scholarly journals Energy-Dispersive X-Ray Spectrometry Analysis and Radiopacity of Five Different Root Canal Sealers

2021 ◽  
Vol 32 (5) ◽  
pp. 1-11
Author(s):  
Gözde Kandemir Demirci ◽  
Mehmet Emin Kaval ◽  
Seniha Miçooğulları Kurt ◽  
Burcu Serefoglu ◽  
Pelin Güneri ◽  
...  

Abstract Root canal sealers should have optimum adhesion to the root dentin, low cytotoxicity, sufficient radiopacity and high dimensional stability, which depend mainly on their chemical composition. The aims of this study were to evaluate the chemical composition of Syntex (Cerkamed, Stalowa Wola, Poland), Adseal (Meta Biomed, Cheongju-si, Korea), Sealapex (SybronEndo, Scafati, Italy), MTA Fillapex (Angelus, Londrina, Brazil) and GuttaFlow Bioseal (Coltene/Whaledent, Altstätten, Switzerland) and to determine their radiopacity comparatively. Stainless steel molds with an inner diameter of 5 mm and a depth of 2 mm were constructed. Tested root-canal sealers were mixed and poured into the molds. Following setting, digital periapical radiographs of the specimens (n=12) were taken under standard exposure conditions and the mean gray-values of specimens were measured using a computer graphics program. Then the specimens were examined by scanning electron microscopy, and Energy-dispersive X-ray analysis was performed. The data were analyzed using One-way ANOVA followed by Holm-Sidak multi-comparison test (p = 0.05). Sealapex showed higher calcium peak than MTA Fillapex, GuttaFlow Bioseal, Adseal and Syntex sealers. MTA Fillapex contained a highest amount of tungstate. Sealapex presented the highest radiopacity value among the tested materials (p < 0.05), whereas MTA Fillapex was the least radiopaque material (p < 0.05). Each root canal sealer contains different compositions of radiopacifiers including bismuth oxide, calcium tungstate and zirconium oxide. The tested root canal sealers had radiopacity values above the ISO-specified limit. Sealapex was the most radiopaque root canal sealer followed by GuttaFlow Bioseal, Syntex, Adseal and MTA Fillapex.

2016 ◽  
Vol 2016 ◽  
pp. 1-8 ◽  
Author(s):  
Przemysław Reszka ◽  
Alicja Nowicka ◽  
Mariusz Lipski ◽  
Włodzimierz Dura ◽  
Agnieszka Droździk ◽  
...  

Objective.The present study assessed the chemical elements in two novel calcium silicate-containing root canal sealers, BioRoot RCS and Well-Root ST, compared to a calcium silicate-containing root canal sealer that has been on the market for several years, MTA Fillapex, and epoxy resin-based sealer AHPlus.Material and Methods.The sealers were mixed and manipulated according to the manufacturers’ instructions. Twelve cylindrical molds (inner diameter 4 mm; height 3 mm) were placed on a glass petri dish and packed with the materials. The dish was transferred to an incubator. After 72 h the molds were examined by scanning electron microscopy and energy dispersive X-ray microanalysis.Results.BioRoot RCS and Well-Root ST had high peaks of calcium, zirconium, oxygen, carbon, silicon, and chlorine. Well-Root ST also had sodium, magnesium, aluminum, and titanium peaks. MTA Fillapex and AHPlus had carbon, oxygen, calcium, titanium, and bismuth peaks. A silicon peak was also observed for MTA Fillapex, and zirconium and tungsten peaks for AHPlus.Conclusion.BioRoot RSC had the highest degree of purity. The clinical implication of metals contained in the other sealers needs to be investigated.


1979 ◽  
Vol 48 (6) ◽  
pp. 558-560 ◽  
Author(s):  
Abdel Rahim Mohammad ◽  
Osama Younis ◽  
Milton Siskin
Keyword(s):  
X Ray ◽  

2018 ◽  
Vol 82 (2) ◽  
pp. 144-148 ◽  
Author(s):  
H. Simsek ◽  
M. Coruh ◽  
F. Cakici ◽  
F. Fundaoglu Kucukekenci ◽  
T. Gurbuz ◽  
...  

2007 ◽  
Vol 330-332 ◽  
pp. 1357-1360
Author(s):  
Li Zhao Teng ◽  
Hong Song Fan ◽  
Xing Dong Zhang

The purpose of this study was to evaluate biocompatibility of a new injectable root canal sealer. The cytotoxicity of zinc oxide-eugenol cements, CCQ and the new injectable root canal sealer were assessed by the MTT assays. These materials were filled into the root canals of the dog. One month later, the dog was sacrificed and the X-ray photos were taken. The histological response was observed through the microscope. The results show the new injectable root canal sealer showed better biocompatibility than the other two materials.


2016 ◽  
Vol 42 (12) ◽  
pp. 1834-1839 ◽  
Author(s):  
Zhejun Wang ◽  
Hazuki Maezono ◽  
Ya Shen ◽  
Markus Haapasalo

2016 ◽  
Vol 48 (10) ◽  
pp. 985-994 ◽  
Author(s):  
Keila de Almeida Franceschini ◽  
Yara Teresinha Corrêa Silva-Sousa ◽  
Fabiane Carneiro Lopes ◽  
Rodrigo Dantas Pereira ◽  
Regina Guenka Palma-Dibb ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document