scholarly journals Effect of foundation compliance on earthquake stresses in multistory buildings*

1954 ◽  
Vol 44 (4) ◽  
pp. 551-569
Author(s):  
R. G. Merritt ◽  
G. W. Housner

Abstract This paper shows the quantitative effect that foundation compliance has on the maximum base shear force and the fundamental period of vibration in typical tall buildings subjected to strong-motion earthquakes. A study was made of five-, ten-, and fifteen-story building models on the Electric Analog Computer, subjecting them to the ground accelerations of actual earthquakes. The base shear forces were measured, the foundation compliance of the models being changed through a very wide range. The properties specified for the building models are shown to be similar to the properties found in real buildings. The experimental results imply that the maximum base shear forces in typical buildings of five stories and higher during strong-motion earthquakes will be essentially unaffected by any degree of foundation compliance that can be expected in normal building practice. The fundamental period of typical buildings will be increased by about 10 per cent if the foundation compliance is the maximum that can be expected in standard building practice.

Author(s):  
Rajdip Paul ◽  
Sujit Kumar Dalui

The present paper focuses on the study of wind-induced responses of cross-plan shaped tall buildings. Initially, three parametric building models are studied for the purpose with a constant plan area 22500 mm2. The length and velocity scales are taken as 1:300 and 1:5, respectively. Wind angle of attack (WAA) is considered from 0° to 330° with an increment of 30°. At first, the external surface pressure coefficients (Cp) at different faces of the models are carried out for different wind occurrence angles employing Computational Fluid Dynamics method of simulated wind flow. Again, Fast Fourier Transform (FFT) fitted expressions as the sine and cosine function of WAA are proposed for attaining mean wind pressure coefficient on the building faces. The accuracy of the Fourier series expansions is justified by presenting histograms of sum square error (SSE), R2 value and root mean square error (RMSE). The results are also compared by training Artificial Neural Networks (ANN). Training is continued till Regression (R) values are more than 0.99 and Mean Squared Error (MSE) tends to 0, ensuring a close relationship among the outputs and targets. The face-wise value of (Cp) obtained using all three methods, are plotted. The error histograms of the ANN models show that the fitting data errors are spread within a reasonably good range. It is observed that the deviation in the result is not more than 5% in any case. Finally, the ANN predictions are presented for nine parametric models to cover a wide range of possible cross-shaped buildings.


2011 ◽  
Vol 27 (3) ◽  
pp. 939-946 ◽  
Author(s):  
Rakesh K. Goel

This paper compares base shears computed from floor accelerations (inertial base shear) and column shears (structural base shear) for two mid-rise, multistory buildings due to a suite of 30 earthquake ground motions. The presented results demonstrate that the inertial base shear exceeds the structural base shear in the median by 10% to 20% and may exceed the structural base shear by as much as 70% for individual ground motions. Therefore, it is concluded that the inertial base shear computed from strong motion records should be used with caution to estimate the structural base shear.


2013 ◽  
Vol 40 (7) ◽  
pp. 655-662
Author(s):  
George K. Georgoussis

Building structures of low or medium height are usually designed with a pseudostatic approach using a base shear much lower than that predicted from an elastic spectrum. Given this shear force, the objective of this paper is to evaluate the effect of the element strength assignment (as determined by several building codes) on the torsional response of inelastic single-storey eccentric structures and to provide guidelines for minimizing this structural behaviour. It is demonstrated that the expected torque about the centre of mass (CM) may be, with equal probability, positive (counterclockwise) or negative (clockwise). This result means that the torsional strength should also be provided in equal terms in both rotational directions, and therefore the base shear and torque (BST) surface of a given system must be symmetrical (or approximately symmetrical). In stiffness-eccentric systems, appropriate BST surfaces may be obtained when a structural design is based on a pair of design eccentricities in a symmetrical order about CM, and this is shown in representative single-storey building models under characteristic ground motions.


Buildings ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 90
Author(s):  
Francesco Cascone ◽  
Diana Faiella ◽  
Valentina Tomei ◽  
Elena Mele

An innovative generative design strategy, based on shape grammar, is proposed for the minimum-weight design of diagrid tall buildings. By considering the building as a three-dimensional vertical cantilever beam with a tubular section under horizontal load, it is evident that bending and shear stiffness demands vary along the width and elevation of the building. Further, while the structural design of tall buildings is usually governed by stiffness, the predominant design criterion for diagrids could be the local strength demand, especially for low slenderness values, thanks to the inherent rigidity of the triangular pattern. Starting from these considerations, in this paper, a generative design strategy is proposed, able to find diagrid patterns that accommodate the differentiated stiffness demand along width/elevation and satisfy the predominant design criterion, stiffness or strength. The design strategy is applied to tall building models characterised by different slenderness values. The comparison to diagrid patterns analysed in previous literature works in terms of structural weight and performance parameters highlights the effectiveness of the design strategy and the efficiency of the generated patterns.


Author(s):  
Dongqi Jiang ◽  
Shanquan Liu ◽  
Tao Chen ◽  
Gang Bi

<p>Reinforced concrete – steel plate composite shear walls (RCSPSW) have attracted great interests in the construction of tall buildings. From the perspective of life-cycle maintenance, the failure mode recognition is critical in determining the post-earthquake recovery strategies. This paper presents a comprehensive study on a wide range of existing experimental tests and develops a unique library of 17 parameters that affects RCSPSW’s failure modes. A total of 127 specimens are compiled and three types of failure modes are considered: flexure, shear and flexure-shear failure modes. Various machine learning (ML) techniques such as decision trees, random forests (RF), <i>K</i>-nearest neighbours and artificial neural network (ANN) are adopted to identify the failure mode of RCSPSW. RF and ANN algorithm show superior performance as compared to other ML approaches. In Particular, ANN model with one hidden layer and 10 neurons is sufficient for failure mode recognition of RCSPSW.</p>


1990 ◽  
Vol 6 (4) ◽  
pp. 641-655 ◽  
Author(s):  
Gregory L. Fenves ◽  
Giorgio Serino

An evaluation of the response of a fourteen story reinforced concrete building to the 1 October 1987 Whittier earthquake and 4 October 1987 aftershock shows significant effects of soil-structure interaction. A mathematical model of the building-foundation-soil system provides response quantities not directly available from the records. The model is calibrated using the dynamic properties of the building as determined from the processed strong motion records. Soil-structure interaction reduces the base shear force in the longitudinal direction of the building compared with the typical assumption in which interaction is neglected. The reduction in base shear for this building and earthquake is approximately represented by proposed building code provisions for soil-structure interaction.


2019 ◽  
Vol 8 (4) ◽  
pp. 3633-3637

Precast concrete structures are widely used in construction. It consists of prefabricated elements casted in industry and connected to each other to form a homogeneous structure. Connections function is to transfer moments and axial forces. Many engineers assume precast connection as pinned, but in reality, they are semi-rigid connections that transfer forces to other members. Lack of design and detailing of connection leads to improper behaviour of the structure, which then leads to the collapse of the building. Past earthquake studies show that many precast buildings performed poorly, and the main reasons were connections. This paper mainly focuses on understanding the seismic behaviour of mid-rise i.e seven-storey precast reinforced concrete buildings with various beam-column joints i.e rigid, semi-rigid, pinned and column-base supports i.e, fixed and hinged supports. Building is modelled and analyzed using ETABS v17 software. Rotational stiffness of precast billet connection is adopted for modelling of semi-rigid beam-column connections. Response spectrum and modal analysis are carried out. Results of displacements, storey drift, storey shear, storey stiffness, base shear, time periods and first mode shapes of models are discussed. It is observed, precast reinforced concrete building models with semi rigid connection performs better than building models with pinned connections and building models with fixed supports reduces the structural response to a great extent.


1965 ◽  
Vol 87 (1) ◽  
pp. 117-130 ◽  
Author(s):  
R. D. Zerkle ◽  
J. Edward Sunderland

The transient, one-dimensional temperature distribution is determined for a slab, insulated on one face, and subjected to thermal radiation at the other face. The slab is initially at a uniform temperature and is assumed to be homogeneous, isotropic, and opaque; the physical properties are assumed to be independent of temperature. Transient temperature distributions for both heating and cooling situations are obtained by means of a thermal-electrical analog computer. A diode limiter circuit is used to simulate the nonlinear radiant heat flux. The transient temperature distributions are presented in a dimensionless, graphical form for a wide range of variables. Approximate analytical solutions are also given which complement and extend the solution charts over ranges of parameters not covered in the charts.


1973 ◽  
Vol 63 (3) ◽  
pp. 1025-1039
Author(s):  
Bruce M. Douglas ◽  
Thomas E. Trabert

abstract The coupled bending and torsional vibrations of a relatively symmetric 22-story reinforced concrete building in Reno, Nevada are studied. Analytical results are compared with observations obtained during the nuclear explosion FAULTLESS and to ambient vibration data. The fundamental periods of vibration observed during FAULTLESS were (TNS = 1.42, TEW = 1.81, TTORSION = 1.12 sec), and the calculated periods were (TNS = 2.14, TEW = 2.07, TTORSION = 1.90 sec). It was estimated that between 25 and 45 per cent of the total available nonstructural stiffness was required to explain the differences in the observed and calculated fundamental periods. Each floor diaphragm in the system was allowed three degrees of freedom-two translations and a rotation. It was found that coupled torsional motions can influence the response of structural elements near the periphery of the structure. Strong-motion structural response calculations comparing the simultaneous use of both components of horizontal ground motion to a single component analysis showed that the simultaneous application of both components of ground motion can significantly alter the response of lateral load-carrying elements. Differences of the order of 45 per cent were observed in the frames near the ends of the structure. Also, it was shown that the overall response of tall buildings is sensitive not only to the choice of input ground motion but also to the orientation of the structure with respect to the seismic waves.