Low-Pass Filter Property of an Input-Dimensional Output Feedback Passification Controller for Rotary Inverted Pendulum

Author(s):  
Young Ik SON ◽  
Nam Hoon JO ◽  
Hyungbo SHIM ◽  
Goo-Jong JEONG
2018 ◽  
Vol 2018 ◽  
pp. 1-9
Author(s):  
Jeang-Lin Chang ◽  
Tsui-Chou Wu

A low-order dynamics compensator-based output feedback stabilization method for a class of uncertain linear MIMO systems with mismatched disturbances is presented. Since all the system states are not measurable, the proposed controller inherently has low-pass filter property in which it can successfully replace the derivative terms of the system output and hence effectively estimate the input disturbance. The control scheme proposed here can simultaneously consider the input saturation problem and obtain the desired performance. Although the system has unknown uncertainties and disturbances, the uniformly ultimate boundedness of system states in the closed-loop system is analytically shown using the Lyapunov method. Finally, two numerical examples are presented to demonstrate the applicability of the proposed scheme.


2017 ◽  
Vol E100.C (10) ◽  
pp. 858-865 ◽  
Author(s):  
Yohei MORISHITA ◽  
Koichi MIZUNO ◽  
Junji SATO ◽  
Koji TAKINAMI ◽  
Kazuaki TAKAHASHI

2016 ◽  
Vol 15 (12) ◽  
pp. 2579-2586
Author(s):  
Adina Racasan ◽  
Calin Munteanu ◽  
Vasile Topa ◽  
Claudia Pacurar ◽  
Claudia Hebedean

Author(s):  
Nanan Chomnak ◽  
Siradanai Srisamranrungrueang ◽  
Natapong Wongprommoon
Keyword(s):  

Sensors ◽  
2021 ◽  
Vol 21 (13) ◽  
pp. 4305
Author(s):  
Takamasa Terada ◽  
Masahiro Toyoura ◽  
Takahide Sato ◽  
Xiaoyang Mao

In this work, we propose a fabric electrode with a special structure that can play the role of a noise reduction filter. Fabric electrodes made of the conductive fabric have been used for long-term ECG measurements because of their flexibility and non-invasiveness; however, due to the large impedance between the skin and the fabric electrodes, noise is easily introduced into the ECG signal. In contrast to conventional work, in which chip-type passive elements are glued to the electrode to reduce noise, the proposed electrode can obtain a noise-reduced ECG by changing the structure of fabric. Specifically, the proposed electrode was folded multiple times to form a capacitor with a capacitance of about 3 nF. It is combined with the skin-electrode impedance to form a low-pass filter. In the experiment, we made a prototype of the electrodes and measured ECG at rest and during EMG-induced exercise. As a result, the SNR values at rest and during exercise were improved about 12.02 and 10.29 , respectively, compared with the fabric electrode without special structure. In conclusion, we have shown that changing the fabric electrode structure effectively removes noise in ECG measurement.


Sign in / Sign up

Export Citation Format

Share Document