scholarly journals Determination of uric acid in human serum by an enzymatic method using N-methyl-N-(4-aminophenyl)-3-methoxyaniline reagent

2003 ◽  
Vol 68 (8-9) ◽  
pp. 691-698 ◽  
Author(s):  
Milena Jelikic-Stankov ◽  
Predrag Djurdjevic ◽  
Dejan Stankov

In this work a new enzymatic method for the determination of uric acid in human serum has been developed. The method is based on the oxidative coupling reaction between the N-methyl-N-(4-aminophenyl)-3-methoxyaniline (NCP) reagent and the hydrogen ? donor reagent N-ethyl-N-(2-hydroxy-3-sulfopropyl)-3-methylaniline (TOOS), in the system involving three enzymes: uricase, peroxidase and ascorbate oxidase. Using this method uric acid could be determined in concentrations up to 1.428 mmol/L, with a relative standard deviation of up to 1.8 %. The effect of the medium pH and the NCP concentration on the linearity of the chromogen absorbance versus the uric acid concentration curve was investigated. The influence of the uricase activity on the maximum rate of uric acid oxidation was also examined. The use of the NCP reagent demonstrated a more precise and more sensitive determination of the uric acid compared to the determination with 4-aminoantipyrine (4-AA) as the coupling regent. The sensitivity of the method determined from the calibration curve was 0.71 absorbance units per mmol/L of uric acid; the limit of detection was LOD = 0.0035 mmol/L and the limit of quantification was LOQ = 0.015 mmol/L of uric acid.

2000 ◽  
Vol 65 (7) ◽  
pp. 473-479
Author(s):  
Milena Jelikic-Stankov ◽  
Dejan Stankov ◽  
Snezana Paunovic

A sensitive and specific enzymatic method has been developed for the determination of the total and free cholesterol in human serum based on the application of the newly-synthesized N-ethyl-N-(2-hydroxy-3-sulfopropyl)-3,5-dimethoxyaniline, (DAOS) Trinder's reagent. Using the proposed method, cholesterol could be determined in the concentration range of 0.15 mmol/L with a relative standard deviation of up to 1.1%. In order to find the optimal experimental conditions for the application of the DAOS reagent, the influence of its concentration on the linearity of the method, the influence of pH, as well as the influence of the activities of cholesterolesterase and cholesteroloxidase were examined. The obtained results of the determination of the total and free cholesterol were compared to the results obtained by the application of the most frequently employed enzymatic method in clinical practice, based on phenol as a reagent. The sensitivity of the method was 0.070 A/mmol/L, the limit of detection DL=0.03 mmol/L and the limit of quantification QL=0.09 mmol/L of cholesterol.


2020 ◽  
Vol 16 ◽  
Author(s):  
Nadereh Rahbar ◽  
Fatemeh Ahmadi ◽  
Zahra Ramezani ◽  
Masoumeh Nourani

Background: Sample preparation is one of the most challenging phases in pharmaceutical analysis, especially in biological matrices, affecting the whole analytical methodology. Objective: In this study, a new Ca(II)/Cu(II)/alginate/CuO nanoparticles hydrogel fiber (CCACHF) was synthesized through a simple, green procedure and applied for fiber micro solid phase extraction (FMSPE) of diazepam (DIZ) and oxazepam (OXZ) as model drugs prior to high-performance liquid chromatography-UV detection (HPLC-UV). Methods: Composition and morphology of the prepared fiber were characterized and the effect of main parameters on the fiber fabrication and extraction efficiency have been studied and optimized. Results: In optimal conditions, calibration curves were linear ranging between 0.1–500 µg L−1 with regression coefficients of 0.9938 and 0.9968. Limit of detection (LOD) (S/N=3) and limit of quantification (LOQ) (S/N=10) of the technique for DIZ and OXZ were 0.03 to 0.1 µg L−1. Within-day and between-day relative standard deviations (RSDs) for DIZ and OXZ were 6.0–12.5% and 3.3–9.4%, respectively. Conclusion: The fabricated adsorbent has been substantially employed to extraction of selected benzo-diazepines (BZDs) from human serum real specimens and the obtained recoveries were also satisfactory (82.1-109.7%).


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Indhu Priya Mabbu ◽  
G. Sumathi ◽  
N. Devanna

Abstract Background The aim of the present method is to develop and validate a specific, sensitive, precise, and accurate liquid chromatography-mass spectrometry (LC-MS) method for the estimation of the phenyl vinyl sulfone in the eletriptan hydrobromide. The effective separation of the phenyl vinyl sulfone was achieved by the Symmetry C18 (50 × 4.6 mm, 3.5 μm) column and a mobile phase composition of 0.1%v/v ammonia buffer to methanol (5:95 v/v), using 0.45 ml/min flow rate and 20 μl of injection volume, with methanol used as diluent. The phenyl vinyl sulfone was monitored on atomic pressure chemical ionization mode mass spectrometer with positive polarity mode. Results The retention time of phenyl vinyl sulfone was found at 2.13 min. The limit of detection (LOD) and limit of quantification (LOQ) were observed at 1.43 ppm and 4.77 ppm concentration respectively; the linear range was found in the concentration ranges from 4.77 to 27.00 ppm with regression coefficient of 0.9990 and accuracy in the range of 97.50–102.10%. The percentage relative standard deviation (% RSD) for six replicates said to be injections were less than 10%. Conclusion The proposed method was validated successfully as per ICH guidelines. Hence, this is employed for the determination of phenyl vinyl sulfone in the eletriptan hydrobromide.


Molecules ◽  
2021 ◽  
Vol 26 (7) ◽  
pp. 1837
Author(s):  
Harischandra Naik Rathod ◽  
Bheemanna Mallappa ◽  
Pallavi Malenahalli Sidramappa ◽  
Chandra Sekhara Reddy Vennapusa ◽  
Pavankumar Kamin ◽  
...  

A quick, sensitive, and reproducible analytical method for the determination of 77 multiclass pesticides and their metabolites in Capsicum and tomato by gas and liquid chromatography tandem mass spectrometry was standardized and validated. The limit of detection of 0.19 to 10.91 and limit of quantification of 0.63 to 36.34 µg·kg−1 for Capsicum and 0.10 to 9.55 µg·kg−1 (LOD) and 0.35 to 33.43 µg·kg−1 (LOQ) for tomato. The method involves extraction of sample with acetonitrile, purification by dispersive solid phase extraction using primary secondary amine and graphitized carbon black. The recoveries of all pesticides were in the range of 75 to 110% with a relative standard deviation of less than 20%. Similarly, the method precision was evaluated interms of repeatability (RSDr) and reproducibility (RSDwR) by spiking of mixed pesticides standards at 100 µg·kg−1 recorded anRSD of less than 20%. The matrix effect was acceptable and no significant variation was observed in both the matrices except for few pesticides. The estimated measurement uncertainty found acceptable for all the pesticides. This method found suitable for analysis of vegetable samples drawn from market and farm gates.


2015 ◽  
Vol 12 (1) ◽  
pp. 167-177 ◽  
Author(s):  
Baghdad Science Journal

A spectrophotometric method has been proposed for the determination of two drugs containing phenol group [phenylephrine hydrochloride (PHP) and salbutamol sulphate (SLB)] in pharmaceutical dosage forms. The method is based on the diazotization reaction of metoclopramide hydrochloride (MCP) and coupling of the diazotized reagent with drugs in alkaline medium to give intense orange colored product (?max at 470 nm for each of PHP and SLB). Variable parameters such as temperature, reaction time and concentration of the reactants have been analyzed and optimized. Under the proposed optimum condition, Beer’s law was obeyed in the concentration range of 1-32 and 1-14 ?g mL-1 for PHP and SLB, respectively. The limit of detection (LOD) and limit of quantification (LOQ) for each of PHP and SLB were 0.60, 0.52 ?g mL-1 and 2.02, 1.72 ?g mL-1, respectively. No interference was observed from common excipients present in pharmaceutical preparations. The good correlation coefficients and low relative standard deviation assert the applicability of this method. The suggested method was further applied for the determinations of drugs in commercial pharmaceutical preparations, which was compared statistically with reference methods by means of t- test and F- test and were found not to differ significantly at 95% confidence level. The procedure was characterized by its simplicity with accuracy and precision.


2013 ◽  
Vol 3 (1) ◽  
pp. 208-210
Author(s):  
Nia Kristiningrum ◽  
Ellsy Novita Martyanti

A rapid, reproducible and accurate TLC method was developed for the determination of Cetirizine Dihydrochloride in tablet. The analytes were dissolved with ethanol 70% and chromatographed on silica Gel GF 254 TLC plate using chloroform : methanol : ethyl acetate in the ratio of 2 : 7 : 3 (v/v) as mobile phase. Quantitative analysis was done through densitometric measurement at wavelength 234 nm. Method was found linear over the concentration range of 400 – 1600 ng/spot with the correlation coefficient of 0.996. Specificity showed calculation of purity and identity more than 0.99. The limit of detection (LOD) and the limit of quantification (LOQ) of the method were 75.54 and 226.64 ng/spot. The relative standard deviation of this method was 0.86% whereas the means of the recovery data was 100.54 ± 0.11%. The proposed method has been applied to the determination of Cetirizine Dihydrochloride in commercial tablet formulations and the result were 96.97 ± 0.86 % for brand A and 100.57 ± 1.17 % for brand B. The developed method was successfully used for the assay of Cetirizine Dihydrochloride. This method is simple, sensitive and precise; it can be used for the routine quality control testing of marketed formulations.DOI: http://dx.doi.org/10.3329/icpj.v3i1.17294 International Current Pharmaceutical Journal, December 2013, 3(1): 208-210


2012 ◽  
Vol 2012 ◽  
pp. 1-5
Author(s):  
Jiangman Liu ◽  
Huan Yang ◽  
Yun Zhang ◽  
Min Wu ◽  
Haixiang Zhao ◽  
...  

A sensitive chemiluminescence (CL) method, based on the inhibitory effect of roxithromycin (ROX) on the CL reaction between luminol and dissolved oxygen in a flow-injection system, was first proposed for the determination of ROX at picogram levels. The decrement of CL intensity was linearly proportional to the logarithm of ROX concentrations ranging from 0.1 to 100 pg mL-1, giving the limit of detection (LOD) of 0.03 pg mL-1 (3σ). At a flow rate of 2.0 mL min-1, a complete analytical procedure including sampling and washing could be performed within 0.5 min, with relative standard deviations (RSDs) of less than 5.0% (n=5). The proposed procedure was applied successfully to the determination of ROX in pharmaceutical, human serum, and urine with the recoveries ranging from 90.0 to 110.0%.


2013 ◽  
Vol 2013 ◽  
pp. 1-5
Author(s):  
Neelkant Prasad ◽  
Roshan Issarani ◽  
Badri Prakash Nagori

A simple and sensitive ultraviolet spectrophotometric method for quantitative estimation of glipizide in presence of lipid turbidity is described to avoid false estimation due to diffraction by turbidity. UV detection was performed at 230 nm, 225 nm, and 235 nm, and the calibration curve was plotted between resultant of absorbance of [230 nm − (225 nm + 235 nm)/2] and concentration of analyte. The calibration curve was linear over the concentration range tested (1–20 μg/mL) with limit of detection of 0.27 μg/mL and limit of quantification of 0.82 μg/mL. Percent relative standard deviations and percent relative mean error, representing precision and accuracy, respectively, for clear as well as turbid solutions, were found to be within acceptable limits, that is, always less than 0.69 and 0.41, respectively, for clear solution and 0.65 and 0.47, respectively, for turbid solution. Conclusively, our method was successfully applied for the determination of glipizide in clear as well as turbid solutions, and it was found that the drug analyte in both types of solutions can be detected from the same calibration curve accurately and precisely and glipizide entrapped in the liposomes or in proliposomal matrix was not detected.


Author(s):  
DAVID ALEXANDER ◽  
Abdul Rohman

Objective: The aim of this research was to validate inductively coupled plasma-atomic emission spectroscopy (ICP-AES) for quantitative analysis of cadmium (Cd), chromium (Cr), cuprum (Cu), mangan (Mn) and nickel (Ni) in milk products. Methods: The heavy metals in milk were determined using ICP-AES at optimized wavelength. The method was validated by assessing several validation parameters which included linearity and range, accuracy, precision and sensitivity expressed by the limit of detection and limit of quantification. The validated method was then used for the analysis of milks commercially available. Results: ICP-AES for determination of Cd, Cr, Cu, Mn, and Ni was linear over a certain concentration range with a coefficient correlation value of>0.997. The limit of quantification values of Cd, Cr, Cu, Mn, and Ni were 0.0047; 0.0050; 0.0066; 0.0061; and 0.0169 µg/ml, respectively. The precision of analytical method exhibited relative standard deviation (RSD) values of 3.18%; 4.17%; 3.05%; 2.93%; and 4.47% during repeatability test and 5.28%; 5.06%; 3.67%; 3.67%; and 11.17% during intermediate precision of Cd, Cr, Cu, Mn, and Ni respectively. The recoveries of these metals assessed using standard addition method were 92.25; 90.88; 102.87; 94.50; and 86.85%, respectively. Conclusion: ICP-AES offered a reliable and fast method for the determination of heavy metals in milk products. The developed method could be proposed as an official method for determination of heavy metals in milk products.


2020 ◽  
Vol 32 (6) ◽  
pp. 1314-1320
Author(s):  
Lamya A. Sarsam ◽  
Salim A. Mohammed ◽  
Sahar A. Fathe

A rapid, simple and sensitive spectrophotometric and RP-HPLC methods have been developed for the quantitative determination of cefotaxime-Na in both pure and dosage forms. The spectrophotometric method was based on diazotization of cefotaxime-Na and then coupling with 8-hydroxyquinoline in an alkaline medium. The resulting azo dye exhibited maximum absorption at 551 nm with a molar absorptivity of 0.597 × 104 L mol-1 cm-1. Beer′s law was obeyed over the range 10-700 μg/25 mL (i.e. 0.4-28.0 ppm) with an excellent determination coefficient (R2 = 0.9993). The limit of detection (LOD) and limit of quantification (LOQ) were found to be 0.0194 and 0.3765 μg mL-1, respectively. The recoveries were obtained in the range 97.3-102.5% and the relative standard deviation (RSD) was better than ± 1.56. The HPLC method has been developed for the determination of cefotaxime-Na. The analysis were carried out on a C18 column and a mobile phase composed of acetonitrile and phosphate buffer solution (0.024M KH2PO4 and 0.01M H3PO4) at pH 3.5 in the ratio of 60:40 (v:v), with a flow rate of 1.0 mL min-1 and UV detection at 258 nm. The proposed method showed good linearity (in a range of concentration 1.0-200 μg mL-1. The recovery percent and a relative standard deviations were found in the range 96 to 104.8% and ± 0.017 to ± 0.031%, respectively. Both methods were applied successfully to the assay of cefotaxime-Na in commercial injection preparations.