scholarly journals First Clinical Results of Modular Intraocular Lens Implantation

2021 ◽  
Vol 18 (2) ◽  
pp. 240-244
Author(s):  
E. N. Batkov ◽  
T. F. Artemyeva ◽  
N. P. Pashtayev ◽  
N. A. Pozdeyeva

Introduction. Recent population studies reveal steady growth in intraocular lens (IOL) exchanges including those for refractive and other optical reasons. To lower complication risks related to IOL exchange, we introduced a modular IOL model with replaceable optical part.Purpose: preliminary analysis of modular IOL implantation clinical results.Patients and methods. From August 2018 to February 2020, five patients as part of their surgical treatment for various forms of cataract received newly designed modular IOLs. The modular IOL is composed of two separate parts — haptic and optic, manufactured from the same elastic acrylic material with hydrophobic properties. The haptic includes a closed ring and a pair of open equally distant loops in a unified design. The haptic ring with projections serves as a base for optical disk. The current study evaluated characteristics of the IOL implantation and assembly process, as well as possible development of intra- and early postoperative complications.Results. First implantations of the modular IOL accomplished using standard surgical instrumentation and disposables passed without complications. We did not observe scratches, breaks or any other mechanical damage to neither haptic, nor optical parts. During simultaneous implantation, optical disks fixated in haptic rings preserved their due positioning after transiting through slender injector channel. There were no specific, modular-IOL related complications in the early postoperative period. The optical disk maintained correct location, delimited by fixation leaflets of the haptic ring.Conclusion. Early results for clinical application of the novel modular IOL demonstrated feasibility of its safe implantation in disassembled and preassembled modes. 

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Soa Kim ◽  
Jee Taek Kim

AbstractWe describe a simply modified intrascleral fixation using round flange (SMURF) technique and report the clinical outcomes of the surgery. Forty-one eyes of 41 consecutive patients, with intraocular lens (IOL) dislocation, crystalline lens subluxation, and zonular weakness, who underwent surgery using the SMURF technique were included. The modified technique included the use of a conventional 27-gauge needle, a non-bent needle, oblique sclerotomy, direct threading of the leading haptic, and simple placement of the following haptic. IOLs were successfully placed and showed good centring. There were no cases of wound leakage or hypotony during the early postoperative period. Postoperative complications included vitreous haemorrhage in one eye (2.4%), intraocular pressure elevation in one eye (2.4%), and iris capture in six eyes (14.6%). There were no cases of postoperative retinal detachment, cystoid macular oedema, endophthalmitis, or IOL dislocation during the follow-up period. We proposed a few modifications in the intrascleral flanged technique for IOL fixation. The modified technique is a simple, easy, and minimally invasive procedure for successful IOL intrascleral fixation.


2016 ◽  
Vol 2016 ◽  
pp. 1-5 ◽  
Author(s):  
A-Yong Yu ◽  
Hua Guo ◽  
Qin-Mei Wang ◽  
Fang-Jun Bao ◽  
Jing-Hai Huang

Objective. To investigate mydriatic effect of intracamerally injected epinephrine hydrochloride during phacoemulsification and intraocular lens (IOL) implantation.Methods. Eighteen cataract patients for bilateral phacoemulsification were enrolled. To dilate pupil, one eye was randomly selected to receive intracamerally 1 mL epinephrine hydrochloride 0.001% for 1 minute after corneal incision (intracameral group), and the contralateral eye received 3 drops of compound tropicamide 0.5% and phenylephrine 0.5% at 5-minute intervals 30 minutes before surgery (topical group). Pupil diameters were measured before corneal incision, before ophthalmic viscoelastic device (OVD) injection, after OVD injection, before IOL implantation, and at the end of surgery.Results. At each time point, the mean pupil diameter in the intracameral group was2.20±0.08,5.09±0.20,6.76±0.19,6.48±0.18, and5.97±0.24 mm, respectively, and in the topical group it was7.98±0.15,7.98±0.15,8.53±0.14,8.27±0.16, and7.93±0.20 mm, respectively. The topical group consistently had larger mydriatic effects than the intracameral group (P<0.05). The onset of mydriatic effect was rapid in the intracameral group. There was no difference in surgical performance or other parameters between groups.Conclusions. Intracameral epinephrine hydrochloride appears to be an alternative to the mydriatic modalities for phacoemulsification and IOL implantation. In comparison with topical mydriatics, intracameral epinephrine hydrochloride offers easier preoperative preparation, more rapid pupil dilation, and comparable surgical performance.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Ayoung Choi ◽  
Hyunggoo Kwon ◽  
Sohee Jeon

AbstractThe accuracy of intraocular lens (IOL) calculations is suboptimal for long or short eyes, which results in a low visual quality after multifocal IOL implantation. The purpose of the present study is to evaluate the accuracy of IOL formulas (Barrett Universal II, SRK/T, Holladay 1, Hoffer Q, and Haigis) for the Acrysof IQ Panoptix TFNT IOL (Alcon Laboratories, Inc, Fort Worth, Texas, United States) implantation based on the axial length (AXL) from a large cohort of 2018 cases and identify the factors that are associated with a high mean absolute error (MAE). The Barrett Universal II showed the lowest MAE in the normal AXL group (0.30 ± 0.23), whereas the Holladay 1 and Hoffer Q showed the lowest MAE in the short AXL group (0.32 ± 0.22 D and 0.32 ± 0.21 D, respectively). The Haigis showed the lowest MAE in the long AXL group (0.24 ± 0.19 D). The Barrett Universal II did not perform well in short AXL eyes with higher astigmatism (P = 0.013), wider white-to-white (WTW; P < 0.001), and shorter AXL (P = 0.016). Study results suggest that the Barrett Universal II performed best for the TFNT IOL in the overall study population, except for the eyes with short AXL, particularly when the eyes had higher astigmatism, wider WTW, and shorter AXL.


2018 ◽  
Vol 2018 ◽  
pp. 1-8 ◽  
Author(s):  
Dilek Yaşa ◽  
Ufuk Ürdem ◽  
Alper Ağca ◽  
Yusuf Yildirim ◽  
Burçin Kepez Yildiz ◽  
...  

Purpose. To report clinical results of a foldable, hydrophilic acrylic, single-piece, injectable, posterior chamber phakic intraocular lens (pIOL).Material and Methods. Medical records of patients who underwent posterior chamber phakic IOL (Eyecryl Phakic IOL, Biotech Vision Care, Ahmedabad, India) implantation for surgical correction of myopia were retrospectively reviewed. Only patients with at least a one-year follow-up were included. Manifest refraction, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), endothelial cell density (ECD), and pIOL vault were analyzed at 1, 3, 6, and 12 months after surgery. Complications observed during and after surgery were also recorded.Results. The study included 58 eyes of 29 patients. Mean patient age was 32 ± 7 years. Spherical equivalent of manifest refraction was −13.41 ± 3.23 D preoperatively and −0.44 ± 0.55 D postoperatively. Preoperative CDVA was 0.29 ± 0.71 logMAR. Postoperative UDVA and CDVA were 0.21 ± 0.66 and 0.15 ± 0.69 logMAR, respectively, at the 12-month visit. At the 12-month visit, the efficacy index was 1.20 and the safety index was 1.39. Mean ECD was 2713 ± 339 cells/mm2at the preoperative visit and 2608 ± 362 cells/mm2at the 12-month visit (3.9% loss,p<0.001). ECD loss from 3 months to 12 months was not statistically significant. No significant cataract formation, significant endothelial cell loss, glaucoma, uveitis, or any other vision-threatening complication was observed.Conclusion. Based on postoperative experience, we have found that Eyecryl Phakic IOL is safe and effective for treating high myopia.


2017 ◽  
Vol 38 (5) ◽  
pp. 1977-1983
Author(s):  
Wojciech Lubiński ◽  
Marta Kirkiewicz ◽  
Karolina Podborączyńska-Jodko

2020 ◽  
Author(s):  
Da young Shin ◽  
Ho Sik Hwang ◽  
Hyun Seung Kim ◽  
Man Soo Kim ◽  
Eun Chul Kim

Abstract Background: To analyze and compare the clinical results of toric intraocular lens (IOL) and monofocal IOL implantation when the target refraction value is determined -3 diopter (D) in cataract patients with corneal astigmatism >1.5 diopters (D).Methods: We performed a retrospective chart review for patients with corneal astigmatism >1.5D who underwent cataract surgery and their target refraction is determined -3D. 100 eyes (100 patients; monofocal IOL, 60; toric IOL, 40) were enrolled in the current study. Near and distant uncorrected visual acuity (UCVA), corrected VA, spherical equivalent and refractive, corneal astigmatism were evaluated before and after surgery.Results: The near UCVA of the toric IOL group (0.26±0.33) after cataract surgery was significantly better than that of the monofocal IOL group (0.48±0.32) (p=0.030). The distant UCVA of the toric IOL group (0.38 ± 0.14) was also significantly better than that of the monofocal IOL group (0.55 ± 0.22) (p = 0.026). There were no significant intergroup differences in postoperative best-corrected visual acuity (p = 0.710) and mean spherical equivalent (p = 0.465). In the toric IOL group, postoperative refractive astigmatism was -0.80 ± 0.46D and postoperative corneal astigmatism was -1.50 ± 0.62D, whereas the corresponding values in the monofocal IOL group were -1.65 ± 0.77D and -1.45 ± 0.64D; residual refractive astigmatism was significantly lower with toric IOL implantation compared with monofocal IOL implantation (p = 0.001). Conclusions: When myopic refraction such as -3D was determined as the target power in patients with corneal astigmatism, toric IOL implantation led to excellent improvement in both near and distant UCVA.


2020 ◽  
Vol 7 (12) ◽  
pp. 189-198
Author(s):  
Zeynep Başağaoğlu Demirekin ◽  
Yavuz Findik ◽  
S. Süha Turkaslan ◽  
Timuçin Baykul ◽  
Merve Erken

Introduction: The interpretation of clinical results of dental implant supported prosthesis treatment is very crucial to be able to make a comparison between different implant systems and treatment options and furthermore to benefit the experiences of the other clinicians. However, the clinical outcomes of these studies should be reported in an objective way and be independent from the system used and also be prepared in accordance with certain criteria and standards that have been accepted scientifically world-wide for being reliable and describing long-term results. Aim: Three-hundred and eighty-two consecutive NTA implants were performed on ninety-nine patients. The implants used in 2016 and the constructed restorations were retrospectively analyzed. In addition, the effect of the experience of clinician was evaluated related with the success of the implant therapy. Materials and Method: This retrospective study was conducted in the Department of Prosthodontics Süleyman Demirel University. Three-hundred and eighty-two consecutive NTA implants were performed on ninety-nine patients. The implants used in 2016 and the constructed restorations were retrospectively analyzed. Results: The implants were followed for at least 2 years. In total, 239 implants were inserted. It was found in 143 mandibles. Prosthetic restorations were determined to be partial prosthetics (219), single crown (81) and overdenture prosthetics (64). During the evaluation period, 6 implants failed before prosthetic treatment, ten decementations, six retentive screw loosening and five porcelain chipping were detected. Discussion and Conclusions: The early results of our study are consistent with the results of other studies. However, long-term follow-up is required for more accurate assessments.


2020 ◽  
Author(s):  
xinqi ma ◽  
ming zhou ◽  
jiajie wen ◽  
yujia ouyang ◽  
chongde long

Abstract Background: Intraocular lens (IOL) dislocation is a rare but serious postoperative complication of intraocular lens implantation, so far, there is no report describing late intraocular lens dislocation caused by a deformed haptic piercing through the iris. Case report: A 29-year-old male developed IOL dislocation one and a half years after IOL implantation in his right eye. The eye examination showed that haptic pierced the iris at 10 o'clock in his right eye, according to intraoperative exploration, the haptic was deformed and became less elastic, the patient underwent the surgery of IOL reposition for various factors, but finally did not achieve a satisfactory outcome. Conclusion: Late IOL dislocation followed by haptic deformation is difficult to detect unless there are serious complications. When the position of IOL haptics is not in a plane with its optical surface, it should be highly vigilant that the function of the haptics may be abnormal. IOL replacement should be performed as soon as possible for the IOL dislocation caused by the loss of haptic tension.