scholarly journals Influence of activation modes on diametral tensile strength of dual-curing resin cements

2005 ◽  
Vol 19 (4) ◽  
pp. 267-271 ◽  
Author(s):  
Renata Garcia Fonseca ◽  
Juliana Gomes dos Santos ◽  
Gelson Luis Adabo

In metallic restorations, the polymerization of dual-curing resin cements depends exclusively on chemical activation. The effect of the lack of photoactivation on the strength of these cements has been rarely studied. This study evaluated the influence of activation modes on the diametral tensile strength (DTS) of dual-curing resin cements. Base and catalyst pastes of Panavia F, Variolink II, Scotchbond Resin Cement, Rely X and Enforce were mixed and inserted into cylindrical metal moulds (4 x 2 mm). Cements were either: 1) not exposed to light (chemical activation = self-cured groups) or 2) photoactivated through mylar strips (chemical and photo-activation = dual-cured groups) (n = 10). After a 24 h storage in 37ºC distilled water, specimens were subjected to compressive load in a testing machine. A self-curing resin cement (Cement-It) and a zinc phosphate cement served as controls. Comparative analyses were performed: 1) between the activation modes for each dual-curing resin cement, using Student’s t test; 2) among the self-cured groups of the dual-curing resin cements and the control groups, using one-way ANOVA and Tukey’s test (alpha = 0.05). The dual-cured groups of Scotchbond Resin Cement (53.3 MPa), Variolink II (48.4 MPa) and Rely X (51.6 MPa) showed higher DTS than that of self-cured groups (44.6, 40.4 and 44.5 MPa respectively) (p < 0.05). For Enforce (48.5 and 47.8 MPa) and Panavia F (44.0 and 43.3 MPa), no significant difference was found between the activation modes (p > 0.05). The self-cured groups of all the dual-curing resin cements presented statistically the same DTS as that of Cement-It (44.1 MPa) (p > 0.05), and higher DTS than that of zinc phosphate (4.2 MPa). Scotchbond Resin Cement, Variolink II and Rely X depended on photoactivation to achieve maximum DTS. In the absence of light, all the dual-curing resin cements presented higher DTS than that of zinc phosphate and statistically the same as that of Cement-It (p > 0.05).

2003 ◽  
Vol 14 (3) ◽  
pp. 193-196 ◽  
Author(s):  
Simonides Consani ◽  
Julie Guzela dos Santos ◽  
Lourenço Correr Sobrinho ◽  
Mário Alexandre Coelho Sinhoreti ◽  
Manoel Damião Sousa-Neto

The relationship between metallic cast crowns and tensile strength according to cement types submitted to thermocycling was studied. Seventy-two metallic crowns were cast with Verabond II Ni-Cr alloy and cemented in standardized preparations with 10º tapering. Three types of finishing line (45-degree chamfered, 20-degree bevel shoulder and right shoulder) were made with diamond burs on bovine teeth. Twenty-four metallic crowns in each group were randomly subdivided into three subgroups of 8 samples each according to the cement used: SS White zinc phosphate cement, Vitremer resin-modified glass ionomer cement, and Rely X resin cement and were submitted to thermocycling. Retention was evaluated according to tensile load required to displace the metallic cast crowns from tooth preparations with an Instron testing machine. ANOVA and Tukey's test showed a statistically significant difference among luting materials, with greater results for Rely X resin cement (24.9 kgf) followed by SS White zinc phosphate cement (13.3 kgf) and Vitremer resin-modified glass ionomer cement (10.1 kgf). The finishing line types did not influence the tensile resistance of the crowns fixed with the three cements. Increased tensile resistance of metallic crowns fixed on bovine teeth was obtained with resin cement, independent of the finishing line types.


2020 ◽  
Vol 19 ◽  
pp. e208204
Author(s):  
Maria Helena Rossy Borges ◽  
Carmen Gilda Tavares Dias ◽  
Cristiane de Melo Alencar ◽  
Cecy Martins Silva ◽  
Renata Antunes Esteves

Aim: The purpose of this study was to compare the microhardness, diametral tensile strength, compressive strength and the rheological properties of self-adhesive versus conventional resin cements. Methods: Specimens of a conventional (RelyX ARC) and 3 self-adhesive (RelyX U200, Maxcem Elite, Bifix SE) types of resin cements were prepared. The Knoop test was used to assess the microhardness, using a Microhardness Tester FM 700. For the diametral tensile strength test, a tensile strength was applied at a speed of 0.6 mm/minute. A universal testing machine was used for the analysis of compressive strength and a thermo-controlled oscillating rheometer was used for the Rheology test. One-way ANOVA and Tukey’s test (α=0.05) were used for data analysis. Results: According to microhardness analysis, all the cements were statistically similar (p>0.05), except for Maxcem that presented lower hardness compared with the other cements in relation to the top surface (p<0.05). In the diametral tensile strength test, Relyx U200 and RelyX ARC cements were statistically similar (p>0.05), presented higher value when compared to the Maxcem and Bifix cements (p<0.05). The compressive strength of RelyX ARC and Maxcem Elite cements was statistically higher than RelyX U200 and Bifix cements (p<0.05). Regarding the rheology test, Maxcem Elite and RelyX ARC cements showed a high modulus of elasticity. Conclusions: The self-adhesive cements presented poorer mechanical properties than conventional resin cement. Chemical structure and types of monomers employed interfere directly in the mechanical properties of resin cements.


2004 ◽  
Vol 12 (4) ◽  
pp. 344-348 ◽  
Author(s):  
Eduardo Bresciani ◽  
Terezinha de Jesus Esteves Barata ◽  
Ticiane Cestari Fagundes ◽  
Akimi Adachi ◽  
Marina Martins Terrin ◽  
...  

The aim of this study was to compare, in different periods of time, the compressive and diametral tensile strength of a traditional high viscous glass ionomer cement: Fuji IX (GC Corporation), with two new Brazilian GIC's: Vitro-Molar (DFL) and Bioglass R (Biodinamica), all indicated for the Atraumatic Restorative Treatment (ART) technique. Fifteen disk specimens (6.0mm diameter x 3.0mm height) for the diametral tensile strength (DTS) test and fifteen cylindrical specimens (6.0mm diameter x 12.0mm height) for the compressive strength (CS) test were made of each GIC. Specimens were stored in deionized water at 37º C and 100% of humidity in a stove until testing. Five specimens of each GIC were submitted to CS and DTS test in each period, namely 1 hour, 24 hours and 7 days. The specimens were tested in a testing machine (Emic) at a crosshead speed of 1.0mm/min for CS and 0.5mm/min for the DTS test until failure occurred. The data were submitted to two-way ANOVA and Tukey tests (alpha=0.05). The mean CS values ranged from 42.03 to 155.47MPa and means DTS from 5.54 to 13.72 MPa, with test periods from 1h to 7 days. The CS and DTS tests showed no statistically significant difference between Fuji IX and Vitro Molar, except for CS test at 1-hour period. Bioglass R had lowest mean value for CS of the cements tested. In DTS test Bioglass R presented no statistically significant differences when compared with all others tested GICs at 1-hour period and Bioglass R presented no difference at 24-hour and 7-day periods when compared to Vitro-Molar. Further studies to investigate other physical properties such as fracture toughness and wear resistance, as well as chemical composition and biocompatibility, are now needed to better understand the properties of these new Brazilian GIC's.


2017 ◽  
Vol 15 (4) ◽  
pp. 258
Author(s):  
Marcelo Giannini ◽  
Andreia Assis Carvalho ◽  
Ariovaldo Stefani ◽  
Wladimir Franco de Sá Barbosa ◽  
Lawrence Gonzaga Lopes

Self-adhesive, dual-polymerizing resin cements require no treatment to the prepared tooth surfaces before cementation. Aim: The aim of this study was to evaluate the influence of curing mode on bond strength (BS) of three cementing systems to bovine dentin. Methods: The buccal enamel surfaces of 50 bovine incisors were removed to expose dentin and to flat the surface. The teeth were divided into five groups (n=10), which consisted of two resin cements (Multilink and Clearfil SA Cement) that were tested in dual- (halogen light for 40 s) and self-cured modes, and a control (RelyX ARC). Two cylinders of resin cements (1.0 mm X 0.75 mm) were prepared on each bonded dentin surface. After 24h at 37oC, resin cylinders were subjected to micro-shear testing in a universal testing machine (4411/Instron - 0.5 mm/min). Data were statistically analyzed by two-way ANOVA, Tukey and Dunnett`s test (5%). Results: Multilink showed higher BS than those observed on Clearfil SA. Light-curing resulted in higher BS for both Multilink and Clearfil SA. When Multilink was light-cured, no significant difference on BS was demonstrated between it and RelyX ARC. Conclusions: The highest BS values were obtained in control group and light-cured Multilink resin cement.


2013 ◽  
Vol 14 (4) ◽  
pp. 675-680
Author(s):  
Khalil Aleisa

ABSTRACT Statement of the problem Post retention is crucial factor in restoration survival. Posts are commonly failed due to loss of retention. It is unknown which luting agents would provide the maximum bond strength for Locator overdenture posts. Aim The aim of this study was to evaluate the bond retentive strengths of Locator overdenture posts cemented with 7 luting agents. Materials and methods One hundred and five single rooted human teeth were decoronated and randomly assigned to 7 groups (n = 15). Post spaces were prepared with Locator post drills to the depth of 6 mm. The Locator posts were cemented with Variolink II, RelyX ARC, Multilink N, RelyX Unicem, ParaCore, or MultiCore Flow resin luting agents. Zinc phosphate cement was served as control group. Specimens were stored in water at 37°C for 24 hours. Each specimen was loaded in tension in an Instron universal testing machine. The maximum force required to dislodge each Locator post was recorded. Means and standard deviations were calculated and data were statistically analyzed with one-way analysis of variance (ANOVA). Results The highest mean bond strength value for Locator posts was recorded for MultiCore® Flow group (mean = 550.1 N), while the lowest mean value was for RelyX Unicem™ resin cement group (mean = 216.8 N). A statistically significant difference in mean locator overdenture post bond strength was observed between the 7 cement types (p < 0.0001). ParaCore™ and MultiCore® Flow groups had significantly higher bond strength than all other groups, but they were not differed from each other. Conclusion Bond strength of Locator overdenture posts were influenced by the type of luting agents. MultiCore Flow and ParaCore resin cements offered the greatest retention. Clinical significance The type of luting agents had a significant effect on the retention of Locator posts. The use of Core buildup resin cements as luting agent with Locator post demonstrated the greatest retention. How to cite this article Aleisa K. Bond Strength of Overdenture Locator Posts Cemented with Seven Luting Agents. J Contemp Dent Pract 2013;14(4):675-680.


2017 ◽  
Vol 16 ◽  
pp. 1-7
Author(s):  
Bruna Genari ◽  
Vicente Castelo Branco Leitune ◽  
João Henrique Macedo Saucedo ◽  
Susana Maria Werner Samuel ◽  
Fabrício Mezzomo Collares

Self-adhesive, dual-polymerizing resin cements require no treatment to the prepared tooth surfaces before cementation. Aim: The aim of this study was to evaluate the influence of curing mode on bond strength (BS) of three cementing systems to bovine dentin. Methods: The buccal enamel surfaces of 50 bovine incisors were removed to expose dentin and to flat the surface. The teeth were divided into five groups (n=10), which consisted of two resin cements (Multilink and Clearfil SA Cement) that were tested in dual- (halogen light for 40 s) and self-cured modes, and a control (RelyX ARC). Two cylinders of resin cements (1.0 mm X 0.75 mm) were prepared on each bonded dentin surface. After 24h at 37oC, resin cylinders were subjected to micro-shear testing in a universal testing machine (4411/Instron - 0.5 mm/min). Data were statistically analyzed by two-way ANOVA, Tukey and Dunnett`s test (5%). Results: Multilink showed higher BS than those observed on Clearfil SA. Light-curing resulted in higher BS for both Multilink and Clearfil SA. When Multilink was light-cured, no significant difference on BS was demonstrated between it and RelyX ARC. Conclusions: The highest BS values were obtained in control group and light-cured Multilink resin cement.


2015 ◽  
Vol 16 (7) ◽  
pp. 559-564 ◽  
Author(s):  
Matheus Coelho Bandéca ◽  
Adriano Augusto Melo de Mendonça ◽  
Etevaldo Matos Maia Filho ◽  
Fausto da Silva Bramante ◽  
Darlon Martins Lima ◽  
...  

ABSTRACT This study evaluated the influence of relining fiber posts on the bond strength (BS) of resin cements in the root canal. Forty bovine teeth were divided in four groups (n = 10)G1 (ARC)—fiber post cemented with resin cement RelyX ARC; G2 (ARC+Z350)—relined fiber post cemented with RelyX ARC; G3 (U200)—fiber post cemented with self-adhesive cement RelyX U200; G4 (U200+Z350)—relined fiber post cemented with RelyX U200. The roots were sectioned in six 1.2-mm slices and the push-out test was performed. Data were analyzed by three-way analysis of variance (ANOVA), and Tukey's test (α = 0.05). For the conventional resin cement, there was no significant difference between groups G1-ARC (15.5 ± 3.8) and G2-ARC+Z350 (16.1 ± 4.5). For the self-adhesive cement, the results revealed higher BS values for relined posts G4-U200 + Z350 (19.9 ± 7.9) as compared to non-relined posts G3-U200 (14.4 ± 4.5). For both cements, in groups of relined posts, the apical and the cervical thirds presented similar BS. Relining enhances the performance of the self-adhesive resin cement, and the interaction between relining and root third influences the BS to the conventional resin cement. How to cite this article Conde DM, Rodrigues VP, de Fátima Carvalho Souza S, Bauer JRO, da Silva Bramante F, Lima SNL, Filho EMM, Bandeca MC, de Mendonça AAM, Lima DM. Influence of Relining Post on the Bond Strength of Resin Cements. J Contemp Dent Pract 2015;16(7):559-564.


2018 ◽  
Vol 29 (3) ◽  
pp. 268-274 ◽  
Author(s):  
Lara Almeida Cyrillo Cerqueira ◽  
Ana Rosa Costa ◽  
Ana Maria Spohr ◽  
Eduardo Miyashita ◽  
Benito André Silveira Miranzi ◽  
...  

Abstract The aim was to evaluate the influence of different dentin preparation mode in the smear layer characteristics (SL), hybrid layer (HL), and microtensile bond strength (µTBS) to dentin with two resin cements. The occlusal dentin of 120 third molars was exposed. The teeth were divided into 4 groups (n=30) according to the dentin preparation mode: 1- fine grain diamond bur; 2- coarse grain diamond bur; 3- multi laminate carbide steel bur; and, 4- ultrasonic CV Dentus diamond bur. Each treated dentin group was divided into 2 sub-groups (n=15) according to the resin cement: (1) RelyX U200 and (2) RelyX ARC. Resin composite blocks were cemented on dentin. After storage at 37o C for 24 h, beams with a cross section area of 1.0 mm2 were obtained, and tested in a universal testing machine at a crosshead speed of 0.5 mm/min. Two additional teeth for each sub-group were prepared to analyze the SL and HL on a scanning electron microscopy. According to Kruskal-Wallis test and Dunn tests, there was no significant difference in µTBS among the rotary instruments within each resin cement group. RelyX ARC obtained higher µTBS values compared to RelyX U200 (p<0.05). RelyX ARC formed evident HL, which was not observed for RelyX U200. The dentin mode preparation did not influence the µTBS of the resin cements. The SL was different for all instruments. The cementing agent is more determinant in the hybrid layer formation and bond strength to dentin than the instruments applied on dentin.


2018 ◽  
Vol 32 (3) ◽  
pp. 127 ◽  
Author(s):  
Gabriela De Souza Balbinot ◽  
Isadora Martini Garcia ◽  
Susana Maria Werner Samuel ◽  
Fabricio Mezzomo Collares ◽  
Vicente Castelo Branco Leitune

OBJECTIVE: The aim of this study was to evaluate the influence of octacalcium phosphate (OCP) addition to conventional glass ionomer cement (GIC).METHODOLOGY: A commercial glass ionomer cement (Vidrion R – S.S. White Artigos Dentários Ltda – Rio de Janeiro, Brazil) was used in this study. OCP was added to powder in 1.5 and 3 wt%. GIC without OCP addition was used as control. Specimens were produced to evaluate radiopacity, setting time and diametral tensile strength of cements. Radiopacity was assessed by phosphor plate system with alluminium step-wedge for comparison. For setting time determination, Gilmore needle (100 g) was used to determine final setting reaction. Diametral tensile strength was measured in a universal testing machine. Data were analyzed by one-way ANOVA at a significance level of 95%.RESULTS: Results showed no statistically significant difference in tested properties with octacalcium phosphate addition in any concentration.CONCLUSION: OCP addition to GIC did not influence materials properties.


2021 ◽  
Vol 9 (D) ◽  
pp. 155-159
Author(s):  
Waleed Alqahtani ◽  
Rami Mohammed Galal ◽  
Ghada Hamza

Purpose: The aim of this study is to investigate the effect of the curing modes of two adhesive resin cements (Light cure mode of the Variolink Veneer, the self-cure mode and dual cure mode of the Multilink Automix) on the marginal leakage of lithium disilicate ceramic laminate veneers. Methods: A total number of forty eight extracted natural central incisors were prepared to receive ceramic laminate veneers, constructed using E-max ceramic divided into three groups cemented using three curing modes of two adhesive resin cements {light-cure mode of Variolink Veneer, self-cure mode of Multilink Automix and dual-cure mode of Multilink Automix adhesive resin cements} . Die penetration test was done using the methylene blue stain {qualitative assessment} for testing the die penetration along the tooth/ceramic interface. Results: Descriptive statistical analysis revealed that the self-curing mode recorded the significantly least degree of leakage compared to the light and dual cure modes.  The self-cure mode recorded (0.1±0.3) which was significantly lower than light cure (1.2 ±0.9) and dual cure mode (1.2 ±0.4), there was no statistical significant difference between the later two curing modes. The self-cure mode of the resin cement is considered a more effective method for having the least marginal leakage at the tooth/ceramic interface. There was no difference between the light cure mode and the dual cure mode.


Sign in / Sign up

Export Citation Format

Share Document