scholarly journals Less Invasive Surgical Procedures Using Narrow-Diameter Implants: A Prospective Study in 20 Consecutive Patients

2015 ◽  
Vol 41 (6) ◽  
pp. 693-699 ◽  
Author(s):  
France Emmanuelle Lambert ◽  
Geoffrey Lecloux ◽  
Charlotte Grenade ◽  
Alice Bouhy ◽  
Marc Lamy ◽  
...  

Narrow-diameter implants (NDIs) are increasingly produced and used in implant dentistry, especially since the introduction of new, more resistant materials. The objective of the present study was to evaluate the clinical performance of NDIs (3.3 mm) placed in thin alveolar crests. Twenty consecutive patients needing implant-supported fixed partial dentures and presenting an alveolar thickness ≤6 mm were treated with 1 or several NDIs. The surgical protocol was chosen according to the clinical situation: (1) flapless, (2) mini-cervical flap, (3) wide flap, (4) wide flap + guided bone regeneration (GBR). Implants were immediately loaded if the primary stability was higher than 20 Ncm. Implant survival and success, prosthodontic success rates, and patient-centered outcomes were evaluated after a follow-up period of 1 year. A total of 39 implants were placed in 20 patients, 12 and 27 implants in the anterior regions and in the posterior mandible, respectively. All but 1 implant reached an insertion torque higher than 20 Ncm and were loaded within 48 hours. The implant survival and success rates both reached 94.7%. The need for GBR was avoided in 60% of the implant sites. The mean peri-implant bone remodeling after a follow-up period of 1 year was −0.35 mm at the implant level. Peri-implant bone remodeling was higher in the posterior region, when the alveolar crest was thinner than 4 mm and GBR was required in addition. In conclusion, use of NDIs to restore partial edentation in sites with limited horizontal thickness seems to be an effective treatment option that prevented GBR in the majority of the present cases. Immediate provisionalization of NDIs does not seem to impair the results.

Author(s):  
Marco Tallarico ◽  
Aurea Maria Immacolata Lumbau ◽  
Silvio Mario Meloni ◽  
Irene Ieria ◽  
Chang-Joo Park ◽  
...  

Abstract Objective The purpose of the present prospective, case-series study was to report implant survival rate and marginal bone remodeling expected 5 years after loading using dental implants placed in daily practice. Materials and Methods This research was designed as an open-cohort, prospective, case-series evaluation. Any partially or completely edentulous patient, scheduled to receive at least one bone level implant, was considered eligible for this study. Primary outcome measurements were: implant and prosthetic cumulative survival rate and any complications experienced up to the 5-year follow-up. Secondary outcome measures were: thickness of gingival biotype, implant insertion torque, implant stability quotient, and marginal bone loss (MBL). Results Ninety consecutive patients (34 males and 56 females, aged between 24 and 81 years old [mean: 53.2 ± 15.4]) with 243 inserted implants were followed for at least 5 years after loading (mean: 65.4 ± 3.1 months; range from 60 to 72). At the 1-year follow-up, no drop-outs were recorded, but 17 patients (18.9%) with 18 restorations (12.6%) delivered on 34 implants (14%) were lost at the 5-year examination. At the 5-year follow-up examination, six implants lost osseointegration (97.5%). In the same period, four prostheses failed (97.2%). Five complications were reported in five different patients (prosthetic success rate was 96.5%, at patient level). Five years after loading, the mean MBL was 0.41 ± 0.30 mm. The difference from the 1-year data was 0.04 ± 0.19 mm. A statistically significant higher MBL was found for smokers, and patients with thin gingival biotype. The mean implant insertion torque was 42.9 ± 4.8 Ncm (range from 15 to 45 Ncm). Two-hundred and three implants (83.5%) were inserted with an insertion torque ≥35 and ≤45 Ncm. Conclusions High implant survival and success rate could be expected with stable marginal bone remodeling up to 5 years after loading. Smoking and thin tissue biotype were the most important variabilities associated with higher MBL. Further research studies are needed to confirm these results.


2019 ◽  
Vol 45 (6) ◽  
pp. 503-508 ◽  
Author(s):  
Meng Ma ◽  
Mengxing Qi ◽  
Dongsheng Zhang ◽  
Hongchen Liu

The purpose of this study is to analyze 1- and 3-year clinical performances of narrow diameter implants (NDIs) versus regular diameter implants (RDIs). A search of electronic databases and a manual search was performed for the time period January 2000 to April 2018. A meta-regression was used to evaluate the effects of the “fixed effects” model on the implant survival rates, prosthesis success rates and marginal bone loss (MBL) with follow-up time of 1 year and 3 years. Of the 11 studies included, the overall combined 1-year implant survival rates were 98.14% for NDIs and 98.20% for RDIs. The overall combined 3-year implant survival rates were 98.71% for NDIs and 98.84% for RDIs. The corresponding values for 1-year prosthesis success rates were 96.94% for NDIs and 99.25% for RDIs. The corresponding values for 3-year prosthesis success rates were 89.25% for NDIs and 96.55% for RDIs. The meta-regression showed no significant differences between NDIs and RDIs regarding implant survival rates, prosthesis success rates, and MBL in 1-year and 3-year follow-up (P > .05). The results of this meta-analysis concluded that the implant diameter did not affect its survival rates, prosthesis success rates, and MBL in 1 and 3 years. The use of NDIs instead of bone augmentation procedures with RDIs did not affect its survival rates, prosthesis success rates, and MBL in the short-term and middle-term. However, more high-quality randomized controlled trials and long follow-up studies are needed on this topic.


2019 ◽  
Author(s):  
Samy Aboelyazied Elian

Abstract Background The primary stability in immediate implant placement was considered one of the prerequisites for the achievement of good osseointgration. The insertion torque varies between cases depending on many factors and may goes down to Zero that may affect the prognosis of the implant especially in the soft maxillary bone. The aim of the study was to assess clinically the success&/or failure of immediate flapless implant placement in the maxilla with Zero insertion torque measurement with a follow up time ranging 2-4 years. Results: out of 780 analyzed, fourteen implants were placed in fresh extraction sockets for single rooted teeth in the maxilla and did not get primary stability (zero insertion torque). Their survival rate was 85.7%. Conclusions: The loss of torque during immediate implant placement to Zero may jeopardize the survival of the implants, but it may not be statistically significant with their failure and loss. The lack of certain conditions that are absent during their surgical installation and healing have the major effects on success. The implant primary stability is not an absolute prerequisite to osseointegration; however, it may affect the implant survival rate. Key words: 0 torque implant insertion, implant primary stability, loose implant, immediate implant survival, immediate implant placement.


2019 ◽  
Vol 2019 ◽  
pp. 1-14 ◽  
Author(s):  
Fernanda Faot ◽  
Amália Machado Bielemann ◽  
Alessandra Julie Schuster ◽  
Raissa Micaella Marcello-Machado ◽  
Altair Antoninha Del Bel Cury ◽  
...  

Aim. To evaluate the influence of primary insertion torque (IT) values of narrow dental implants on the peri-implant health, implant stability, immunoinflammatory responses, bone loss, and success and survival rates. Methods. Thirty-one edentulous patients received two narrow implants (2.9x10mm, Facility NeoPoros) to retain mandibular overdentures. The implants were categorized in four groups according to their IT: (G1) IT > 10 Ncm; (G2) IT ≥ 10Ncm and ≤ 30 Ncm; (G3) IT >30Ncm and < 45Ncm; (G4) IT ≥ 45Ncm, and all implants were loaded after 3 months of healing. The following clinical outcomes were evaluated 1, 3, 6, and 12 months after implant insertion: (i) peri-implant tissue health (PH), gingival index (GI), plaque index (PI), calculus presence (CP), probing depth (PD), and bleeding on probing (BOP); (ii) implant stability quotient (ISQ) by resonance frequency analysis; and (iii) IL-1β and TNF-α concentration in the peri-implant crevicular fluid. The marginal bone level (MBL) and changes (MBC) were evaluated. The Chi2 test, Kruskal-Wallis test, mixed-effects regression analysis, and the Kendall rank correlation coefficient were used for statistical analysis (α = 5%). Results. G1 presented the highest PD at all evaluated periods. G2 presented higher PI at month 6 and 12. G4 showed increased GI at month 3 and 12 and more CP at month 1 (p=.003). G2 and G4 had higher ISQ values over the study period, while those from G1 and G3 presented lower ISQ values. The IL-1β concentration increased until month 12 and was independent of IT and bone type; G4 had a higher IL-1β concentration in month 3 than the other groups (p=.015). The TNF-α release was negatively correlated with IT, and TNF-α release was highest in G1 at month 12. The MBL immediately after surgery and the MBC at month 12 were similar between the groups, and G4 presented a positive MBC at month 12. The survival and success rates were 75% for G1, 81.3% for G2, 64.3% for G3, and 95% for G4. Conclusion. The IT did not influence the clinical outcomes and the peri-implant immunoinflammatory responses and was weakly correlated with the narrow dental implants primary stability. The observed success rates suggest that the ideal IT for atrophic fully edentulous patients may deviate from the standardized IT of 32 Ncm.


2021 ◽  
Author(s):  
Rafael Coutinho Mello-Machado ◽  
Suelen Cristina Sartoretto ◽  
Jose Mauro Granjeiro ◽  
José Albuquerque Calasans-Maia ◽  
Marcelo Jose Guedes Pinheiro Uzeda ◽  
...  

Abstract This study aimed to investigate in vivo the hypothesis that the osseodensification technique, through a wider osteotomy, produce healing chambers at the implant-bone interface with no impact on primary stability osseointegration in low-density bone. Twenty implants (3.5 x 10 mm) presenting nanohydroxyapatite (nHA) surface were inserted in the ilium of ten sheep, after preparation of a 2.7-mm wide implant bed with conventional subtractive drilling (SCD) or a 3.8-mm wide implant bed with an osseodensification bur system (OBS) (n = 5/group/period). The final insertion torque (IT) and implant stability quotient (ISQ) evaluated the primary implant stability. After 14 and 28 days, the bone samples containing the implants were processed for histological and histomorphometric evaluation of bone implant contact (BIC) and bone area fraction occupancy (BAFO). No significant differences occurred between the implant bed preparations regarding IT and ISQ (P > 0.05). Histological analysis showed bone remodeling, and bone growth in all samples with no inflammatory infiltrate. BIC values were higher for SCD after 14 and 28 days (p < 0.05), however BAFO values were similar on both groups (p > 0.05). It was possible to conclude that the osseodensification technique allowed a wider implant bed preparation with no prejudice on primary stability and bone remodeling.


2018 ◽  
Vol 44 (2) ◽  
pp. 115-121 ◽  
Author(s):  
John C. Minichetti ◽  
Joseph C. D'Amore ◽  
Anna Y-J Hong

Today, clinicians have a variety of treatment modalities available to address the increasing number of implant procedures performed each year. Single-stage implant surgery is now commonly used in implant dentistry. With patients' demands for immediate restoration, the utilization of 1-piece implants is gaining acceptance. This article reports the results of tapered 1-piece implants (Zimmer Biomet) placed in a single practice over a 10-year period. A total of 33 1-piece dental implants were placed in 24 patients and provisionally restored out of occlusion at the time of surgery. All 33 implants were definitively restored with ceramometal crowns after 3 months of provisionalization. Implant survival and success rates were 100% after 2.6–10 years of follow-up. Only 1 minor complication of crestal bone remodeling occurred among the 33 implants placed. Adequately stabilized tapered 1-piece implants can be successfully restored out of occlusion at the time of implant placement and definitively loaded in occlusion 3 months without adversely affecting function or esthetics. Additional long-term controlled studies are recommended to further understand these findings.


2015 ◽  
Vol 41 (3) ◽  
pp. e60-e65 ◽  
Author(s):  
Carlo Maiorana ◽  
Davide Farronato ◽  
Stefano Pieroni ◽  
Marco Cicciu ◽  
Dario Andreoni ◽  
...  

The purpose of this study was to evaluate the survival rate and incidence of prosthetic complications in 377 implants with a double octagon connection. Furthermore, the correlations among implant dimensions (diameter and length), bone quality, and insertion torque were investigated. A 4-year multicenter prospective clinical study was designed to evaluate the survival rate of 377 dental implants inserted in 189 patients between January 2004 and April 2010. After an average follow-up of 46 months, the implant survival rate was 99.7%, and the incidence of complication was 0.53%. Moreover, insertion torque was statistically related in a significant way to implant diameter. The connection system seemed to reduce the risk that the prosthetic component screw would loosen. Within the limits of this study, it was observed that a wider diameter corresponded to a higher implant primary stability. Implant length did not seem to be critical in obtaining higher primary stability.


Materials ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 2762
Author(s):  
Ki-Won Jeong ◽  
Hyung-In Yoon ◽  
Jae-Hyun Lee ◽  
In-Sung Luke Yeo ◽  
Dae-Joon Kim ◽  
...  

Fifteen participants (9 male, 6 female) received a total of 15 monolithic single restorations made from fully sintered (Y, Nb)-TZP (tetragonal zirconia polycrystal) block. The restorations were clinically evaluated for survival, success rate, and periodontal probing depths 6 months after the insertion of the restorations. Esthetic, functional, and biological evaluations were also performed over a 6-month follow-up period. The survival and success rates of the single-unit restorations were 100%. The periodontal probing depth values ranged from 1 to 3 mm. No complications with regard to functional and biological properties were observed after 6 months. The postoperative sensitivity was only a transient phenomenon. The fully sintered (Y, Nb)-TZP single-unit restoration showed highly acceptable quality with successful clinical performance over 6 months.


2020 ◽  
Vol 2020 ◽  
pp. 1-8
Author(s):  
Lorenzo Andreatta ◽  
Malin Bjursten Brailsford ◽  
Jakob Zwaan

Purpose. To retrospectively investigate the one-year clinical outcome following a standardized treatment protocol for immediate loading. The protocol mandates predefined requirements for implant stability. If fulfilled, immediate loading of the implants is performed with a simplified prosthetic protocol which includes one-time impression at the time of surgery and definitive restoration within eight weeks. Methods. Twenty-five patients were treated with 48 Neoss ProActive Tapered implants. Minimum primary stability was established before subjecting the implants to immediate nonfunctional load. Definitive prostheses were delivered six to eight weeks from implant placement. Insertion torque (IT), resonance frequency analysis (RFA), intraoral radiographs, and impressions of implant positions were registered at implant placement. During clinical follow-up, RFA was measured at two, four, and six to eight weeks and six months from implant placement to monitor continued implant stability. Marginal bone level measurements were performed at implant placement, six-month, and one-year follow-up visits. Results. IT was over 40 N·cm for 46 implants. Two implants with IT <30 N·cm were both splinted to another implant with IT >50 N·cm, tightening the retention screw with low forces. No implants were lost during the observation period. Mean RFA measurements remained stable without any decrease during the initial six-month healing phase. Mean marginal bone remodeling was −0.47 ± 0.38 mm from implant placement to 1 year. No significant difference was found for marginal bone remodeling between implants placed in the healed bone or fresh extraction sockets. Conclusion. Within the limits of this study, it is concluded that using a simplified immediate loading protocol can be predictably applied to reduce the overall treatment time and the number of clinical sessions.


2019 ◽  
Vol 8 (4) ◽  
pp. 427 ◽  
Author(s):  
Xing Yin ◽  
Jingtao Li ◽  
Waldemar Hoffmann ◽  
Angelines Gasser ◽  
John Brunski ◽  
...  

Of all geometric shapes, a tri-oval one may be the strongest because of its capacity to bear large loads with neither rotation nor deformation. Here, we modified the external shape of a dental implant from circular to tri-oval, aiming to create a combination of high strain and low strain peri-implant environment that would ensure both primary implant stability and rapid osseointegration, respectively. Using in vivo mouse models, we tested the effects of this geometric alteration on implant survival and osseointegration over time. The maxima regions of tri-oval implants provided superior primary stability without increasing insertion torque. The minima regions of tri-oval implants presented low compressive strain and significantly less osteocyte apoptosis, which led to minimal bone resorption compared to the round implants. The rate of new bone accrual was also faster around the tri-oval implants. We further subjected both round and tri-oval implants to occlusal loading immediately after placement. In contrast to the round implants that exhibited a significant dip in stability that eventually led to their failure, the tri-oval implants maintained their stability throughout the osseointegration period. Collectively, these multiscale biomechanical analyses demonstrated the superior in vivo performance of the tri-oval implant design.