scholarly journals Root Canal Penetration of a Sodium Hypochlorite Mixture Using Sonic or Ultrasonic Activation

2014 ◽  
Vol 25 (6) ◽  
pp. 489-493 ◽  
Author(s):  
Marta Sáinz-Pardo ◽  
Roberto Estevez ◽  
Óliver Valencia de Pablo ◽  
Giampiero Rossi-Fedele ◽  
Rafael Cisneros

The purpose of this ex vivo study was to determine, in "open" and "closed" systems, whether the design has an influence on the penetration length of sodium hypochlorite mixed with a radiopaque contrast medium, measured in millimeters, when delivered using positive pressure (PP) and using sonic (SI) or passive ultrasonic (PUI) activation. Sixty single-rooted teeth were divided into two groups: open and closed systems (n=30). Root canal shaping was performed to a working length of 17 mm. The samples were divided into three sub-groups (n=10) according to irrigant delivery and activation: PP, and SI or PUI activation. By using radiographs, penetration length was measured, and vapor lock was assessed. For the closed group, the penetration distance means were: PP 15.715 (±0.898) mm, SI 16.299 (±0.738) mm and PUI 16.813 (±0.465) mm, with vapor lock occurring in 53.3% of the specimens. In the open group, penetration to 17 mm occurred in 97.6% of the samples, and no vapor lock occurred. Irrigant penetration and distribution evaluation using open and closed systems provide significantly different results. For closed systems, PUI is the most effective in delivering the irrigant to working length, followed by SI.

2011 ◽  
Vol 44 (5) ◽  
pp. 402-406 ◽  
Author(s):  
A. P. C. A. Beltrame ◽  
T. C. Triches ◽  
N. Sartori ◽  
M. Bolan

2020 ◽  
Vol 14 (4) ◽  
pp. 235-238
Author(s):  
Yogesh Damade ◽  
Ramchandra Kabir ◽  
Sunanda Gaddalay ◽  
Sharvaree Deshpande ◽  
Sonali Gite ◽  
...  

Background. This study aimed to investigate the endodontic debridement efficacy of different sodium hypochlorite (NaOCl) irrigation regimens with and without ultrasonic agitation, followed by ethylenediaminetetraacetic acid (EDTA) via scanning electron microscopy (SEM) after using a rotary instrumentation system. Methods. Mandibular premolars (n=50) were randomly divided into five experimental groups (n=10) for root canal instrumentation with ProTaper Universal rotary system up to F3. The root canal system was treated with intracanal-heated NaOCl (100°C) or preheated NaOCl (55°C), followed by ultrasonic agitation and EDTA treatment. Samples irrigated with conventional needle irrigation (CNI) using normal saline solution were used as controls. Debridement efficacy was analyzed by SEM. A five-point scale was used to estimate the presence/absence of debris for each canal segment (coronal, middle, and apical). The results were analyzed using one-way ANOVA and post hoc Tukey tests (P<0.05). Results. The experimental groups exhibited less debris compared to CNI with saline (P<0.05). The amount of debris decreased significantly for the group with NaOCl intracanal heating compared to extraoral heating. Ultrasonic agitation further enhanced the root canal debridement efficacy of NaOCl. Conclusion. In summary, intracanal heating of NaOCl with and without ultrasonic agitation followed by EDTA appears to be a promising method to flush debris from the root canal system.


2020 ◽  
Vol 25 (1) ◽  
pp. 231-236
Author(s):  
Adriane Antoniw Klemz ◽  
Alessandra Timponi Goes Cruz ◽  
Lucila Piasecki ◽  
Everdan Carneiro ◽  
Vânia Portela Ditzel Westphalen ◽  
...  

2020 ◽  
Vol 10 (1) ◽  
Author(s):  
T. G. Wolf ◽  
F. Fischer ◽  
R. K. W. Schulze

Abstract To investigate potential correlations between objective CBCT image parameters and accuracy in endodontic working length determination ex vivo. Contrast-to-noise ratio (CNR) and spatial resolution (SR) as fundamental objective image parameters were examined using specific phantoms in seven different CBCT machines. Seven experienced observers were instructed and calibrated. The order of the CBCTs was randomized for each observer and observation. To assess intra-operator reproducibility, the procedure was repeated within six weeks with a randomized order of CBCT images. Multivariate analysis (MANOVA) did not reveal any influence of the combined image quality factors CNR and SR on measurement accuracy. Inter-operator reproducibility as assessed between the two observations was poor, with a mean intra-class correlation (ICC) of 0.48 (95%-CI  0.38, 0.59) for observation No. 1. and 0.40 (95%-CI 0.30, 0.51) for observation No. 2. Intra-operator reproducibility pooled over all observers between both observations was only moderate, with a mean ICC of 0.58 (95%-CI 0.52 to 0.64). Within the limitations of the study, objective image quality measures and exposure parameters seem not to have a significant influence on accuracy in determining endodontic root canal lengths in CBCT scans. The main factor of variance is the observer.


2016 ◽  
Vol 42 (4) ◽  
pp. 610-614 ◽  
Author(s):  
Thomas Gerhard Wolf ◽  
Frank Paqué ◽  
Maximilian Zeller ◽  
Brita Willershausen ◽  
Benjamín Briseño-Marroquín

2014 ◽  
Vol 10 (1) ◽  
Author(s):  
Benjamín Briseño Marroquín ◽  
Claudia Cortazar Fernández ◽  
Irene Schmidtmann ◽  
Brita Willershausen ◽  
Fernando Goldberg
Keyword(s):  
Ex Vivo ◽  

Sign in / Sign up

Export Citation Format

Share Document