scholarly journals Predictive relay-vector stator current control in induction electric drive with matrix direct frequency converter

2010 ◽  
Vol 0 (2) ◽  
pp. 17-25
Author(s):  
A. A. Kolesnikov ◽  
A.G. Lohmatov
2019 ◽  
Vol 124 ◽  
pp. 01037 ◽  
Author(s):  
V. N. Meshcheryakov ◽  
D. V. Lastochkin ◽  
Z.M. Shakurova ◽  
S. Valtchev

This paper discusses the wound rotor induction motor and variable-frequency drive (VFD) that regulates the stator voltage frequency. The stator and rotor windings are connected to a common electrical circuit. The slip energy of the motor goes to the DC link and feeds the stator winding of the motor. The block diagram of the electric drive, the equivalent circuit and the basic characteristic of the cascade VFD are considered. It is shown that the energy-saving mode with a minimum ratio “stator current/torque” is achieved at an angle between vectors of the stator current and the excitation current at the level of 45 degrees. The experimental static mechanical characteristics of the electric drive were obtained. These characteristics provide a limitation of the starting torque.


Vestnik IGEU ◽  
2019 ◽  
pp. 49-61 ◽  
Author(s):  
V.N. Meshcheryakov ◽  
A.S. Belousov

High overload capacity and ability to control speed in a wide range are important requirements for modern electric drives. Introduction of a low-power adjustable two-phase electric drive with these properties into me-chanical devices is limited by the frequency converter function to convert a three-phase network into a two-phase one when the unit power of such mechanisms increases. Previous studies have shown that it is possible to use a standard frequency converter with a three-phase bridge voltage inverter applying a new control algorithm based on space-vector PWM. When PWM is used, the switching frequency of the key inverter elements remains quite high, strictly specified, non-amenable to reduction without degrading the harmonic composition. The goal of this work is to develop an algorithm for two-phase electric drive control that would reduce the number of switching operations of the switch elements of a three-phase inverter with-out increasing the deviations of the instantaneous values of the phase currents from the reference sine curve. The study employed provisions of the theory of automatic control, the theory of electric drive and methods of mathematical modeling. The simulation object was the control system of a two-phase motor; the elements of the Matlab Simulink software package were used. An algorithm has been proposed for operating a three-phase inverter of a two-phase electric drive system. The difference of the algorithm from the well-known control system of a standard bridge inverter with space vector PWM consists in using phase current control relays and dividing the period of sinusoidal phase currents into four sections ensuring a decrease in the number of switching operations of the inverter switch elements when the maximum instantaneous deviations of current values from a sinusoidal reference are equal, the starting torque of the motor is stabilized and the speed control is smooth. The results show that with an equal maximum deviation of the instantaneous current values from a given sinusoidal value, the number of switching operations of the inverter switch elements in the proposed system is smaller than in the known analogues. The electric drive system ensures the start of a two-phase motor with stabilization of the starting torque under increased load. The considered system of variable frequency control with current control relays can be used for two-phase electric drives of mechanical devices and household electric appliances and is promising as a substitute for less cost-effective single-phase and capacitor motors.


Energies ◽  
2019 ◽  
Vol 12 (19) ◽  
pp. 3713
Author(s):  
Daniel R. Ramirez ◽  
Cristina Martin ◽  
Agnieszka Kowal G. ◽  
Manuel R. Arahal

In this paper, a fuzzy-logic based operator is used instead of a traditional cost function for the predictive stator current control of a five-phase induction machine (IM). The min-max operator is explored for the first time as an alternative to the traditional loss function. With this proposal, the selection of voltage vectors does not need weighting factors that are normally used within the loss function and require a cumbersome procedure to tune. In order to cope with conflicting criteria, the proposal uses a decision function that compares predicted errors in the torque producing subspace and in the x-y subspace. Simulations and experimental results are provided, showing how the proposal compares with the traditional method of fixed tuning for predictive stator current control.


2015 ◽  
Vol 792 ◽  
pp. 8-14
Author(s):  
Gennady Petrovich Kornilov ◽  
Ildar Ravil’evich Abdulveleev ◽  
Timur Rifkatovich Khramshin

The article presents the comparative analysis of influence frequency regulated electric drive and current electric drive to harmonic structure of voltage of power grid. There was obtained the dependence of total harmonic distortion (THD) of curve on loading power for 2 types of valve converters. The effectiveness is shown in use of filter compensating device, connected at low side of converting transformer. There were defined the ranges of filter adjusting for improving THD of voltage curve. The described solutions are performed by the structural modeling method of Simulink packet in Matlab environment.


2014 ◽  
Vol 698 ◽  
pp. 131-135 ◽  
Author(s):  
V. Timoshkin ◽  
A. Glazyrin ◽  
L. Kozlova

This article describes the main advantages and disadvantages of electric drive TVR-IM compared with a frequency converter. The necessity to use electric drives TVR-IM and angular velocity observers to solve technological problems is substantiated. Promising directions in the field of constructing closed-loop by the speed observer systems TVR-IM are shown.


Energies ◽  
2020 ◽  
Vol 13 (11) ◽  
pp. 3009
Author(s):  
Pawel Ewert

This article presents the effectiveness of bispectrum analysis for the detection of the rotor unbalance of an induction motor supplied by the mains and a frequency converter. Two diagnostic signals were analyzed, as well as the stator current and mechanical vibrations of the tested motors. The experimental tests were realized for two low-power induction motors, with one and two pole pairs, respectively. The unbalance was modeled using a test mass mounted on a specially prepared disc and directly on the rotor and the influence of this unbalance location was tested and discussed. The results of the bispectrum analysis are compared with results of Fourier transform and the effectiveness of unbalance detection are discussed and compared. The influence of the registration time of the analyzed signal on the quality of fault symptom analyses using both transforms was also tested. It is shown that the bispectrum analysis provides an increased number of fault symptoms in comparison with the classical spectral analysis as well as it is not sensitive to a shorter registration time of the diagnostic signals.


Sign in / Sign up

Export Citation Format

Share Document