scholarly journals On the in-plane shear response of the high bond strength concrete masonry walls

2017 ◽  
Vol 50 (5) ◽  
Author(s):  
M. Dhanasekar ◽  
J. A. Thamboo ◽  
S. Nazir
2018 ◽  
Vol 144 (6) ◽  
pp. 04018055 ◽  
Author(s):  
Ernesto S. Fortes ◽  
Guilherme A. Parsekian ◽  
Fernando S. Fonseca ◽  
Jefferson S. Camacho

2017 ◽  
Vol 136 ◽  
pp. 245-260 ◽  
Author(s):  
Reza Hassanli ◽  
Mohamed A. ElGawady ◽  
Julie E. Mills

Author(s):  
J. Wei ◽  
S. S. Deng ◽  
C. M. Tan

Silicon-to-silicon wafer bonding by sol-gel intermediate layer has been performed using acid-catalyzed tetraethylthosilicate-ethanol-water sol solution. High bond strength near to the fracture strength of bulk silicon is obtained at low temperature, for example 100°C. However, The bond efficiency and bond strength of this intermediate layer bonding sharply decrease when the bonding temperature increases to elevated temperature, such as 300 °C. The degradation of bond quality is found to be related to the decomposition of residual organic species at elevated bonding temperature. The bubble generation and the mechanism of the high bond strength at low temperature are exploited.


Materials ◽  
2020 ◽  
Vol 13 (10) ◽  
pp. 2424
Author(s):  
Sebastián Calderón ◽  
Laura Vargas ◽  
Cristián Sandoval ◽  
Gerardo Araya-Letelier

Eight partially grouted (PG-RM) concrete masonry walls were tested to study the influence of the strength and width of blocks, the wall aspect ratio, the horizontal and vertical reinforcement ratio, and the presence of edge elements (flanges). The results were analyzed in terms of the failure mode, damage progression, shear strength, lateral stiffness degradation, equivalent viscous damping ratio, and displacement ductility. Additionally, the performances of some existing shear expressions were analyzed by comparing the measured and predicted lateral load capacity of the tested walls. Based on the results, a slight increment in the lateral stiffness was achieved when employing stronger blocks, while the shear strength remained constant. Besides, increasing the width of concrete blocks did not have a significant effect on the shear strength nor in the initial tangential stiffness, but it generated a softer post-peak strength degradation. Increasing the wall aspect ratio reduced the brittleness of the response and the shear strength. Reducing the amount of vertical reinforcement lowered the resulting shear strength, although it also slowed down the post-peak resistance degradation. Transversal edge elements provided integrity to the wall response, generated softer resistance degradation, and improved the symmetry of the response, but they did not raise the lateral resistance.


Sign in / Sign up

Export Citation Format

Share Document