scholarly journals Experimental evaluation of tensile strength test methods for steel fibre-reinforced concrete

2019 ◽  
Vol 71 (8) ◽  
pp. 385-394 ◽  
Author(s):  
Hussam A. Goaiz ◽  
Nabeel A. Farhan ◽  
M. Neaz Sheikh ◽  
Tao Yu ◽  
Muhammad N. S. Hadi
2021 ◽  
Vol 15 (1) ◽  
pp. 81-92
Author(s):  
Constantinos B. Demakos ◽  
Constantinos C. Repapis ◽  
Dimitros P. Drivas

Aims: The aim of this paper is to investigate the influence of the volume fraction of fibres, the depth of the beam and the shear span-to-depth ratio on the shear strength of steel fibre reinforced concrete beams. Background: Concrete is a material widely used in structures, as it has high compressive strength and stiffness with low cost manufacturing. However, it presents low tensile strength and ductility. Therefore, through years various materials have been embedded inside it to improve its properties, one of which is steel fibres. Steel fibre reinforced concrete presents improved flexural, tensile, shear and torsional strength and post-cracking ductility. Objective: A better understanding of the shear performance of SFRC could lead to improved behaviour and higher safety of structures subject to high shear forces. Therefore, the influence of steel fibres on shear strength of reinforced concrete beams without transverse reinforcement is experimentally investigated. Methods: Eighteen concrete beams were constructed for this purpose and tested under monotonic four-point bending, six of which were made of plain concrete and twelve of SFRC. Two different aspect ratios of beams, steel fibres volume fractions and shear span-to-depth ratios were selected. Results: During the experimental tests, the ultimate loading, deformation at the mid-span, propagation of cracks and failure mode were detected. From the tests, it was shown that SFRC beams with high volume fractions of fibres exhibited an increased shear capacity. Conclusion: The addition of steel fibres resulted in a slight increase of the compressive strength and a significant increase in the tensile strength of concrete and shear resistance capacity of the beam. Moreover, these beams exhibit a more ductile behaviour. Empirical relations predicting the shear strength capacity of fibre reinforced concrete beams were revised and applied successfully to verify the experimental results obtained in this study.


2014 ◽  
Vol 5 (1) ◽  
pp. 9-19
Author(s):  
I. Kovács

Abstract The papers of the series deal with experimental characterisation of mechanical as well as structural properties of different steel fibre reinforced concretes that can be used for several structural applications. An extensive experimental programme (six years) has been developed to investigate the effect of steel fibre reinforcement on the mechanical performance and structural behaviour of concrete specimens. Specimens and test methods were selected to be able to detect realistic behaviour of the material, representing clear effect on the structural performance. Material compositions, test methods, type of test specimens will be detailed in the presented paper (Part I). Furthermore, compressive strength (Part II), stress-strain relationship (Part II), splitting strength (Part III) and toughness (Part IV) will also be discussed. In the light of the motivation to determine the structural performances of 1D concrete structural element affected by steel fibre reinforcement, bending and shear behaviour (Part V) as well as serviceability state (Part VI) of steel fibre reinforced concrete beams will be analysed. Since normal force — prestressing force — can affectively be used to improve the structural performances of RC element flexural tests were carried out on prestressed pretensioned steel fibre reinforced concrete beams (Part VII). Moreover, focusing on the in-plane state of stresses for 2D structures, behaviour of steel fibre reinforced concrete deep beams in shear and steel fibre reinforced concrete slabs (Part VIII) in bending will be explained. Finally, based on the wide range of the experimental and analytical studies on the presented field, a new material model for the 1D uniaxial behaviour (Part IX) and its possible extension to the 3D case (Part X) will be described hereafter. All papers will put emphasis on the short literature review of the last four decades.


Author(s):  
Fangyuan Li ◽  
Yunxuan Cui ◽  
Chengyuan Cao ◽  
Peifeng Wu

Directionally distributed steel fibre-reinforced concrete has been proposed as a novel concrete because of its high tensile strength and crack resistance in specific directions. Based on the existing studies of the effect of the fibre direction on the mechanical properties of fibre-reinforced concrete, the authors in this paper performed further studies of the mechanical properties of directionally distributed steel fibre-reinforced concrete by conducting split tensile and bending tests. The split tensile strength of the directionally distributed fibre-reinforced concrete clearly exhibited anisotropy. The split tensile strength perpendicular to the fibre direction was much higher than that parallel to the fibre direction. The split tensile strength perpendicular to the fibre direction was almost twice the tensile strength of plain concrete. The flexural performance of directionally distributed fibre-reinforced concrete in the fibre direction significantly improved compared to that of randomly distributed fibre-reinforced concrete. Specifically, the flexural strength increased by as much as 97%. Gravity resulted in a deviation in the tensile properties of concrete prepared by manually and directionally placing fibres in a layered casting process. The test results can be utilised in subsequent concrete designs. The conclusions reached in this paper provide comprehensive mechanical design parameters for the application of directionally distributed fibre-reinforced concrete.


2017 ◽  
Vol 259 ◽  
pp. 52-57
Author(s):  
Jan Fleissig

The steel fibre reinforced concrete is expensive compared with the ordinary concrete. The costs for the production, the transport and the setting of steel fibre reinforced concrete should be directly proportional to its quality. The quality of material can be quantified in a broad spectrum of properties (the workability, the mechanical and physical properties, the durability, etc.). This article is focused on the influence of mechanical and physical properties (the tensile strength and the residual tensile strength) on ULS and SLS. The paper is limited only to the bending load bearing capacity from ULS point of view and limited only to vertical deformation from SLS point of view. The example is a part of paper – the calculation of two bending structures. Firstly, it is calculated as the structure of ordinary reinforced concrete and secondly it is calculated as the structure of reinforced steel fibre reinforced concrete. The geometric arrangement, the type and the quantity of reinforcement are identical for both calculated structures. The calculated structures are different only in the tensile strength and the residual tensile strength. All other input parameters (including modulus of elasticity) are identical for both calculated structures, in order the influence of tensile strength on ULS and SLS excels. The presented results should be the basic concept for the effectiveness assessment of steel fibre reinforced concrete application.


2014 ◽  
Vol 2014 ◽  
pp. 1-10 ◽  
Author(s):  
M. P. Singh ◽  
S. P. Singh ◽  
A. P. Singh

Results of an investigation conducted to study the effect of fibre hybridization on the strength characteristics such as compressive strength, split tensile strength, and water permeability of steel fibre reinforced concrete (SFRC) are presented. Steel fibres of different lengths, that is, 12.5 mm, 25 mm, and 50 mm, having constant diameter of 0.6 mm, were systematically combined in different mix proportions to obtain mono, binary, and ternary combinations at each of 0.5%, 1.0%, and 1.5% fibre volume fraction. A concrete mix containing no fibres was also cast for reference purpose. A total number of 1440 cube specimens of size 100*100*100 mm were tested, 480 each for compressive strength, split tensile strength, and water permeability at 7, 28, 90, and 120 days of curing. It has been observed from the results of this investigation that a fibre combination of 33% 12.5 mm + 33% 25 mm + 33% 50 mm long fibres can be adjudged as the most appropriate combination to be employed in hybrid steel fibre reinforced concrete (HySFRC) for optimum performance in terms of compressive strength, split tensile strength and water permeability requirements taken together.


2019 ◽  
Vol 26 (4) ◽  
pp. 197-208
Author(s):  
Leo Gu Li ◽  
Albert Kwok Hung Kwan

Previous research studies have indicated that using fibres to improve crack resistance and applying expansive agent (EA) to compensate shrinkage are both effective methods to mitigate shrinkage cracking of concrete, and the additions of both fibres and EA can enhance the other performance attributes of concrete. In this study, an EA was added to fibre reinforced concrete (FRC) to produce concrete mixes with various water/binder (W/B) ratios, steel fibre (SF) contents and EA contents for testing of their workability and compressive properties. The test results showed that adding EA would slightly increase the superplasticiser (SP) demand and decrease the compressive strength, Young’s modulus and Poisson’s ratio, but significantly improve the toughness and specific toughness of the steel FRC produced. Such improvement in toughness may be attributed to the pre-stress of the concrete matrix and the confinement effect of the SFs due to the expansion of the concrete and the restraint of the SFs against such expansion.


2014 ◽  
Vol 5 (2) ◽  
pp. 119-125
Author(s):  
I. Kovács

The present paper of a series deals with the experimental characterisation of flexural toughness properties of structural concrete containing different volume of hooked-end steel fibre reinforcement (75 kg/m3, 150 kg/m3). Third-point flexural tests were carried out on steel fibre reinforced concrete beams having a cross-section of 80 mm × 85 mm with the span of 765 mm, hence the shear span to depth ratio was 3. Beams were sawn out of steel fibre reinforced slab elements (see Part I) in order to take into consideration the introduced privilege fibre orientation (I and II) and the position of the beam (Ba-a, Ba-b, Ba-c) before sawing (see Part I). Flexural toughness properties were determined considering different standard specifications, namely the method of the ASTM (American Standards for Testing Materials), the process of the JSCE (Japan Society of Civil Engineering), and the final proposal of Banthia and Trottier for the post cracking strength. Consequently, behaviour of steel fibre reinforced concrete was examined in bending taking into consideration different experimental parameters such as fibre content, concrete mix proportions, fibre orientation, positions of test specimens in the formwork, while experimental constants were the size of specimens, the type of fibre used and the test set-up and test arrangement.


Sign in / Sign up

Export Citation Format

Share Document