scholarly journals Experimental Investigation of Heat Transfer of Nanofluid in Elliptical and Circular Tubes

2021 ◽  
Vol 8 (4) ◽  
pp. 665-671
Author(s):  
Ammar M. Al-Tajer ◽  
Abdulhassan A. Kramallah ◽  
Ali M. Mohsen ◽  
Nabeel Sameer Mahmoud

The paper presents experimental comparison of forced convection for steady state turbulent flow of nanofluid (Al2O3-distilled water) inside circular and elliptical (aspect ratio of 0.75) cross section tubes of identical circumference and tube surface area. Convection coefficient, pressure change, and fiction factor were compared at different Reynolds number (3,000-9,230) with different nanoparticles volume concentration (0.5%, 1.0%, and 1.5%). The results showed that Nusselt number increases with increasing Reynolds number and nanoparticle volume concentration. The pressure drops and friction factor of nanofluid are higher than the distilled water and are increasing as the volume concentration increases. Furthermore, the elliptical tube provided small increase in Nusselt number compared to that of circular cross sectional tube. However, the friction factor in the elliptical tube was slightly higher.

2013 ◽  
Vol 2013 ◽  
pp. 1-12 ◽  
Author(s):  
Adnan M. Hussein ◽  
K. V. Sharma ◽  
R. A. Bakar ◽  
K. Kadirgama

The additives of solid nanoparticles to liquids are significant enhancement of heat transfer and hydrodynamic flow. In this study, the thermal properties of three types of nanoparticles (Al2O3, TiO2, and SiO2) dispersed in water as a base fluid were measured experimentally. Forced convection heat transfer turbulent flow inside heated flat tube was numerically simulated. The heat flux around flat tube is 5000 W/m2and Reynolds number is in the range of5×103to50×103. CFD model by finite volume method used commercial software to find hydrodynamic and heat transfer coefficient. Simulation study concluded that the thermal properties measured and Reynolds number as input and friction factor and Nusselt number as output parameters. Data measured showed that thermal conductivity and viscosity increase with increasing the volume concentration of nanofluids with maximum deviation 19% and 6%, respectively. Simulation results concluded that the friction factor and Nusselt number increase with increasing the volume concentration. On the other hand, the flat tube enhances heat transfer and decreases pressure drop by 6% and −4%, respectively, as compared with circular tube. Comparison of numerical analysis with experimental data available showed good agreement with deviation not more than 2%.


2020 ◽  
Vol 10 (5) ◽  
pp. 610-621
Author(s):  
Taliv Hussain ◽  
Mohammad T. Javed

Introduction: A numerical study is performed in which the friction factor and forced convection heat transfer is studied for Al2O3 nanoparticle dispersed in water as a base fluid. Methods: Four concentrations of nanofluids in the range of 0-2.5 vol% have been simulated. The Reynolds Number is varied in the range of 100-500 by varying inlet velocity. Cross flow of air is assumed over the pipe with air velocity of 2.2 m/s. Results: The results depict that the friction factor decreases with an increase in flow rate and increases with increase in volume concentration. The maximum deviation for friction factor obtained by simulation from that obtained using Darcy’s relation is about 21.5% for water. Nusselt number increases with increase in Reynolds Number and nanofluid volume concentration with a maximum of 7653.68 W/m2 at a nanoparticle concentration of 2.5% and Reynolds Number of 500. Heat transfer rate enhancement of upto 13.6% is obtained as compared to pure water. The maximum increase in Nusselt Number is about 13.07% for a nanoparticle concentration of 2.5%. Conclusion: The simulation results are compared with established relations obtained by other researchers and there is a good agreement in terms of trends obtained. The deviations from established relations are also depicted.


2017 ◽  
Vol 21 (6 Part A) ◽  
pp. 2379-2391 ◽  
Author(s):  
Murat Unverdi ◽  
Yasar Islamoglu

In this study, heat transfer and pressure drop characteristics have been experimentally investigated by using Al2O3-water nanofluids in the chevron-type plate heat exchanger. The purpose of the experiments was to determine the heat transfer coefficient and pressure drop for different flow rates of 90, 120, 150, 180, 240, and 300 kg/h and different volume concentrations of 0.25%, 0.5%, 0.75%, and 1% of the nanofluids. The Nusselt number of the nanofluids increased with the increasing volume concentration and flow rate at constant hot water flow rate and constant inlet temperatures. The increase in the Nusselt number is 42.4% when compared to distilled water at the maximum volume concentration and Reynolds number (600 ? Re ? 1900) in the nanofluids-plate heat exchanger. It has been concluded that nanofluids enhanced the heat transfer significantly and pressure drops at the maximum volume concentration and the Reynolds number increased by between 6.4% and 8.4% compared to distilled water.


2014 ◽  
Vol 136 (11) ◽  
Author(s):  
Jian-Zhong Lin ◽  
Yi Xia ◽  
Xiao-Ke Ku

Numerical simulations of Al2O3/water nanofluid in turbulent pipe flow are performed with considering the particle convection, diffusion, coagulation, and breakage. The distributions of particle volume concentration, the friction factor, and heat transfer characteristics are obtained. The results show that the initial uniform distributions of particle volume concentration become nonuniform, and increase from the pipe wall to the center. The nonuniformity becomes significant along the flow direction from the entrance and attains a steady state gradually. Friction factors increase with the increase of particle volume concentrations and particle diameter, and with the decrease of Reynolds number. The friction factors increase remarkably at lower volume concentration, while slightly at higher volume concentration. The presence of nanoparticles provides higher heat transfer than pure water. The Nusselt number of nanofluids increases with increasing Reynolds number, particle volume concentration, and particle diameter. The rate increase in Nusselt number at lower particle volume concentration is more than that at higher concentration. For a fixed particle volume concentration, the friction factor is smaller while the Nusselt number is larger for the case with uniform distribution of particle volume concentration than that with nonuniform distribution. In order to effectively enhance the heat transfer using nanofluid and simultaneously save energy, it is necessary to make the particle distribution more uniform. Finally, the expressions of friction factor and Nusselt number as a function of particle volume concentration, particle diameter and Reynolds number are derived based on the numerical data.


1989 ◽  
Vol 111 (1) ◽  
pp. 51-58 ◽  
Author(s):  
S. C. Lau ◽  
J. C. Han ◽  
Y. S. Kim

Experiments were conducted to study the effects of lateral flow ejection on the overall heat transfer and pressure drops for turbulent flow through pin fin channels. The two test sections of the investigation were rectangular channels with staggered arrays of six and eight streamwise rows of pins, respectively. The pin length-to-diameter ratio was one and both the streamwise and spanwise pin spacings were 2.5 times the pin diameter. Heat transfer and friction data were obtained for various ejection exit geometries, for ejection ratios between 0 and 1, and for Reynolds numbers between 6000 and 60,000. The results of the study show that, for any given ejection ratio, the overall Nusselt number increases with increasing Reynolds number. However, the overall Nusselt number is reduced by as much as 25 percent as the ejection ratio is increased from 0 to 1 over the range of Reynolds number studied. The Nu–Re–ε relationship, which is insensitive to varying the ejection exit geometry, can be correlated by the equation (Nu/Nu0) = (Nu1/Nu0)ε, where Nu0 = c0Rem and Nu1 = c1Ren are the overall Nusselt numbers in the 0 and 100 percent lateral flow ejection cases, respectively. The results also show that the overall friction factor is independent of the flow Reynolds number over the range of Reynolds number studied. However, the friction factor is strongly dependent on the ejection ratio as well as the geometries of the straight flow exit and lateral ejection flow exit.


Fluids ◽  
2020 ◽  
Vol 5 (4) ◽  
pp. 202
Author(s):  
Malik Muhammad Nauman ◽  
Muhammad Sameer ◽  
Murtuza Mehdi ◽  
Asif Iqbal ◽  
Zulfikre Esa

Co-relations of friction factor and Nusselt number for plain tubes have been widely developed, but less analysis has been done for tubes with wavy surfaces. This paper uses the Computational Fluid Dynamics (CFD) tool for the analysis of heat transfer and pressure drop in wavy-walled tubes, which can be utilized as a heating element for fluids. An investigation was done for the effect of Reynolds number (Re) and wavy-walled tube geometry on friction factor and Nusselt number of laminar and turbulent flow inside wavy-walled tubes. The numerical results and experimental comparison indicate that heat transfer and pressure drop for water are significantly affected by wavy-walled tube parameters and flow Reynolds number. These wavy-walled tubes are capable of increasing the heat transfer to or from a fluid by an order of magnitude but at an expense of higher pumping power. This ratio was found to remain at the minimum at a wave factor of 0.83 for 34 < Re < 3500 and maximum at a wave factor of 0.15 for 200 < Re < 17,000. New correlations of friction factor and Nusselt number based on wavy-walled tube parameters are proposed in this paper, which can serve as design equations for predicting the friction factor and heat transfer in wavy-walled tubes under a laminar and turbulent regime with less than 10% error. The quantitative simulation results match the experimental results with less than 15% error. The qualitative comparison with the experiments indicates that the simulations are well capable of accurately predicting the circulation zones within the bulgy part of the tubes.


Author(s):  
L. Syam Sundar ◽  
Antonio C. M. Sousa ◽  
Manoj Kumar Singh

In this paper, it is estimated the heat transfer coefficient and friction factor for fully developed turbulent flow of carbon nanotube (CNT)-Fe3O4/water hybrid nanofluids flow through a tube with twisted tape inserts at constant heat flux conditions. The nanocomposite of CNT-Fe3O4 was prepared by in situ method; which contains dispersion of carboxylated-CNTs in distilled water followed by mixing of ferrous chloride and ferric chloride in the molar ratio of 2:1. Sodium hydroxide was used as reducing agent to form CNT-Fe3O4 nanocomposite. The detailed surface morphology and magnetic properties were performed by X-ray diffraction and scanning electron microscopy (SEM), and vibrating sample magnetometer (VSM). The stable hybrid nanofluids were prepared by dispersing nanocomposite in distilled water, and the heat transfer and friction factor experiments were conducted for particle volume concentrations of 0.1% and 0.3%. The results indicate that a maximum of 31.10% enhancement in Nusselt number with a penalty of 1.18-times increase of pumping power was observed for particle concentration of 0.3% at a Reynolds number of 22,000 as compared to base fluid data. The Nusselt number is further enhanced to 42.51% for 0.3% nanofluid flow through a tube with twisted tape of H/D = 5 at a Reynolds number of 22,000 compared to base fluid data. The empirical correlations were proposed for the estimation of Nusselt number and friction factor to match well with the experimental data.


2021 ◽  
Vol 321 ◽  
pp. 04014
Author(s):  
Hussein Togun

In this paper, 3D Simulation of turbulent Fe3O4/Nanofluid annular flow and heat transfer in sudden expansion are presented. k-ε turbulence standard model and FVM are applied with Reynolds number different from 20000 to 50000, enlargement ratio (ER) varied 1.25, 1.67, and 2, , and volume concentration of Fe3O4/Nanofluid ranging from 0 to 2% at constant heat flux of 4000 W/m2. The main significant effect on surface Nusselt number found by increases in volume concentration of Fe3O4/Nanofluid for all cases because of nanoparticles heat transport in normal fluid as produced increases in convection heat transfer. Also the results showed that suddenly increment in Nusselt number happened after the abrupt enlargement and reach to maximum value then reduction to the exit passage flow due to recirculation flow as created. Moreover the size of recirculation region enlarged with the rise in enlargement ratio and Reynolds number. Increase of volume Fe3O4/nanofluid enhances the Nusselt number due to nanoparticles heat transport in base fluid which raises the convection heat transfer. Increase of Reynolds number was observed with increased Nusselt number and maximum thermal performance was found with enlargement ratio of (ER=2) and 2% of volume concentration of Fe3O4/nanofluid. Further increases in Reynolds number and enlargement ratio found lead to reductions in static pressure.


2008 ◽  
Vol 130 (9) ◽  
Author(s):  
Ghislain Michaux ◽  
Olivier Vauquelin ◽  
Elsa Gauger

An experimental procedure was developed for determining both the density and flow rate of a gas from measurements of pressure drops caused by an abrupt flow area contraction in a cylindrical pipe. Experiments were carried out by varying the density and flow rate of a light gas mixture of air and helium, spanning a Reynolds number range from 0.2×104 to 3.4×104. From experimental results, a procedure was then proposed for evaluating the density from pressure change measurements in the scope of light gas extraction experiments.


Author(s):  
Abdalla Gomaa ◽  
Wael IA Aly ◽  
Ashraf Mimi Elsaid ◽  
Eldesuki I Eid

In the present study, the thermo-fluid characteristics of a spirally coiled finned tube in cross flow were experimentally investigated. This investigation covered different design parameters such as curvature ratio, air velocity, flow direction, fin pitch and flow rate of chilled water on performance characteristics of the spirally coiled finned tube. The purpose was to evaluate this kind of the spirally finned-tube cooling coils with particular reference to bare coiled tube. Six test specimens were designed and manufactured with curvature ratios of 0.027, 0.03, 0.04, tube pitches of 18, 20, 30 mm and fin pitches of (33, 22, 11 mm). Experiments were carried out in a pilot wind tunnel with air Reynolds number ranging from 35,500 to 245,000. Two types of chilled water flow directions entering the spiral coil were tested at Reynolds number ranging from 5700 to 25,300, the first was inward flow direction and the other was to outward flow direction. The results revealed that the inward flow direction has significant enhancement effect on the Nusselt number compared with outward flow direction by 37.0% for tube pitch of 18 mm and curvature ratio of 0.027. The decrease of fin pitch enhances the Nusselt number by 21.92% on expense of friction factor by 10.9%. In the case of spirally coiled bare tube, the decreasing of the curvature ratio increases air side Nusselt number by 33.69% on expense of friction factor by 18.36%. General correlations of Nusselt number and air friction factor for bare and finned spirally coiled tube were correlated based on reported experimental data.


Sign in / Sign up

Export Citation Format

Share Document