scholarly journals NSK reciprocating handpiece: in vitro comparative analysis of dentinal removal during root canal preparation by different operators

2006 ◽  
Vol 17 (1) ◽  
pp. 10-14 ◽  
Author(s):  
Márcia Helena Wagner ◽  
Fernando Branco Barletta ◽  
Magda de Souza Reis ◽  
Luciano Loureiro Mello ◽  
Ronise Ferreira ◽  
...  

The purpose of this study was to assess dentin removal during root canal preparation by different operators using a NSK reciprocating handpiece. Eighty-four human single-rooted mandibular premolars were hand instrumented using Triple-Flex stainless-steel files (Kerr) up to #30, weighed in analytical balance and randomly assigned to 4 groups (n=21). All specimens were mechanically prepared at the working length with #35 to #45 Triple-Flex files (Kerr) coupled to a NSK (TEP-E10R, Nakanishi Inc.) reciprocating handpiece powered by an electric motor (Endo Plus; VK Driller). Groups 1 to 4 were prepared by a professor of Endodontics, an endodontist, a third-year dental student and a general dentist, respectively. Teeth were reweighed after root canal preparation. The difference between weights was calculated and the means of dentin removal in each group were analyzed statistically by ANOVA and Tukey's test at 5 % significance level. The greatest amount of dentin removal was found in group 4, followed by groups 2, 3 and 1. Group 4 differed statistically from the other groups regarding dentin removal means [p<0.001 (group 1); p=0.005 (group 2); and p=0.001 (group3)]. No statistically significant difference was found between groups 1 and 2 (p=0.608), 1 and 3 (p=0.914) and 2 and 3 (p=0.938). In conclusion, although the group prepared by a general dentist differed statistically from the other groups in terms of amount of dentin removal, this difference was clinically irrelevant. The NSK reciprocating handpiece powered by an electric engine was proved an effective auxiliary tool in root canal preparation, regardless of the operator's skills.

2007 ◽  
Vol 18 (1) ◽  
pp. 16-19 ◽  
Author(s):  
Lilia E. Leonardi ◽  
Diana M. Atlas ◽  
Guillermo Raiden

The aim of the present study was to assess the presence of apically extruded debris and evaluate the influence of canal curvature on the amount of debris produced by manual and mechanical techniques. Forty single-rooted mature teeth with 15 to 30 degree of root canal curvature were selected. The presence of only one foramen was confirmed using a magnifying lens. A size 15 K-file was placed up to the apical foramen to determine the patency. Working length was determined with the same instrument, 1 mm short of the foramen. According to the employed technique, the groups were labeled as follows: Group 1 - Manual instrumentation with Mor-flex files; Group 2 - Mechanical instrumentation with Cursor and Mor-flex files; Group 3 - Manual instrumentation with Flexi-cut files; Group 4 - Mechanical instrumentation with Cursor and Flexi-cut files. During instrumentation, the root canals were irrigated with 20 mL. Debris extruded through the apical foramen was collected using the Myers and Montgomery technique. The values (in mg) were: Group 1: 0.422 ± 0.683; Group 2: 0.688 ± 0.795; Group 3: 0.409 ± 0.323; Group 4: 0.810 ± 0.708. Data were analyzed statistically by ANOVA at 5% significance level. There was no statistically significant difference among the groups (p<0.05). No statistically significant differences were found between slight and moderate curvatures in terms of the amount of extruded debris (p>0.05).


2021 ◽  
Vol 15 (1) ◽  
pp. 30-34
Author(s):  
Neslihan Yılmaz Çırakoglu ◽  
Yağız Özbay

Background. This research aimed to investigate and compare the amount of apically extruded debris after root canal preparation using ProTaper Next, ProTaper Gold, and TruNatomy systems. Methods. Forty-five extracted mandibular premolar teeth with single canals with similar lengths were used. The root canals were prepared using ProTaper Next (Dentsply Maillefer, Ballaigues, Switzerland), ProTaper Gold (Dentsply Maillefer, Ballaigues, Switzerland), or TruNatomy (Dentsply Maillefer, Ballaigues, Switzerland) files. Apically extruded debris during preparation was gathered into preweighed Eppendorf tubes. Then the Eppendorf tubes were incubated at 70°C for five days. The Eppendorf tubes were weighed again to determine their final weight plus the extruded debris. Results. The TRN system resulted in significantly less debris extrusion than the PTN system (P<0.05). There was no significant difference between the PTN and PTG groups and between the PTG and TRN groups (P>0.05). Conclusion. All the instrumentation systems caused apical extrusion of debris. However, the TRN system resulted in significantly less debris extrusion than the other systems.


2007 ◽  
Vol 18 (1) ◽  
pp. 20-23 ◽  
Author(s):  
João Vicente Baroni Barbizam ◽  
Matheus Souza ◽  
Doglas Cecchin ◽  
Jakob Dabbel

The purpose of this in vitro study was to evaluate the ability of a silicon-based root canal sealer, compared to zinc oxide and eugenol and an epoxy resin-based sealers, for filling of simulated lateral canals. Thirty extracted single-rooted human teeth were selected, conventional access was made and the working length was established 1 mm from the apical foramen. Three simulated lateral canals, one in each root third (coronal, middle and apical) were prepared in both the mesial and distal surfaces of each tooth using a size 15 reamer adapted to a low-speed handpiece. Each root canal was instrumented using ProTaper rotary files up to file F3 at the working length, and then irrigated with 2.5% NaOCl followed by EDTA. The teeth were assigned to 3 groups (n=10), according to the root canal sealer: Roeko Seal (Group 1), Sealer 26 (group 2) and Grossman's sealer (Group 3). Gutta-percha cold lateral condensation technique was performed in all groups. Postoperative radiographs were taken and the images were projected for evaluation of the quality of lateral canal filling. Data were submitted to statistical analysis by Kruskal Wallis test at 5% significance level. The results showed that Grossman's sealer filled a larger number of lateral canals than Roeko Seal (p<0.05) and Sealer 26 (p<0.01). It may be concluded that Roeko Seal silicone-based root canal sealer was not as effective as the Grossman's sealer for filling of simulated lateral canals. The lateral canals localized in the apical third of the root were more difficult to be filled.


2005 ◽  
Vol 6 (3) ◽  
pp. 53-61 ◽  
Author(s):  
Hanan Balto ◽  
Saad Al-Nazhan ◽  
Khulood Al-Mansour ◽  
Moneera Al-Otaibi ◽  
Yunus Siddiqu

Abstract The aim of this study was to evaluate the integrity of the coronal seal of Temp-Bond and compare it to Cavit and IRM after post space preparation using S. faecalis as a microbial tracer. In addition, the affect of two methods of gutta percha removal on the apical seal of root canal fillings was also evaluated. Forty extracted human single rooted teeth were prepared chemomechanically and obturated with gutta percha and AH26 sealer cement using the lateral cold condensation technique to a standardized working length of 15 mm. About 10 mm of the coronal gutta-percha was removed with either Peeso-reamer or a hot plugger. The roots were divided into three experimental groups of 10 roots and a control group. Each experimental group was subdivided equally into two groups of 15 each according to the method of post space preparation. Cavit, IRM, and Temp-Bond were used to seal the access opening. Each root was fixed in a cuvette containing Tryptic Soya Broth which, covered 2 mm of the root apex. Bacterial suspension was introduced through pipette. Fresh bacterial suspension was added every week, and the system was monitored daily for the growth of microorganisms for a period of one month. The results showed there was no significant difference in terms of coronal leakage between the three coronal materials used (P=0.478), but the methods of gutta-percha removal did have an impact on the apical leakage (P=0.047). The mean value showed the Peeso-reamer provided less leakage compared to using a hot plugger during the 30-day experimental time period. It was concluded the temporary type of coronal seal of endodontically treated teeth will not prevent coronal leakage if left for a long period of time. In addition, permanent cementation of the post with the coronal restoration should be carried out as soon as possible to prevent recontamination of the root canal. Citation Balto H, Al-Nazhan S, Al-Mansour K, Al-Otaibi M, Siddiqu Y. Microbial Leakage of Cavit, IRM, and Temp Bond in Post-prepared Root Canals Using Two Methods of Gutta-percha Removal: An In Vitro Study. J Contemp Dent Pract 2005 August;(6)3:053-061.


2015 ◽  
Vol 2015 ◽  
pp. 1-4 ◽  
Author(s):  
Mehmet Bani ◽  
Elif Sungurtekin-Ekçi ◽  
Mesut Enes Odabaş

The aim of this study was to evaluate the apical microleakage of Biodentine and MTA orthograde apical plugs and to compare the effect of thickness of these biomaterials on their sealing ability. A total of eighty maxillary anterior teeth were used. The apices were removed by cutting with a diamond disc (Jota, Germany) 2 mm from the apical root end in an attempt to standardize the working length of all specimens to 15 ± 1 mm. Both materials were placed in 1–4 mm thickness as apical plugs root canal. Root canal leakage was evaluated by the fluid filtration technique. One-way ANOVA was used in order to determine normality of dispersal distribution of parameters; thereafter, results were analyzed by Kolmogorov-Smirnov test. Overall, between microleakage values of MTA and Biodentine regardless of apical plug thickness, no difference was observed. In terms of plug thickness, a statistically significant difference was observed between the subgroups of MTA and Biodentine (p<0.05). The apical sealing ability of Biodentine was comparable to MTA at any apical plug thickness.


2016 ◽  
Vol 1 (2) ◽  
pp. 66-69
Author(s):  
Madhusudhana Koppolu ◽  
Chinni Suneelkumar ◽  
Anumula Lavanya ◽  
Ram Basam

ABSTRACT Aim To evaluate the amount of apically extruded debris after the preparation of root canals in extracted human single-rooted teeth using ProTaper Next and Mani Silk rotary systems. Materials and methods A total of 40 freshly extracted human single-rooted teeth with mature apices and straight root canal were selected and similar length were instrumented with ProTaper Next and Mani Silk rotary systems. Debris and irrigant extruded during instrumentation were collected into preweighed Eppendorf tubes. The Eppendorf tubes were then stored in an incubator at 68°C for 5 days. The weight of the extruded debris was determined by subtracting the initial weight from the final weight. Statistical analysis Data analysis was carried out using the Statistical Package for the Social Sciences (SPSS) version 20. Postweights were compared with an independent t test for 2 groups. Results Both instruments were associated with apical debris extrusion. There was no significant difference between the ProTaper Next and Mani Silk instruments in terms of mean weight of apically extruded debris. Conclusion There was no significant difference among the groups in terms of mean weight of apically extruded debris. How to cite this article Koppolu M, Basam R, Suneelkumar C, Lavanya A. Apical Debris Extrusion during Root Canal Preparation with ProTaper Next and Mani Silk Rotary Systems: An in vitro Study. J Oper Dent Endod 2016;1(2):66-69.


2021 ◽  
Vol 10 (5) ◽  
pp. e9810514765
Author(s):  
Arieth Cristina Sacomani ◽  
Fernanda Tessaro Cintra ◽  
Adriana de Jesus Soares ◽  
Marcos Frozoni

To evaluate the influence of reciprocating single-file instrumentation with different working lengths (WL) on the reduction of planktonic bacteria and bacterial biofilm in Enterococcus faecalis-contaminated oval root canals. Methodology: Fifty-five human single-rooted canines were used. Fifty were inoculated with E. faecalis for 21 days for biofilm formation. To confirm the formation of biofilm adhered to the root canal wall, 5 contaminated samples from positive control group were analyzed by SEM. Samples were assigned into 3 groups (n = 15) according to working length determined, G+1 root canal preparation 1 mm beyond the apical foramen, G0 root canal preparation at the major foramen, and G-1 root canal preparation 1 mm short of the major foramen. Five roots were not inoculated to serve as a negative control. Bacteriological samples were collected prior to preparation, initial collection (S1), and after reciprocating instrumentation (S2) by disaggregating biofilm to quantify the reduction of planktonic bacteria and intracanal biofilm at different WL. Bacterial quantitation was performed using colony-forming units per milliliter (CFU / mL) count. Statistical analysis was performed at the significance level of 0.05. Results: No bacterial growth was observed in the negative control. All positive controls demonstrated bacterial growth; S1 from all teeth were positive for bacteria with no significant difference. The post-hoc analysis showed G+1 promoting a significantly higher disinfection than G-1 (p<0,05) and G-1 similar disinfection to G0 (P=962). Conclusion: Instrumentation as close as possible to major foramen or beyond it improves decontamination in oval root canals with reciprocating instrumentation.


2016 ◽  
Vol 2016 ◽  
pp. 1-7 ◽  
Author(s):  
Maciej Janeczek ◽  
Piotr Kosior ◽  
Dagmara Piesiak-Pańczyszyn ◽  
Krzysztof Dudek ◽  
Aleksander Chrószcz ◽  
...  

Measurements of the root canal during endodontic treatment have a significant influence on the course of the therapeutic process as well as on its final result in both human and veterinary medicine. The apical constriction should be the termination point for the preparation and filling of the root canal. This research was conducted with the use of a Septodont kit consisting of a small chamber filled with the examined solution in which a healthy second incisor was placed. The step back method was applied for the root canal preparation and master apical file of 30 was used. The working length was 22 mm. The examination was conducted with the use of steel as well as nickel titanium hand instruments. Different irrigation solutions and two types of apex locators were used. Measurements of the working length of the root canal showed dependence on the size of the instrument. Examinations carried out in various environments showed that analogical measurements were obtained only for sodium hypochlorite solutions. In other environments the measured sections were shortened. Comparative examinations with the use of steel instruments demonstrated insignificant measurement differences. Compared to these results, the measurements in nickel titanium group were characterized by more considerable deviations.


2020 ◽  
Vol 31 (3) ◽  
pp. 201-220
Author(s):  
Alânia Dalla Valle ◽  
Lara Dotto ◽  
Renata Dornelles Morgental ◽  
Tatiana Pereira-Cenci ◽  
Gabriel Kalil da Rocha Pereira ◽  
...  

Abstract The effect of root canal preparation technique on microcrack initiation is a controversial issue. This systematic review aimed to assess the role of root canal preparation techniques with different kinematics (manual, rotary, reciprocating, adaptive, self-adjusting file) on microcrack initiation. In vitro and in situ studies comparing the influence of at least two different root canal preparation techniques on the initiation of dentin microcracks were searched in PubMed/MEDLINE and SCOPUS up to June 5, 2018 without language and period restriction. Two authors independently reviewed all identified titles and abstracts for eligibility. Tables were generated to summarize the included studies, and the included studies were assessed for bias. Fifty-four (n=54) articles met the eligibility criteria. The results were classified according to the method used for microcrack evaluation, and most studies that used micro-computed tomography showed no formation of new cracks after root canal preparation. In general, the instrumentation techniques induced microcrack formation when the methods were destructive, irrespective of kinematics. In relation to the apex region, when the preparation working length was set as the root canal length subtracted of 1 mm, the risk of microcrack initiation reduces. The majority of the included studies had low risk of bias for all assessed domains. Our results seem to indicate that the various root canal preparation techniques considered in this study will not cause damage to the dental structure when adequately employed and the proper methodology is applied.


Author(s):  
Pegah Sarraf ◽  
Nazanin Kiomarsi ◽  
Farrokh Haj Taheri ◽  
Behrang Moghaddamzade ◽  
Fatemeh Dibaji ◽  
...  

Objectives: This study aimed to compare the transportation of the mesiobuccal canal of maxillary molars following root canal preparation with HyFlex CM (HCM) and Edge Taper Platinum (ETP) rotary systems and stainless steel (SS) hand files using cone-beam computed tomography (CBCT). Materials and Methods: This in-vitro study was performed on 48 maxillary molars in three groups of 16. The teeth were mounted in acrylic blocks, and root canals were prepared using HCM in group 1 (up to #30/0.06), ETP in group 2 (up to F3/0.06), and SS hand files in group 3 (up to #30). CBCT scans were taken before and after root canal preparation. The amount of canal transportation was measured at 0, 3, 6, and 9mm from the apex. Data were analyzed using Kruskal-Wallis and Mann-Whitney tests. Results: The difference in canal transportation at 0 and 6mm from the apex was significant between the HCM and ETP groups (P=0.031 and 0.023) but none of the systems showed any significant difference with hand files at 0- and 6-mm levels (P=0.10, 0.56, 0.22, and 0.50), respectively. At 3mm from the apex, no significant difference was noted among the groups (P=0.30). At the 9-mm level, the amount of canal transportation was not significantly different between HCM and ETP (P=0.83) but they showed significant differences with hand files (P<0.001). Conclusion: ETP and HCM caused less canal transportation at the curvature of the mesiobuccal canal of maxillary molars compared to hand files. ETP showed superior efficacy in root canal preparation compared to HCM.


Sign in / Sign up

Export Citation Format

Share Document