scholarly journals Effect of a bonding resin layer associated with a self-etching adhesive system on the bond strength of indirect restorations

2007 ◽  
Vol 15 (2) ◽  
pp. 94-98 ◽  
Author(s):  
Carolina Guimarães Castro ◽  
Paulo César Freitas Santos Filho ◽  
Adérito Soares da Mota ◽  
Roberto Elias Campos ◽  
Carlos José Soares
2018 ◽  
Vol 2 (3) ◽  
pp. 157-162 ◽  
Author(s):  
Daphne Camara Barcellos ◽  
Priscila Holleben ◽  
Beatriz Maria Fonseca ◽  
Bruna de Cássia Sabino ◽  
Sérgio Eduardo de Paiva Gonçalves

2006 ◽  
Vol 31 (5) ◽  
pp. 604-609 ◽  
Author(s):  
M. Franke ◽  
A. W. Taylor ◽  
A. Lago ◽  
M. C. Fredel

Clinical Relevance Statistical analysis of the results obtained in this study shows that Nd:YAG laser irradiation on the adhesive system has a significant influence on bond strength to dentin. Bond strength is improved by better adhesive penetration when low energy is applied; whereas, high energy densities have a deleterious effect on the procedure.


2012 ◽  
Vol 17 (4) ◽  
pp. 1-7 ◽  
Author(s):  
Roberto Hideo Shimizu ◽  
Karlos Giovani Grando ◽  
Isabela Almeida Shimizu ◽  
Augusto Ricardo Andriguetto ◽  
Ana Cláudia Moreira Melo ◽  
...  

OBJECTIVE: This in vitro study was designed to evaluate the shear bond strength (SBS) of orthodontic metal brackets bonded by direct and indirect techniques. METHODS: Thirty healthy human maxillary premolar teeth were used. The teeth were divided into three groups of 10 teeth each: Group I - indirect bonding with SondhiTM Rapid-Set system (3M/Unitek), Group II - indirect bonding with TransbondTM XT adhesive system (3M/Unitek) and Group III - direct bonding with TransbondTM XT adhesive system (3M/Unitek). After bonding and obtaining the specimens for the study, the specimens were subjected to SBS testing in a universal testing machine (Emic, model DL-500). The Kolmogorov-Smirnov test was applied to ascertain that the data had a normal distribution and the Bartlett test to check whether there was homogeneity of variance. One-factor analysis of variance was performed and, subsequently, Tukey's test for paired means. A 5% significance level was adopted. RESULTS: The results of Group I were 67.6 (N) and 5.9 (MPa); Group II, 68.9 (N) and 6.1 (MPa) and Group III (control), 92.5 (N) and 8.1 (MPa). CONCLUSION: It can therefore be concluded that the means for Group III were significantly higher compared with Groups I and II in both Newton (N) and Megapascal (MPa) values. The means attained by the indirect bonding technique used in Groups I and II, however, exhibited no statistically significant differences.


2018 ◽  
Vol 32 (4) ◽  
pp. 163
Author(s):  
Fábio Herrmann Coelho-de-Souza ◽  
Guilherme Fossá ◽  
Flávia Ávila Pereira ◽  
Celso Afonso Klein-Júnior ◽  
Maria Carolina Guilherme Erhardt ◽  
...  

OBJECTIVE: This study evaluated in vitro the shear bond strength of experimentally fractured human tooth fragments reattached with different adhesive materials and retentive techniques.METHODS: Forty-eight sound mandibular incisors were randomly divided into 6 groups (n=8). Their incisal edges were cut off in 5 groups, representing an enamel-dentin fracture. Intact teeth were used as control (Group 1). The fragment edges were reattached with adhesive system (Scotch Bond Multipurpose – 3M ESPE) (Group 2), adhesive system and composite resin (ICE – SDI) (Group 3), adhesive system and composite resin with circumferential bevel (Group 4), adhesive system and composite resin with internal dentin groove (Group 5), and adhesive system and composite resin with the circumferential bevel and internal dentin groove (Group 6). Shear bond strength was determined in a universal testing machine. Fracture modes were identified by light microscope. Kruskal-Wallis was used to analysis resistance to fracture and fracture patterns.RESULTS: The results showed statistically significant differences (p<0.05) among groups. The intact teeth (Group 1) showed higher fracture resistance than the other groups. Groups 2 and 6 did not differ and were statistically superior to other techniques. Group 4 presented statistically higher than in Group 5, which in turn was more resistant than Group 3.CONCLUSIONS: None of the fragment reattachment techniques was able to achieve the strength of sound teeth. Fragments reattached only with adhesive system or with adhesive system and composite resin with the circumferential bevel and internal dentin groove showed the best performance for resistance to fracture.


2007 ◽  
Vol 31 (1) ◽  
pp. 35-40 ◽  
Author(s):  
Carla Miranda ◽  
Luiz Henrique Maykot Prates ◽  
Ricardo de Souza Vieira ◽  
Maria Cristina Marino Calvo

The aims of this study were to evaluate the shear bond strength (SBS) of four adhesive systems applied to primary dentin and enamel and verify, after SBS testing, the failure mode of the adhesive interface. Sixty extracted sound primary molars were selected and crowns were sectioned in a mesial-distal direction. Specimens were randomly assigned into two groups (adhesion to enamel and adhesion to dentin) and then subdivided into four subgroups according to the adhesive system (n=15): Scotchbond Multi-Purpose (SMP) – Single Bond (SB) – Clearfil SE Bond (and Adper Prompt LPop (APL) – SBS tests were performed and the obtained values were statistically analyzed using ANOVA and Tukey tests (p&lt;0.05). The failure mode analysis was performed with a Scanning Electron Microscope (XL-30, Philips). SBS mean values on enamel were [MPa (SD)]: SMP – 27.89 (7.49); SB – 23.92 (8.8); CSB – 24.36 (6.69); APL – 25.96 (4.08); and on dentin: SMP – 17.29 (4.25); SB – 18.2 (8.74); CSB – 16.13 (7.14); APL – 6.04 (3.35). The predominant failure mode was cohesive (primarily of the bonding agent). On enamel SBS was statistically similar for all four adhesives. On dentin SBS of APL was lower than the other tested adhesives.


2015 ◽  
Vol 16 (7) ◽  
pp. 547-553 ◽  
Author(s):  
Roberta Tarkany Basting ◽  
Cecília Pedroso Turssi ◽  
Flavia Lucisano Botelho do Amaral ◽  
Fabiana Mantovani Gomes França ◽  
Rafaela Crystyan Vaneli ◽  
...  

ABSTRACT Aim The aim of this study was to evaluate the effect of chlorhexidine and ethanol application on the push-out bond strength and bond durability of fiber posts cemented with an etch-and-rinse adhesive system/resin cement to intraradicular dentin. Materials and methods Fifty-four bovine roots were shaped for the cementation of a fiberglass post and received the application of 37% phosphoric acid. They were then randomly divided into three groups, according to the type of dentin treatment (n = 18) performed: no treatment (control group), 100% ethanol, or 2% chlorhexidine. Next, the adhesive system (Adper Scotch Bond Multipurpose Plus, 3M ESPE) was applied to the dentin, according to the manufacturer's instructions. Glass fiber posts were cemented with dual resin cement (Rely X ARC, 3M ESPE). After 48 hours, the specimens were serially sectioned for push-out test analysis, providing two slices from each root third (cervical, medium and apical), one of which was tested immediately and the other stored in distilled water for 180 days. The data were analyzed with three-way analysis of variance (ANOVA) for repeated measures and Tukey's test at a 5% significance level. Results Intraradicular treatment with chlorhexidine yielded the highest bond strength means, followed by ethanol treatment. The control group presented the lowest bond strength means. Water storage exerted no effect on bond strength values. Conclusion Both chlorhexidine and ethanol improved push-out bond strength to intraradicular dentin, with the former providing the best results, regardless of the storage time. Clinical significance The application of 2% chlorhexidine or 100% ethanol may be an important step that can be taken to enhance bond strength of fiber posts to intraradicular dentin, when dual resin cements are used. How to cite this article França FMG, Vaneli RC, de Melo Conti C, Basting RT, do Amaral FLB, Turssi CP. Effect of Chlorhexidine and Ethanol Application on Long-term Pushout Bond Strength of Fiber Posts to Dentin. J Contemp Dent Pract 2015;16(7):547-553.


2020 ◽  
Vol 19 ◽  
pp. e206155
Author(s):  
Yançanã Luizy Gruber ◽  
Thaís Emanuelle Bakaus ◽  
Bruna Fortes Bittencourt ◽  
João Carlos Gomes ◽  
Alessandra Reis ◽  
...  

Aim: The roughness and micromorphology of various surface treatments in aged metal-free crowns and the bond strength of these crowns repaired with composite resin (CR) was evaluated in vitro. Methods: A CR core build-up was confectioned in 60 premolars and prepared for metal-free crowns. Prepared teeth were molded with the addition of silicone, and the laboratory ceromer/fiber-reinforced crowns (SR Adoro/Fibrex Lab) were fabricated. Subsequently, the crowns were cemented and artificially aged in a mechanical fatigue device (1.2 X 106 cycles), then divided into 4 groups (n = 15) according to the surface treatment: 1) phosphoric acid etching (PA); 2) PA + silane application; 3) roughening with a diamond bur + PA; and 4) sandblasting with Al2O3 + PA. After the treatments, the crowns (n = 2) were qualitatively analyzed by scanning electron microscope (SEM) and surface roughness (n = 5) was analyzed before and after the surface treatment (Ra parameter). The remaining crowns (n = 8) received standard repair with an adhesive system (Tetric N-Bond) and a nanohybrid CR (Tetric N-Ceram), and the microshear bond strength (SBS) test was performed (0.5 mm/min). Roughness and SBS data were analyzed by one- and two-way ANOVA, respectively, as well as Tukey’s post-test (α = 0.05). Results: Sandblasting with Al2O3 + PA resulted in the highest final roughness and SBS values. The lowest results were observed in the PA group, whereas the silane and diamond bur groups showed intermediate values. Conclusion: It may be concluded that indirect ceromer crowns sandblasted with aluminum oxide prior to PA etching promote increased roughness surface and bond strength values.


2014 ◽  
Vol 62 (4) ◽  
pp. 365-370 ◽  
Author(s):  
Ricardo Alves dos SANTOS ◽  
Eliane Alves de LIMA ◽  
Mônica Maria de Albuquerque PONTES ◽  
Alexandre Batista Lopes do NASCIMENTO ◽  
Marcos Antônio Japiassú Resende MONTES ◽  
...  

OBJECTIVE: To assess the bond strength to dentin of the Single Bond (3M ESPE) and XP Bond (Dentsply) total-etch and Adper SE Plus (3M ESPE) self-etch adhesive systems. METHODS: Fifteen healthy human third molars were randomly allocated across three different groups of five teeth each according to the adhesive system. The occlusal portion of each tooth was removed under refrigeration using a flexible diamond disc (EXTEC, Enfield, CT, USA) down to an area of dentin that did not reveal enamel, as confirmed under a 40X stereo microscope (Ramsor, São Paulo, Brazil). A standardized smear layer was created with #600 grit silicon-carbide paper. The adhesive systems were applied as per manufacturer recommendations, with the exception of the Adper SE Plus system, which was triple-polymerized. Composite resin blocks (5 mm) were placed on the dentin surface. The specimens were stored in distilled water for 24 hours at 37ºC. Using a flexible diamond disc (EXTEC, Enfield, CT, USA), toothpick-like specimens with an adhesive area of less than 1 mm² were obtained. A microtensile bond test was then carried out using a universal testing machine (KRATOS) with a crosshead speed of 0.5 mm/min. Analysis of variance (ANOVA) and Tukey's test were used for comparisons. RESULTS: The bond strength values obtained with each adhesive system were as follows: XP Bond, 96.24 MPa; Adper Single Bond, 72.39 MPa; Adper SE Plus, 49.91 MPa. CONCLUSION: In terms of bond strength to dentin, conventional adhesives outperform self-etching systems.