scholarly journals Reliability / Security of Distribution System Network under Supporting by Distributed Generation

2019 ◽  
Vol 2 (1) ◽  
pp. 1 ◽  
Author(s):  
Ali M. Eltamaly ◽  
Yehia Sayed Mohamed ◽  
Abou-Hashema M. El-Sayed ◽  
Amer Nasr A. Elghaffar

<p>This paper discusses the impact of Distributed Generator (DG) on the power system for enhancing the power system quality by improving the voltage profile and power losses reduction. With the increasing on the demand power and the power system extension, the distributed renewable energy technologies are becoming increasingly important in the energy supply systems of many countries. DGs units can be defined as a small-units that generate electric power near to the location of customers based on the renewable energy techniques, including wind energy, solar energy, and geothermal energy. Interconnecting DG to an existing distribution system provides various benefits to several entities as for example the owner, utility and the final user. DG provides an enhanced power quality, higher reliability of the distribution system and can peak shaves and fill valleys. However, the integration of DG into existing networks has associated several technical, economic and regulatory questions. Also, this paper uses the power system IEEE-12 busses for an example to illustrate the voltage control and decreases the active and reactive power losses by adding the wind generation DGs with the distribution network. </p>

Author(s):  
Su Hlaing Win ◽  
Pyone Lai Swe

A Radial Distribution network is important in power system area because of its simple design and reduced cost. Reduction of system losses and improvement of voltage profile is one of the key aspects in power system operation. Distributed generators are beneficial in reducing losses effectively in distribution systems as compared to other methods of loss reduction. Sizing and location of DG sources places an important role in reducing losses in distribution network. Four types of DG are considered in this paper with one DG installed for minimize the total real and reactive power losses. The objective of this methodology is to calculate size and to identify the corresponding optimum location for DG placement for minimizing the total real and reactive power losses and to improve voltage profile   in primary distribution system. It can obtain maximum loss reduction for each of four types of optimally placed DGs. Optimal sizing of Distributed Generation can be calculated using exact loss formula and an efficient approach is used to determine the optimum location for Distributed Generation Placement.  To demonstrate the performance of the proposed approach 36-bus radial distribution system in Belin Substation in Myanmar was tested and validated with different sizes and the result was discussed.


2014 ◽  
Vol 2014 ◽  
pp. 1-9 ◽  
Author(s):  
Sanjay Jain ◽  
Ganga Agnihotri ◽  
Shilpa Kalambe ◽  
Renuka Kamdar

This paper intends to enumerate the impact of distributed generation (DG) on distribution system in terms of active as well as reactive power loss reduction and improved voltage stability. The novelty of the method proposed in this paper is the simple and effective way of sizing and siting of DG in a distribution system by using two-port Z-bus parameters. The validity of the method is verified by comparing the results with already published methods. Comparative study presented has shown that the proposed method leads existing methods in terms of its simplicity, undemanding calculation procedures, and less computational efforts and so does the time. The method is implemented on IEEE 69-bus test radial distribution system and results show significant reduction in distribution power losses with improved voltage profile of the system. Simulation is carried out in MATLAB environment for execution of the proposed algorithm.


2018 ◽  
Vol 7 (3.15) ◽  
pp. 1
Author(s):  
Nabil Fikri Ruslan ◽  
Ismail Musirin ◽  
Mohamad Khairuzzaman Mohamad Zamani ◽  
Muhammad Murtadha Othman ◽  
Zulkiffli Abdul Hamid ◽  
...  

General power flow studies do not manage to trace the contributors by generators on power losses in the whole power transmission system. Thus, power tracing approach is utilized to address this issue. Power tracing is a termed used to describe the contributors for the power losses dissipated on the transmission line. The traditional technique made use the knowledge of circuit analysis such as cut set theory. However, there was no element of optimization which can help to achieve the optimal solution. This paper presents the power tracing monitoring during voltage stability improvement process, implemented by optimal reactive power dispatch. In this study, the impact of power tracing on voltage stability variation was investigated. Evolutionary Programming (EP) was developed and utilized to incorporate power tracing, along with voltage stability improvement. A pre-developed scalar voltage stability index was incorporated to indicate the voltage stability condition. On the other hand, the voltage stability initiative was conducted via the optimal reactive power dispatch. The power tracing was monitored for both; the pre-optimization and post-optimization scenarios. Small system model was tested to realize the power tracing phenomenon, which is rather rare study in power system community. Results on power tracing obtained during the pre- and post-optimal reactive power dispatch revealed that not all generators will involve in the contribution on the total transmission loss in the system. This can be beneficial to power system operators for allocating the cost without discrimination in the long run.   


10.14311/986 ◽  
2007 ◽  
Vol 47 (4-5) ◽  
Author(s):  
E. V. Mgaya ◽  
Z. Müller

This paper deals with the general problem of utilizing of renewable energy sources to generate electric energy. Recent advances in renewable energy power generation technologies, e.g., wind and photovoltaic (PV) technologies, have led to increased interest in the application of these generation devices as distributed generation (DG) units. This paper presents the results of an investigation into possible improvements in the system voltage profile and reduction of system losses when adding wind power DG (wind-DG) to a distribution system. Simulation results are given for a case study, and these show that properly sized wind DGs, placed at carefully selected sites near key distribution substations, could be very effective in improving the distribution system voltage profile and reducing power losses, and hence could  improve the effective capacity of the system. 


Author(s):  
M. J. Tahir ◽  
Badri. A. Bakar ◽  
M. Alam ◽  
M. S. Mazlihum

<p>Mostly loads are inductive in nature in content of distribution side for any power system. Due to which system faces high power losses, voltage drop and reduction in system power factor. Capacitor placement is a common method to improve these factors. To maximize the reduction of inductive load impact, optimal capacitor placement (OCP) is necessary with the objective function of system cost minimization for voltage profile enhancement, power factor improvement and power losses minimization. As OCP is a non-linear problem with equality and inequality limitations, so the stated objective depends upon he placement and sizes of the capacitor banks. Electrical transient analyzer program (ETAP) software is used for the evaluation and modelling the power systems and genetic algorithm (GA) is used as an optimization technique for the minimization of the objective function. In this paper, to show the effectiveness of the technique IEEE 4bus,33bus system and NTDC 220KV real time grid system is modelled and evaluated in terms of objective minimization i-e maximum cost saving of the power system</p>


Author(s):  
Mohammed Hamouda Ali ◽  
Mohammed Mehanna ◽  
Elsaied Othman

The impact of the renewable distributed generations (RDGs), such as photovoltaic (PV) and wind turbine (WT) systems can be positive or negative on the system, based on the location and size of the DG. So, the correct location and size of DG in the distribution network remain an obstacle to achieving their full possible benefits. Therefore, the future distribution networks with the high penetration of DG power must be planned and operated to improve their efficiency. Thus, this paper presents a new methodology for integrated of renewable energy-based DG units with electrical distribution network. Since the main objective of the proposed methodology is to reduce the power losses and improve the voltage profile of the radial distribution system (RDS). In this regard, the optimization problem was formulated using loss sensitivity factor (LSF), simulated annealing (SA), particle swarm optimization (PSO) and a combination of loss sensitivity index (LSI) with SA & PSO (LSISA, LSIPSO) respectively. This paper contributes a new methodology SAPSO, which prevents the defects of SA & PSO. Optimal placement and sizing of renewable energy-based DG tested on 33-bus system. The results demonstrate the reliability and robustness of the proposed SAPSO algorithm to find the near-optimal position and size of the DG units to mitigate the power losses and improve the radial distribution system's voltage profile.


2017 ◽  
Vol 26 (4) ◽  
pp. 81
Author(s):  
Manju Aggarwal ◽  
Madhusudan Singh ◽  
S.K. Gupta

In a low voltage distribution system with integrated wind plant, voltage stability is impacted by the large variation of load and wind penetration. The compensators like SVC and DSTATCOM are currently being used to address such issue of voltage instability. This paper analyses the impact of wind penetration and variation of active and reactive power of the load on voltage profile of a wind generation system with and without DSTATCOM. It also analyses the performance of the system during fault by calculating various parameters of the system. It has been demonstrated that voltage stability margin increases using DSTATCOM at different wind penetration levels. This system has been simulated and analysed in MATLAB 2011b using a power system toolbox under steady state and transient conditions.


Energies ◽  
2020 ◽  
Vol 13 (12) ◽  
pp. 3219 ◽  
Author(s):  
Martin Ćalasan ◽  
Tatjana Konjić ◽  
Katarina Kecojević ◽  
Lazar Nikitović

In the current age, power systems contain many modern elements, one example being Flexible AC Transmission System (FACTS) devices, which play an important role in enhancing the static and dynamic performance of the systems. However, due to the high costs of FACTS devices, the location, type, and value of the reactive power of these devices must be optimized to maximize their resulting benefits. In this paper, the problem of optimal power flow for the minimization of power losses is considered for a power system with or without a FACTS controller, such as a Static Var Compensator (SVC) device The impact of location and SVC reactive power values on power system losses are considered in power systems with and without the presence of wind power. Furthermore, constant and variable load are considered. The mentioned investigation is realized on both IEEE 9 and IEEE 30 test bus systems. Optimal SVC allocation are performed in program GAMS using CONOPT solver. For constant load data, the obtained results of an optimal SVC allocation and the minimal value of power losses are compared with known solutions from the literature. It is shown that the CONOPT solver is useful for finding the optimal location of SVC devices in a power system with or without the presence of wind energy. The comparison of results obtained using CONOPT solver and four metaheuristic method for minimization of power system losses are also investigated and presented.


2019 ◽  
Vol 8 (4) ◽  
pp. 3881-3888

: Inclusion of Distributed Generation in the power system facilitates many features like voltage profile correction, improvement of power factor, network reliability, loadability enhancement that improve the performance of the system. Vast increase in the energy requirements to cope up with emerging trends in the community, all types of loads like residential, commercial, Industrial etc demands network up gradation. The urgency of network restructuring may be differed by an appropriate deployment of Distributed Generation in the system. Whereas, it is found that improper allocation of DGs may also degrade the system performance due to increased power losses, declined voltage profile etc. Thus, now a day’s network operators are paying wide attention towards appropriate DG allocation. This paper introduces a Modified Transmission Parameters Method considering the loss minimization as a constraint, for Siting and Sizing the Distributed Generator (DG) for installation in Distribution System based on Two Port Transmission Equations. It demonstrates an implication of Distributed Generator in power system to attain the enhanced system loadability. It also analyses the number of buses swept up from the competition of being an optimal location for DG allocation. Thus, it can be said that the proposed method facilitates enhanced ability of the system to sustain load expansion without network upgrades along with evaluation reduced candidate locations for DG installation called as ‘Inapt Locations’.


Distributed generation system penetration in the existing distribution system is done for minimizing the losses and improving the voltage profile. There are total five types of distributed generation systems exist based on their power delivery like distributed generation system injecting real and reactive power, supplying real power only, supplying reactive power only, absorbing reactive power only , supplying real power and absorbing reactive power. All these five types of distributed generation systems have different penetration effects on the radial distribution system. We get different voltage profiles and power losses for different types of distributed generation systems. The testing of these five types of distributed generation systems will be done on IEEE 33 bus radial distribution system. For computing, the line parameters and power losses of the above testing system the forward-backward sweep load flow method will be applied


Sign in / Sign up

Export Citation Format

Share Document