scholarly journals Simultaneous Determination of Aspirin and Rosuvastatin Calcium in Capsules by Using RP-HPLC Coupled with Photo Diode Array Detection

Author(s):  
Ankita Panchal ◽  
Gaurav Sanghvi ◽  
Ashish Vachhani ◽  
Navin Sheth ◽  
Devendra Vaishnav

A simple, sensitive, specific, and cost effective method for simultaneous determination of Aspirin and Rosuvastatin calcium was developed and validated in single dosage formulation. The sample solution of ASP and RSTC was prepared using methanol as a solvent. Separation of ASP and RSTC was achieved with a mobile phase consisting of 20 mM KH2PO4 : Methanol (30:70 v/v) at a flow rate of 1.0 ml/min. Separations were performed on Merck hibar 250-4.6 RP18 (5 µm) column (150 mm X 3.0 mm), using a Shimadzu Prominence HPLC system equipped with a Shimadzu SPD-20A detector, Rhenodyne 7725i injector with 20 μL loop, LC-20 AD pump, CBM-20 Alite controller and LC Solution software. Retention times of ASP and RSTC were 3.747 and 5.969 minutes respectively. Absolute recovery of ASP and RSTC was 100.3 and 100.03 % respectively. The lower limit of quantification (LLOQ) of ASP and RSTC was 0.3097 and 0.1063 ppm and lower limit of detection (LLOD) of ASP and RSTC was 0.01535 and 0.01358 ppm respectively. Linearity was established for the range of concentrations 15.00-90.0 μg/ml and 2.0-12.0 μg/ml for ASP and RSTC respectively with the coefficient of determination (R2) of 0.994 and 0.999 for both the compounds. The inter- and intra-day precision in the measurement of ASP quality control (QC) sample 75 μg/ml, were in the range 0.1-0.2 % relative standard deviation (R.S.D.) and 0.2-0.3 % R.S.D., respectively. The inter- and intra-day precision in the measurement of RST quality control (QC) sample 10 μg/ml, were in the range 0.1-0.2 % R.S.D., and 0.0-0.3 % R.S.D., respectively. The developed method would be applicable for routine quality control of ASP And RSTC in bulk as well as in pharmaceutical formulations

2013 ◽  
Vol 2013 ◽  
pp. 1-5 ◽  
Author(s):  
Garima Balwani ◽  
Emil Joseph ◽  
Satish Reddi ◽  
Vibhu Nagpal ◽  
Ranendra N. Saha

A new, simple, rapid, sensitive, accurate, and affordable spectrofluorimetric method was developed and validated for the estimation of ganciclovir in bulk as well as in marketed formulations. The method was based on measuring the native fluorescence of ganciclovir in 0.2 M hydrochloric acid buffer of pH 1.2 at 374 nm after excitation at 257 nm. The calibration graph was found to be rectilinear in the concentration range of 0.25–2.00 μg mL−1. The limit of quantification and limit of detection were found to be 0.029 μg mL−1and 0.010μg mL−1, respectively. The method was fully validated for various parameters according to ICH guidelines. The results demonstrated that the procedure is accurate, precise, and reproducible (relative standard deviation <2%) and can be successfully applied for the determination of ganciclovir in its commercial capsules with average percentage recovery of 101.31 ± 0.90.


2018 ◽  
Vol 15 (2) ◽  
pp. 6186-6198
Author(s):  
Abdul Aziz Ramadan ◽  
Souad Zeino

A simple, direct and accurate spectrophotometric method has been developed for the determination of Glimepiride (GLM) in pure and pharmaceutical formulations by complex formation with bromocresol purple (BCP). The method involves the formation of a yellow ion-pair complex between BCP with glimepiride at pH<3,8; after reacting GLM with Na2CO3 to give C24H33N4H+O5NaS which is extracted by chloroform. The formed complex [GLM]:[ BCP] was measured at lmax 418 nm against the reagent blank prepared in the same manner. Variables were studied in order to optimize the reaction conditions. Molar absorptivity (e) for complex was  20600  L.mol-1.cm-1. Beer’s law was obeyed in the concentration range of  1.226 – 46.608   mg.mL-1 in present of 5.0x10-4 mol/l of BCP with good correlation coefficient (R2= 0.9997). The relative standard deviation did not exceed 3.6%. The limit of detection (LOD) and the limit of quantification (LOQ) were 0.15 and 0.46 mg.mL-1, respectively. The proposed method was validated for specificity, linearity, precision and accuracy, repeatability, sensitivity (LOD and LOQ)  and robustness. The developed method is applicable for the determination of GLM in  pure and different dosage forms with average assay of 98.8 to 102.0% and the results are in good agreement with those obtained by the  RP-HPLC reference method.  


Toxins ◽  
2019 ◽  
Vol 11 (2) ◽  
pp. 87 ◽  
Author(s):  
Wenbo Guo ◽  
Kai Fan ◽  
Dongxia Nie ◽  
Jiajia Meng ◽  
Qingwen Huang ◽  
...  

A simple and reliable analytical method for the simultaneous determination of alternariol (AOH), altenuene (ALT), tentoxin (TEN), altenusin (ALS), tenuazonic acid (TeA), and alternariol monomethyl ether (AME) in grapes was developed by ultra-high-performance liquid chromatography–tandem mass spectrometry (UHPLC-MS/MS). A modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) procedure with the extraction by acetonitrile and purification by sodium chloride (0.5 g) and anhydrous magnesium sulfate (0.5 g) was established to recover the six Alternaria toxins. After validation by determining the linearity (R2 > 0.99), recovery (77.8–101.6%), sensitivity (limit of detection in the range of 0.03–0.21 μg kg−1, and limit of quantification in the range of 0.09–0.48 μg kg−1), and precision (relative standard deviation (RSD) ≤ 12.9%), the analytical method was successfully applied to reveal the contamination state of Alternaria toxins in grapes. Among 56 grape samples, 40 (incidence of 71.4%) were contaminated with Alternaria toxins. TEN was the most frequently found mycotoxin (37.5%), with a concentration range of 0.10–1.64 μg kg−1, followed by TeA (28.6%) and AOH (26.8%). ALT (10.7%), AME (3.6%), and ALS (5.4%) were also detected in some samples. To the best of our knowledge, this is the first report about the Alternaria toxins contamination in grapes in China.


2009 ◽  
Vol 6 (4) ◽  
pp. 1233-1239 ◽  
Author(s):  
J. Saminathan ◽  
A. S. Sankar ◽  
K. Anandakumar ◽  
T. Vetrichelvan

A simple and cost effective spectrophotometric method is described for the determination of fluvastatin sodium in pure form and in pharmaceutical formulations. When the drug reacts with sodium hydroxide shows absorption maximum at 304 nm and obeys beer's law in the concentration range 5-25 µg mL-1. The absorbance was found to increase linearly with increasing concentration of FVS, which is corroborated by the calculated correlation coefficient value of 0.9999 (n=5). The apparent molar absorptivity and sandell sensitivity were 1.1905×104and 0.0368844 µg cm-2cm respectively. The slope and intercept of the equation of the regression line are 0.027112 and 0.003539 respectively. The limit of detection and limit of quantification was found to be 0.0811 µg mL-1& 0.2460 µg mL-1. The validity of the described procedure was assessed. Statistical analysis of the result has been carried out revealing high accuracy and good precision. The proposed method was successfully applied to the determination of FVS in pharmaceutical formulations without any interference from common excipients. The relative standard deviations were ≤ 0.937%, with recoveries of 98.60% -101.70%.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Indhu Priya Mabbu ◽  
G. Sumathi ◽  
N. Devanna

Abstract Background The aim of the present method is to develop and validate a specific, sensitive, precise, and accurate liquid chromatography-mass spectrometry (LC-MS) method for the estimation of the phenyl vinyl sulfone in the eletriptan hydrobromide. The effective separation of the phenyl vinyl sulfone was achieved by the Symmetry C18 (50 × 4.6 mm, 3.5 μm) column and a mobile phase composition of 0.1%v/v ammonia buffer to methanol (5:95 v/v), using 0.45 ml/min flow rate and 20 μl of injection volume, with methanol used as diluent. The phenyl vinyl sulfone was monitored on atomic pressure chemical ionization mode mass spectrometer with positive polarity mode. Results The retention time of phenyl vinyl sulfone was found at 2.13 min. The limit of detection (LOD) and limit of quantification (LOQ) were observed at 1.43 ppm and 4.77 ppm concentration respectively; the linear range was found in the concentration ranges from 4.77 to 27.00 ppm with regression coefficient of 0.9990 and accuracy in the range of 97.50–102.10%. The percentage relative standard deviation (% RSD) for six replicates said to be injections were less than 10%. Conclusion The proposed method was validated successfully as per ICH guidelines. Hence, this is employed for the determination of phenyl vinyl sulfone in the eletriptan hydrobromide.


2013 ◽  
Vol 634-638 ◽  
pp. 1586-1590
Author(s):  
Su Fang Wang ◽  
Shou Jie Zhang ◽  
Chun Hong Dong ◽  
Guo Qing Wang ◽  
Jun Feng Guo ◽  
...  

A method for simultaneous determination of residuals of four herbicides and pesticides, simazine, carboxin, diflubenzuron and rotenone, in Chinese green tea was developed. In the proposed method, the tea powder was placed in a centrifuge tube with a plug, extracted in saturated aqueous sodium chloride solution and acetonitrile, agitated using vortex oscillator, and then centrifuged 5 min at 4000 rpm. The supernatant solution was purified by primary secondary amine (PSA) sorbent, C18 power, and graphitized carbon black powder, respectively. Then the purified extracts were dissolved with acetonitrile:0.1% formic acid aqueous solution (40:60, V/V) and agitated, filtered using a syringe with 0.22 μm nylon filter prior to UPLC-MS/MS analysis. The UPLC analysis was performed on an ACQUITY UPLC® HSS T3 column (2.1 mm×100 mm, 1.8 µm), using acetonitrile-0.1% formic acid as mobile phase with the flow rate as 0.3 mL•min-1. Injection volume was 10 µL. Positive ionization mode was applied, and the ions were monitored in the multiple reaction monitoring (MRM) mode with curtain gas 0.069 MPa, collision gas 0.052 MPa, ESI ion spray voltage 5000 V, temperature 550 °C, nebulizer gas 0.24 MPa, and turbo gas 0.28 MPa. The limit of detection (LOD) and limit of quantitation (LOQ) of the proposed method are 1 μg•kg-1and 5 μg•kg-1, respectively. The average recoveries of the four pesticides at 10, 20, and 50 µg•kg-1spiking levels range from 77.4% to 95.3%. TheSupersSuperscript textcript textrelative standard deviation (RSD) (n=6) range form 11.83% to 4.52%.


Molecules ◽  
2021 ◽  
Vol 26 (7) ◽  
pp. 1837
Author(s):  
Harischandra Naik Rathod ◽  
Bheemanna Mallappa ◽  
Pallavi Malenahalli Sidramappa ◽  
Chandra Sekhara Reddy Vennapusa ◽  
Pavankumar Kamin ◽  
...  

A quick, sensitive, and reproducible analytical method for the determination of 77 multiclass pesticides and their metabolites in Capsicum and tomato by gas and liquid chromatography tandem mass spectrometry was standardized and validated. The limit of detection of 0.19 to 10.91 and limit of quantification of 0.63 to 36.34 µg·kg−1 for Capsicum and 0.10 to 9.55 µg·kg−1 (LOD) and 0.35 to 33.43 µg·kg−1 (LOQ) for tomato. The method involves extraction of sample with acetonitrile, purification by dispersive solid phase extraction using primary secondary amine and graphitized carbon black. The recoveries of all pesticides were in the range of 75 to 110% with a relative standard deviation of less than 20%. Similarly, the method precision was evaluated interms of repeatability (RSDr) and reproducibility (RSDwR) by spiking of mixed pesticides standards at 100 µg·kg−1 recorded anRSD of less than 20%. The matrix effect was acceptable and no significant variation was observed in both the matrices except for few pesticides. The estimated measurement uncertainty found acceptable for all the pesticides. This method found suitable for analysis of vegetable samples drawn from market and farm gates.


2017 ◽  
Vol 9 (5) ◽  
pp. 102
Author(s):  
Sukhjinder Kaur ◽  
Taranjit Kaur ◽  
Gurdeep Kaur ◽  
Shivani Verma

Objective: The aim of the present work was to develop a simple, rapid, accurate and economical UV-visible spectrophotometric method for the determination of hydroquinone (HQ) in its pure form, marketed formulation as well as in the prepared nanostructured lipid carrier (NLC) systems and to validate the developed method.Methods: HQ was estimated at UV maxima of 289.6 nm in pH 5.5 phosphate buffer using UV-Visible double beam spectrophotometer. Following the guidelines of the International Conference on Harmonization (ICH), the method was validated for various analytical parameters like linearity, precision, and accuracy robustness, ruggedness, limit of detection, quantification limit, and formulation analysis.Results: The obtained results of the analysis were validated statistically. Recovery studies were performed to confirm the accuracy of the proposed method. In the developed method, linearity over the concentration range of 5-40 μg/ml of HQ was observed with the correlation coefficient of 0.998 and found in good agreement with Beer Lambert’s law. The precision (intra-day and inter-day) of the method was found within official RCD limits (RSD<2%).Conclusion: The sensitivity of the method was assessed by determining the limit of detection and limit of quantification. It could be concluded from the results obtained that the purposed method for estimation of HQ in pure form, in the marketed ointment and in the prepared NLC-formulation was simple, rapid, accurate, precise and economical. It can be used successfully in the quality control of pharmaceutical formulations and for the routine laboratory analysis.


2003 ◽  
Vol 68 (8-9) ◽  
pp. 691-698 ◽  
Author(s):  
Milena Jelikic-Stankov ◽  
Predrag Djurdjevic ◽  
Dejan Stankov

In this work a new enzymatic method for the determination of uric acid in human serum has been developed. The method is based on the oxidative coupling reaction between the N-methyl-N-(4-aminophenyl)-3-methoxyaniline (NCP) reagent and the hydrogen ? donor reagent N-ethyl-N-(2-hydroxy-3-sulfopropyl)-3-methylaniline (TOOS), in the system involving three enzymes: uricase, peroxidase and ascorbate oxidase. Using this method uric acid could be determined in concentrations up to 1.428 mmol/L, with a relative standard deviation of up to 1.8 %. The effect of the medium pH and the NCP concentration on the linearity of the chromogen absorbance versus the uric acid concentration curve was investigated. The influence of the uricase activity on the maximum rate of uric acid oxidation was also examined. The use of the NCP reagent demonstrated a more precise and more sensitive determination of the uric acid compared to the determination with 4-aminoantipyrine (4-AA) as the coupling regent. The sensitivity of the method determined from the calibration curve was 0.71 absorbance units per mmol/L of uric acid; the limit of detection was LOD = 0.0035 mmol/L and the limit of quantification was LOQ = 0.015 mmol/L of uric acid.


2021 ◽  
Vol 10 (1) ◽  
pp. 20-28
Author(s):  
Ivana Savić-Gajić ◽  
Ivan Savić ◽  
Predrag Sibinović ◽  
Valentina Marinković

In this study, the modified stability-indicating RP-HPLC method was validated for quantitative analysis of amlodipine besylate in the presence of its impurity D (3-ethyl 5-methyl 2-[(2-aminoethoxy)methyl]-4-(2-chlorophenyl)-6-methylpyridine-3,5-dicarboxylate). The method was applied for the determination of an analyte in the tablets and irradiated samples packed in the primary packaging (Alu/PVC/PVDC blister packaging). The efficient chromatographic separation was achieved using a ZORBAX Eclipse XDB-C18 column (4.6×250 mm, 5 mm) with isocratic elution of mobile phase which consisted of acetonitrile:methanol:triethylamine solution (15:35:50, v/v/v) (pH 3.0). The flow rate of the mobile phase was 1 mL min-1, while the detection of amlodipine besylate was carried out at 273 nm. Amlodipine besylate and its impurity D were identified at the retention times of 16.529 min and 2.575 min, respectively. The linearity of the method with the coefficient of determination of 0.999 was confirmed in the concentration range of 10 - 75 µg mL-1 for amlodipine besylate. The limit of detection was 0.2 µg mL-1, while the limit of quantification was 0.66 µg mL-1. After UV and Vis radiation of the tablets packed in the primary packaging, the content of amlodipine besylate was reduced by 22.38% and 19.89%, respectively. The presence of new degradation products was not detected under the given chromatographic conditions. The photodegradation of amlodipine besylate followed pseudo-first-order kinetics. Based on the half-life of amlodipine besylate (38.4 days for UV radiation and 43.3 days for Vis radiation), it was concluded that amlodipine besylate in the tablets has satisfactory photostability after its packing in the Alu/PVC/PVDC blister packaging.


Sign in / Sign up

Export Citation Format

Share Document