scholarly journals Ultrasound technologies in the diagnosis, treatment, and rehabilitation of children with testicular torsion

2021 ◽  
Vol 11 (3) ◽  
pp. 351-358
Author(s):  
Svetlana Yu. Komarova ◽  
Natalya A. Tsap ◽  
Il’ya A. Karachev

AIM: This study improves the diagnosis of testicular inversion in children to select different treatment strategies by determining the effectiveness of conservative and surgical testicular detorsion criteria. MATERIALS AND METHODS: The clinical data from 2010 to 2020 included 110 children with testicular torsion. In 64% of cases, the left testicle predominated. Testicular torsion occurred in 50% of children in the 12- to 14-year-old age group. The time from disease onset to seeking medical help ranged from 1.5 hours to 11 days. It was less than 6 hours in 41.8% of children, from 6 to 12 hours in 13.6% of boys, 12 to 24 hours in 11% of patients, and more than 24 hours in 33.6% of boys and adolescents. The protocol for the diagnosis, treatment and rehabilitation of all children included various techniques for ultrasound examination of the scrotal organs. RESULTS: The analysis showed the absence of reliable criteria for detecting testicle torsion in the early periods (61%100%): spiral course of the spermatic vessels (63.9%), change in the position of the testicle (19.8%), increase in the volume of the testicle and appendage (98.3%), a change in testicle shape and the inability to withdraw its poles (47.5%), and a hydrocele (67.2%). The index of false-negative results of the ultrasound scan of the scrotal organs reaches 40%. Conservative navigation detorsion was performed in 39 (35.5%) boys and adolescents during the early disease stages. The ultrasound criteria for the effectiveness of conservative detorsion were established. The main criteria normalized blood flow in the testis (100%). Surgical treatment of testicular inversion was performed in 71 (64.5%) boys and adolescents. CONCLUSIONS: Compliance with the protocol for diagnosing, treating, and rehabilitating children in different age groups with testicular torsion allowed us to determine adequate emergency treatment strategies and follow-up. An ultrasound differential diagnosis is performed with testicular hydatid torsion and inflammatory diseases of the scrotal organs. The informativeness of the ultrasound methods amounted to 60%.

2021 ◽  
pp. 82-90
Author(s):  
N. A. Sholokhova

The aim of this study was to determine the diagnostic capabilities of various methods of radiological diagnostics for lesions of the metaphyses and epiphyses of bones in newborns and young children.The study involved 108 children in the age group 5 days – 12 months with pathological changes in the pineal gland and bone metaphysis. The possibilities and advantages of standard radiography (СR), ultrasound examination (US) and magnetic resonance imaging (MRI) in the early and differential diagnosis of the osteomyelitis process and epiphyseolysis have been determined. High sensitivity (98 %), specificity (99 %) and accuracy (98 %) for ultrasound and sensitivity (94 %), specificity (89 %) and accuracy (95 %) of MRI in diagnosing osteomyelitis in patients of this age groups. At the same time, the possibilities of standard radiography at the stages of early diagnosis of inflammatory processes in the distal parts of the bones were limited due to a number of factors. The use of diagnostic algorithms greatly facilitates the work of a radiologist and reduces the number of false negative results during the initial treatment of patients.


1984 ◽  
Vol 30 (2) ◽  
pp. 301-303 ◽  
Author(s):  
T G Rosano

Abstract Pediatric patients (to age 18) without neuroblastoma show an age-related decrease in urinary excretion of each of the catecholamines--epinephrine, norepinephrine, and dopamine--in relation to creatinine excretion. From these data, I have developed reference intervals for pediatric age groups. Application of these ranges to seven patients with neuroblastoma and ganglioneuroblastoma indicated a high clinical sensitivity for the urinary dopamine determination but significant false-negative results for epinephrine and norepinephrine.


1974 ◽  
Vol 31 (02) ◽  
pp. 273-278
Author(s):  
Kenneth K Wu ◽  
John C Hoak ◽  
Robert W Barnes ◽  
Stuart L Frankel

SummaryIn order to evaluate its daily variability and reliability, impedance phlebography was performed daily or on alternate days on 61 patients with deep vein thrombosis, of whom 47 also had 125I-fibrinogen uptake tests and 22 had radiographic venography. The results showed that impedance phlebography was highly variable and poorly reliable. False positive results were noted in 8 limbs (18%) and false negative results in 3 limbs (7%). Despite its being simple, rapid and noninvasive, its clinical usefulness is doubtful when performed according to the original method.


2020 ◽  
Vol 13 (1) ◽  
pp. 413-414 ◽  
Author(s):  
Mohamed Farouk Allam

Due to the international spread of COVID-19, the difficulty of collecting nasopharyngeal swab specimen from all suspected patients, the costs of RT-PCR and CT, and the false negative results of RT-PCR assay in 41% of COVID-19 patients, a scoring system is needed to classify the suspected patients in order to determine the need for follow-up, home isolation, quarantine or the conduction of further investigations. A scoring system is proposed as a diagnostic tool for suspected patients. It includes Epidemiological Evidence of Exposure, Clinical Symptoms and Signs, and Investigations (if available). This scoring system is simple, could be calculated in a few minutes, and incorporates the main possible data/findings of any patient.


2020 ◽  
Vol 18 ◽  
Author(s):  
Pegah Shakib ◽  
Mohammad Reza Zolfaghari

Background: Conventional laboratory culture-based methods for diagnosis of Streptococcus pneumoniae are time-consuming and yield false negative results. Molecular methods including real-time (RT)-PCR rapid methods and conventional PCR due to higher sensitivity and accuracy have been replaced instead traditional culture assay. The aim of the current study was to evaluate lytA gene for detection of Streptococcus pneumoniae in the cerebrospinal fluid of human patients with meningitis using real-time PCR assay. Material and Methods: In this cross-sectional study, a total of 30 clinical specimens were collected from patients in a period from September to December 2018. In order to evaluate the presence of lytA gene, conventional and real-time PCR methods were used without culture. Results: From 30 sputum samples five (16.66%) isolates were identified as S. pneumoniae by lytA PCR and sequencing. Discussion: In this research, an accurate and rapid real-time PCR method was used, which is based on lytA gene for diagnosis of bacteria so that it can be diagnosed. Based on the sequencing results, the sensitivity for detection of lytA gene was 100% (5/5).


Coronaviruses ◽  
2020 ◽  
Vol 01 ◽  
Author(s):  
Maria Silvia De Feo ◽  
Viviana Frantellizzi ◽  
Giuseppe De Vincentis

Background: We present the case of a 55-year-old woman, admitted to the Infectious Disease Department of Policlinico Umberto I, Rome, in mid-March 2020, with suspicion of COVID-19 infection. Objective: The rRT-PCR was negative and the following CT scan, performed to exclude false-negative results and help diagnosis, was inconclusive. Methods: It was decided to submit the patient to 99mTc-HMPAO-labelled leukocyte scan. Results: This exam led to the diagnosis of infective endocarditis. Conclusion: In the present pandemic scenario, 99mTc-HMPAO-labelled leukocyte scan represents a reliable imaging technique for differential diagnosis with COVID-19 in patients with confusing clinical signs, possible false-negative rRT-PCR results and inconclusive CT scan.


Author(s):  
Hyoung-Jin Moon ◽  
Won Lee ◽  
Ji-Soo Kim ◽  
Eun-Jung Yang ◽  
Hema Sundaram

Abstract Background Aspiration testing before filler injection is controversial. Some believe that aspiration can help prevent inadvertent intravascular injection, while others cite false-negative results and question its value given that the needle position always changes somewhat during injection procedures. Objectives To test the relation of false-negative results to the viscosity of the material within the needle lumen and determine whether a less viscous material within the needle lumen could decrease the incidence of false-negative results. Methods In vitro aspiration tests were performed using 30-G and 27-G needle gauges, two cross-linked hyaluronic acid fillers, normal saline bags pressurized at 140 and 10 mmHg to mimic human arterial and venous pressures, and three needle lumen conditions (normal saline, air, and filler). Testing was repeated three times under each study condition (72 tests in total). For in vivo correlation, aspiration tests were performed on femoral arteries and central auricular veins in three rabbits (4–5 aspirations per site, 48 tests in total). Results In vitro and in vivo testing using 30-G needles containing filler both showed false-negative results on aspiration testing. In vitro and in vivo testing using needles containing saline or air showed positive findings. Conclusions False-negative results from aspiration testing may be reduced by pre-filling the needle lumen with saline rather than a filler. The pressurized system may help overcome challenges of animal models with intravascular pressures significantly different from those of humans. The adaptability of this system to mimic various vessel pressures may facilitate physiologically relevant studies of vascular complications.


Viruses ◽  
2021 ◽  
Vol 13 (5) ◽  
pp. 730
Author(s):  
Magda Rybicka ◽  
Ewa Miłosz ◽  
Krzysztof Piotr Bielawski

At present, the RT-PCR test remains the gold standard for early diagnosis of SARS-CoV-2. Nevertheless, there is growing evidence demonstrating that this technique may generate false-negative results. Here, we aimed to compare the new mass spectrometry-based assay MassARRAY® SARS-CoV-2 Panel with the RT-PCR diagnostic test approved for clinical use. The study group consisted of 168 suspected patients with symptoms of a respiratory infection. After simultaneous analysis by RT-PCR and mass spectrometry methods, we obtained discordant results for 17 samples (10.12%). Within fifteen samples officially reported as presumptive positive, 13 were positive according to the MS-based assay. Moreover, four samples reported by the officially approved RT-PCR as negative were positive in at least one MS assay. We have successfully demonstrated superior sensitivity of the MS-based assay in SARS-CoV-2 detection, showing that MALDI-TOF MS seems to be ideal for the detection as well as discrimination of mutations within the viral genome.


Sign in / Sign up

Export Citation Format

Share Document