scholarly journals Use of an Outdoor Swimming Pool as Seasonal Heat Source in Heat Pump Applications

2021 ◽  
Vol 65 (2-4) ◽  
pp. 337-344
Author(s):  
Giuseppe Emmi ◽  
Alessia Natali ◽  
Silvia Cesari ◽  
Patrizio Fausti ◽  
Michele Bottarelli

The improvement of energy efficiency in the building sector is one of the most promising actions for achieving the energy and environmental goals of the European Community. The deep retrofit of buildings is obviously the best solution in terms of energy performance result. When the deep retrofit is not allowed or possible, the simple maintenance of the building envelope and plant is usually done to assure the operation over time. This type of intervention could require the installation of new HVAC systems that could include a HP, which nowadays represents one of the key devices for the energy saving and the sustainable development. This work regards the study of the energy performance of a swimming Pool Centre in North-East Italy. The objective of this work is the exploitation of an outdoor swimming pool as a heat source for a HP system. The HP system uses two different heat sources, the air and the water. The final SCOP of the double source HP system has been calculated and compared with an air source HP solution. This analysis has been carried out by means of dynamic energy simulations in TRNSYS environment.

Author(s):  
C. León-Sánchez ◽  
D. Giannelli ◽  
G. Agugiaro ◽  
J. Stoter

Abstract. The 3D BAG v. 2.0 dataset has been recently released: it is a country-wide dataset containing all buildings in the Netherlands, modelled in multiple LoDs (LoD1.2, LoD1.3 and LoD2.2). In particular, the LoD2.2 allows differentiating between different thematic surfaces composing the building envelope. This paper describes the first steps to test and use the 3D BAG 2.0 to perform energy simulations and characterise the energy performance of the building stock. Two well-known energy simulation software packages have been tested: SimStadt and CitySim Pro. Particular care has been paid to generate a suitable, valid CityGML test dataset, located in the municipality of Rijssen-Holten in the central-eastern part of the Netherlands, that has been then used to test the energy simulation tools. Results from the simulation tools have been then stored into the 3D City Database, additionally extended to deal with the CityGML Energy ADE. The whole workflow has been checked in order to guarantee a lossless dataflow.The paper reports on the proposed workflow, the issues encountered, some solutions implemented, and what the next steps will be.


2021 ◽  
Vol 312 ◽  
pp. 02006
Author(s):  
Domenico Palladino ◽  
Domenico Iatauro ◽  
Paolo Signoretti

The Energy Performance of Buildings Directive (EPBD 2018/844/EU) requires to Member States to upgrade the methodology for the energy performance assessment of buildings. The current calculation method, based on the monthly quasi steady state calculation procedure, could be replaced in the next years by an hourly dynamic calculation procedure (EN ISO 52016), in which a resistance-capacity (RC) model is implemented to consider with more accuracy the heat exchange through the building envelope. In this framework, the present work aims at analysing and comparing the energy needs of three reference case studies of nearly Zero Energy Buildings (nZEB), applying both calculation procedures in order to investigate the main difference of the two approaches. Two residential buildings and one office, compliant with Italian minimum requirements for nZEB, were defined, and several energy simulations were carried out for all different climatic zones of Italian territory. Preliminary results highlighted significant differences of energy need mainly due to different weight of heat loss and heat gains obtained with the two considered calculation methods. This paper represents a preliminary study, but further analysis are recommended in order to evaluate the overall energy use for different type and different operation profile of buildings.


2019 ◽  
Vol 111 ◽  
pp. 03030
Author(s):  
Hilde Breesch ◽  
Barbara Wauman ◽  
Marcus Peeters

Unlike other types of buildings, commercial and industrial buildings have been so far “forgotten”. In addition, EPBD requirements are increasingly challenging for this type of buildings. This paper aims to identify the most building determinants of the energy performance of commercial and industrial buildings, focussing on the building envelope. Building energy simulations (BES) in TRNSYS are used to simulate the energy demand for heating and cooling in five building variants. The Pareto optimality approach that considers the economic and energetic objectives equally, is used to determine the cost-optimal solutions. The sensitivity analysis and cost-optimal study clearly reveal that airtightness seems to be the most important factor. Although heat recovery on a balanced mechanical ventilation system has a major impact on the energy demand for heating, this measure is not cost-optimal. The large impact of the U-value of the roof on the energy demand for heating is also reflected in the cost-optimal study. The insulation of the floor do not appear to be cost-optimal. Moreover, attention to construction detailing is important. The additional energy losses that can occur due to thermal bridges quickly reach significant values although solving the thermal bridges seems not to be cost-optimal.


2020 ◽  
pp. 50-64
Author(s):  
Kuladeep Kumar Sadevi ◽  
Avlokita Agrawal

With the rise in awareness of energy efficient buildings and adoption of mandatory energy conservation codes across the globe, significant change is being observed in the way the buildings are designed. With the launch of Energy Conservation Building Code (ECBC) in India, climate responsive designs and passive cooling techniques are being explored increasingly in building designs. Of all the building envelope components, roof surface has been identified as the most significant with respect to the heat gain due to the incident solar radiation on buildings, especially in tropical climatic conditions. Since ECBC specifies stringent U-Values for roof assembly, use of insulating materials is becoming popular. Along with insulation, the shading of the roof is also observed to be an important strategy for improving thermal performance of the building, especially in Warm and humid climatic conditions. This study intends to assess the impact of roof shading on building’s energy performance in comparison to that of exposed roof with insulation. A typical office building with specific geometry and schedules has been identified as base case model for this study. This building is simulated using energy modelling software ‘Design Builder’ with base case parameters as prescribed in ECBC. Further, the same building has been simulated parametrically adjusting the amount of roof insulation and roof shading simultaneously. The overall energy consumption and the envelope performance of the top floor are extracted for analysis. The results indicate that the roof shading is an effective passive cooling strategy for both naturally ventilated and air conditioned buildings in Warm and humid climates of India. It is also observed that a fully shaded roof outperforms the insulated roof as per ECBC prescription. Provision of shading over roof reduces the annual energy consumption of building in case of both insulated and uninsulated roofs. However, the impact is higher for uninsulated roofs (U-Value of 3.933 W/m2K), being 4.18% as compared to 0.59% for insulated roofs (U-Value of 0.33 W/m2K).While the general assumption is that roof insulation helps in reducing the energy consumption in tropical buildings, it is observed to be the other way when insulation is provided with roof shading. It is due to restricted heat loss during night.


2020 ◽  
Vol 10 (13) ◽  
pp. 4489
Author(s):  
Zakaria Che Muda ◽  
Payam Shafigh ◽  
Norhayati Binti Mahyuddin ◽  
Samad M.E. Sepasgozar ◽  
Salmia Beddu ◽  
...  

The increasing need for eco-friendly green building and creative passive design technology in response to climatic change and global warming issues will continue. However, the need to preserve and sustain the natural environment is also crucial. A building envelope plays a pivotal role in areas where the greatest heat and energy loss often occur. Investment for the passive design aspect of building envelopes is essential to address CO 2 emission. This research aims to explore the suitability of using integral-monolithic structural insulation fibre-reinforced lightweight aggregate concrete (LWAC) without additional insulation as a building envelope material in a high-rise residential building in the different climatic zones of the world. Polypropylene and steel fibres in different dosages were used in a structural grade expanded clay lightweight aggregate concrete. Physical and thermal properties of fibre reinforced structural LWAC, normal weight concrete (NWC) and bricks were measured in the lab. The Autodesk@Revit-GBS simulation program was implemented to simulate the energy consumption of a 29-storey residential building with shear wall structural system using the proposed fibre-reinforced LWAC materials. Results showed that energy savings between 3.2% and 14.8% were incurred in buildings using the fibre-reinforced LWAC across various climatic regions as compared with traditional NWC and sand-cement brick and clay brick walls. In conclusion, fibre-reinforced LWAC in hot-humid tropical and temperate Mediterranean climates meet the certified Green Building Index (GBI) requirements of less than 150 kW∙h∙m−2. However, in extreme climatic conditions of sub-arctic and hot semi-arid desert climates, a thicker wall or additional insulation is required to meet the certified green building requirements. Hence, the energy-saving measure is influenced largely by the use of fibre-reinforced LWAC as a building envelope material rather than because of building orientation.


2019 ◽  
Vol 13 (2) ◽  
pp. 129-133
Author(s):  
Gennadiy Farenyuk

The paper presents the basic methodical principles for the time analysis of the variations of envelope structures’ thermal insulation properties and for the substantiation of the thermal reliability criterion, which should allow the analysis of the actual parameters of heat losses during the operation of buildings. In the paper, the state of the envelope structures thermal failure, the concept of building thermal envelope thermal reliability and the principles of its rating are defined. The physical meaning and basic criterion of the envelope structure thermal reliability are formulated. The application of the thermal reliability criterion allows determining the probable variations in the thermal insulation properties during the building operation and, accordingly, the changes of the building energy performance over time.


2021 ◽  
Vol 13 (8) ◽  
pp. 4175
Author(s):  
Islam Boukhelkhal ◽  
Fatiha Bourbia

The building envelope is the barrier between the interior and exterior environments. It has many important functions, including protecting the interior space from the climatic variations through its envelope materials and design elements, as well as reduction of energy consumption and improving indoor thermal comfort. Furthermore, exterior building sidings, in addition to their aesthetic appearance, can have useful textures for reducing solar gains and providing good thermal insulation performance. This research examined and evaluated the effect of external siding texture and geometry on energy performance. For this objective, a field in situ testing and investigation of surface temperature was carried out on four samples (test boxes) with different exterior textures and different orientations, under the climate zone of Constantine–Algeria during the summer period. The results indicated significant dependability between the exterior texture geometry, the percentage of shadow projected, and external surface temperature. The second part of the research involved a similar approach, exploring the effect of three types of particles with the same appearance but with different thermal characteristics. It was concluded that the natural plant aggregates “palm particles” had the best performance, which contributed to a significant reduction of external surface temperature reaching 4.3 °C, which meant decreasing the energy consumption.


2014 ◽  
Vol 1056 ◽  
pp. 128-130
Author(s):  
Fu Yun Yang

Doors and windows of the building is an important part of the building envelope. AS the transparent and open envelope of the building, doors and windowsare the weakest part in the winter and summer heat preservation. It directly affects the energy performance of buildings. Therefore, do a good job of building doors and windows energy saving is an important way to optimize the indoor environment and realize energy saving.


Sign in / Sign up

Export Citation Format

Share Document