Yanjun Mao ◽  
Xie Quan ◽  
Huimin Zhao ◽  
Yaobin Zhang ◽  
Shuo Chen ◽  
...  

Abstract The activated sludge (AS) process is widely applied in dyestuff wastewater treatment plants (WWTPs); however, the nitrogen removal efficiency is relatively low and the effluent does not meet the indirect discharge standards before being discharged into the industrial park's WWTP. Hence it is necessary to upgrade the WWTP with more advanced technologies. Moving bed biofilm processes with suspended carriers in an aerobic tank are promising methods due to enhanced nitrification and denitrification. Herein, a pilot-scale integrated free-floating biofilm and activated sludge (IFFAS) process was employed to investigate the feasibility of enhancing nitrogen removal efficiency at different hydraulic retention times (HRTs). The results showed that the effluent chemical oxygen demand (COD), ammonium nitrate (NH4+-N) and total nitrogen (TN) concentrations of the IFFAS process were significantly lower than those of the AS process, and could meet the indirect discharge standards. PCR-DGGE and FISH results indicated that more nitrifiers and denitrifiers co-existed in the IFFAS system, promoting simultaneous nitrification and denitrification. Based on the pilot results, the IFFAS process was used to upgrade the full-scale AS process, and the effluent COD, NH4+-N and TN of the IFFAS process were 91–291 mg/L, 10.6–28.7 mg/L and 18.9–48.6 mg/L, stably meeting the indirect discharge standards and demonstrating the advantages of IFFAS in dyestuff wastewater treatment.


Sign in / Sign up

Export Citation Format

Share Document