FOREIGN-GAS FILM COOLING ALONG NONCONVERGING AMD CONVERGING WALLS AT VARIOUS FREE-STREAM TURBULENCE LEVELS

Author(s):  
Eliyahu Talmor ◽  
N. Weber
Author(s):  
Vinod U. Kakade ◽  
Steven J. Thorpe ◽  
Miklós Gerendás

The thermal management of aero gas turbine engine combustion systems commonly employs effusion-cooling in combination with various cold-side convective cooling schemes. The combustor liner incorporates many small holes which are usually set in staggered arrays and at a shallow angle to the cooled surface; relatively cold compressor delivery air is then allowed to flow through these holes to provide the full-coverage film-cooling effect. The efficient design of such systems requires robust correlations of film-cooling effectiveness and heat transfer coefficient at a range of aero-thermal conditions, and the use of appropriately validated computational models. However, the flow conditions within a combustor are characterised by particularly high turbulence levels and relatively large length scales. The experimental evidence for performance of effusion-cooling under such flow conditions is currently sparse. The work reported here is aimed at quantifying typical effusion-cooling performance at a range of combustor relevant free-stream conditions (high turbulence), and also to assess the importance of modeling the coolant to free-stream density ratio. Details of a new laboratory wind-tunnel facility for the investigation of film-cooling at high turbulence levels are reported. For a typical combustor effusion geometry that uses cylindrical holes, spatially resolved measurements of adiabatic effectiveness, heat transfer coefficient and net heat flux reduction are presented for a range of blowing ratios (0.48 to 2), free-stream turbulence conditions (4 and 22%) and density ratios (0.97 and 1.47). The measurements reveal that elevated free-stream turbulence impacts on both the adiabatic effectiveness and heat transfer coefficient, although this is dependent upon the blowing ratio being employed and particularly the extent to which the coolant jets detach from the surface. At low blowing ratios the presence of high turbulence levels causes increased lateral spreading of the coolant adjacent to the injection points, but more rapid degradation in the downstream direction. At high blowing ratios, high turbulence levels cause a modest increase in effectiveness due to turbulent transport of the detached coolant fluid. Additionally, the augmentation of heat transfer coefficient caused by the coolant injection is seen to be increased at high free-stream turbulence levels.


Author(s):  
Donald L. Schmidt ◽  
David G. Bogard

A flat plate test section was used to study how high free-stream turbulence with large turbulence length scales, representative of the turbine environment, affect the film cooling adiabatic effectiveness and heat transfer coefficient for a round hole film cooling geometry. This study also examined cooling performance with combined high free-stream turbulence and a rough surface which simulated the roughness representative of an in-service turbine. The injection was from a single row of film cooling holes with injection angle of 30°. The density ratio of the injectant to the mainstream was 2.0 for the adiabatic effectiveness tests, and 1.0 for the heat transfer coefficient tests. Streamwise and lateral distributions of adiabatic effectiveness and heat transfer coefficients were obtained at locations from 2 to 90 hole diameters downstream. At small to moderate momentum flux ratios, which would normally be considered optimum blowing conditions, high free-stream turbulence dramatically decreased adiabatic effectiveness. However, at large momentum flux ratios, conditions for which the film cooling jet would normally be detached, high free-stream turbulence caused an increase in adiabatic effectiveness. The combination of high free-stream turbulence with surface roughness resulted in an increase in adiabatic effectiveness relative to the smooth wall with high free-stream turbulence. Heat transfer rates were relatively unaffected by a film cooling injection. The key result from this study was a substantial increase in the momentum flux ratios for maximum film cooling performance which occurred for high free-stream turbulence and surface roughness conditions which are more representative of actual turbine conditions.


2018 ◽  
Vol 16 ◽  
pp. 30-44 ◽  
Author(s):  
Farouk Kebir ◽  
Azzeddine Khorsi

Film cooling is vital for gas turbine blades to protect them from thermal stresses and high temperatures due to the hot gas flow in the blade surface. Film cooling is applied to almost all external surfaces associated with aerodynamic profiles that are exposed to hot combustion gases such as main bodies, end-walls, blade tips and leading edges. In a review of the literature, it was found that there are strong effects of free-stream turbulence, surface curvature and hole shape on film cooling performance also blowing ratio. The performance of the film cooling is difficult to predict due to the inherent complex flow fields along the surfaces of the airfoil components in the turbine engines. From all what we introducing the film cooling is reviewed through a discussion of the analyses methodologies, a physical description, and the various influences on film-cooling performance. Initially Computational analysis was done on a flat plate with hole inclined at 55° to the surface plate. This study focuses on the efficient computation of film cooling flows with three blowing ratio. The numerical results show the effectiveness cooling and heat transfer behavior with increasing injection blowing ratio M (0.5, 1, and 1.5). The influence of increased blade film cooling can be assessed via the values of Nusselt number in terms of reduced heat transfer to the blade. Predictions of film effectiveness are compared with experimental results for a circular jet at blowing ratios ranging from 0.5, 1.0 and 1.5. The present results are obtained at a free stream turbulence of 10%, which are the typical conditions upstream of the effectiveness is generally lower for a large stream-wise angle of 55°.


Author(s):  
Michael W. Cruse ◽  
Ushio M. Yuki ◽  
David G. Bogard

Film cooling adiabatic effectiveness of a simulated turbine airfoil leading edge was studied experimentally. The leading edge had two rows of holes, one at nominally the stagnation line position and the second a few hole diameters downstream. Hole positions at the leading edge, and inclination of the holes with respect to the surface, were different than typically used in previous studies, but were representative of current design practice. Various leading edge film cooling parameters were investigated including stagnation line position, free-stream turbulence level, leading edge geometry, and coolant to mainstream density ratio. Large density ratios were obtained by cooling the injected coolant to very low temperatures. Large scale, high level free-stream turbulence (Tu = 20%) was generated using a specially developed cross-jet turbulence generator. An infrared camera system was used to obtain well resolved surface temperature distributions around the coolant holes and across the leading edge. Results from the experiments showed considerably higher optimum blowing ratios than found in previous studies. The stagnation line position was found to be important in influencing the direction of coolant flow from the first row of holes. High free-stream turbulence levels were found to greatly decrease adiabatic effectiveness at low blowing ratios (M = 1.0), but had little effect at high blowing ratios (M = 2.0 and 2.5). Adiabatic effectiveness distributions were very similar for circular and elliptical leading edges. Experiments conducted at coolant to mainstream density ratios of 1.1 and 1.8 showed distinctly different flow characteristics in the stagnation line region for the different density ratio coolants.


Author(s):  
Savas Yavuzkurt ◽  
Jawad S. Hassan

The capabilities of four two-equation turbulence models in predicting film cooling effectiveness under high free stream turbulence (FST) intensity (Tu = 10%) were investigated and their performance are presented and discussed. The four turbulence models are: the standard k-ε, RNG, and realizable k-ε models as well as the standard k-ω model all four found in the FLUENT CFD code. In all models, the enhanced wall treatment has been used to resolve the flow near solid boundaries. A systematic approach has been followed in the computational setup to insure grid-independence and accurate solution that reflects the true capabilities of these models. Exact geometrical and flow-field replicas of an experimental study on discrete hole film cooling were generated and used in FLUENT. A pitch-to-diameter ratio of 3.04, injection tube length-to-diameter ratio of 4.6 and density ratios of 0.92 and 0.97 were some of the parameters used in the film cooling analysis. The study covered two levels of blowing ratios (M = 0.5 and 1.5) at an environment of what is defined as high initial free-stream turbulence intensity (Tu = 10%). Performance of these models under a very low initial FST were presented in a paper by the authors in Turbo Expo 2006. In that case, the standard k-ε model had the most consistent performance among all considered turbulence models and the best centerline film cooling effectiveness predictions under very low FST. However, after the addition of high FST in the free-stream, even the standard k-ε model started to deviate greatly from the experimental data (up to 200% over-prediction) under high blowing ratios (M = 1.5). The model which performed the best under high FST but low blowing ratios (M = 0.5) is still the standard k-ε model. In all cases only standard k-ε model results match the trends of data for both cases. It can be said that under high FST with high M all the models do not do a good job of predicting the data. It was concluded that these deviations resulted from the effects of both high FST and high M. Under high M, near the injection holes deviations could result from the limitations of Boussinesq hypothesis relating the direction of Reynolds stress to the mean strain rate. Also, it seems like all models have trouble including the effects of high FST by not being able to take into account high levels of diffusion of turbulence from the free stream. However, standard k-ε model still looks like the best candidate for further improvement with the addition of new diffusion model for TKE under high FST.


1979 ◽  
Vol 101 (2) ◽  
pp. 298-304 ◽  
Author(s):  
K. Kadotani ◽  
R. J. Goldstein

The effects of boundary layer thickness, Reynolds number and free stream turbulence intensity on jets issuing from a row of inclined holes are investigated from the viewpoint of film cooling. The local film cooling effectiveness and mean velocity and mean temperature distributions are measured. The turbulent eddy diffusivities are evaluated from calculations based on a heat source model. The boundary layer thickness and the free stream turbulence significantly influence the jet-mainstream interaction process and consequently the film cooling performance.


1996 ◽  
Vol 118 (2) ◽  
pp. 327-333 ◽  
Author(s):  
H. Wanda Jiang ◽  
J.-C. Han

Experiments were performed to study the effect of film hole row location on local film effectiveness distribution of a turbine blade model with air or CO2 film injection. Tests were performed on a five-blade linear cascade at the chord Reynolds number of 3.0 × 105 at the cascade inlet. A combination of turbulence grid and unsteady wake was used to create a higher free-stream turbulence level. The test blade had three rows of film holes in the leading edge region and two rows each on the pressure and suction surfaces. Film hole row locations were set by leaving the film holes at that row location open and covering the remaining rows. In addition, the additive nature of film cooling on the turbine blade model was examined by comparing the measured film effectiveness with the predicted effectiveness from the superposition method. Results show that injection from a different film hole row location provides a different effectiveness distribution on pressure and suction surfaces depending on local mainstream velocity and blade curvature. In most cases, the superposition method holds downstream of the last film hole row.