scholarly journals Effectiveness of Truss Supporting During Replacement of Damaged Column in a High-Rise Frame Structure Building

Author(s):  
Md. Kamrul Hassan ◽  
Md. Rabiul Alam ◽  
A.B.M. Amrul Kaish ◽  
Muhammad Fauzi Mohd Zain
2010 ◽  
Vol 163-167 ◽  
pp. 2613-2617
Author(s):  
Hai Liang Wang ◽  
Tong Wei Gao

According to the 33 floors high building, blasting vibration monitoring had been carried on. The building, along Yunnan road tunnel of Qingdao Cross-harbor Tunnel Guide Line Project, has concrete frame structure. Monitoring data had been analyzed. Results showed that rules of vertical vibration velocity and main vibration frequency have similar relevance. Amplification effect of them was existed on the middle and top of the building. From the 2nd floor of downward ground to ground, the value of them suddenly decreased. Main vibration frequency is in the range of 101~102 order of magnitude.


2011 ◽  
Vol 374-377 ◽  
pp. 1690-1693
Author(s):  
Da Chuan Chen ◽  
Ri Xin Liu ◽  
Deng Ke Li

The bottom-frame structure is a kind of small bay masonry structure building with large bay RC frame in bottom[1], it is widely exists near streets in China because of the economy and applicability. But for the poor correspondence capacity for foundation’s deformation, it is easily be damaged for this kind of building in uneven settlement. It can provides theoretical support for design and strengthening works of such kind of structure buildings by analyzing the relation between superstructure’s stiffness and settlement of foundations, which has practical significance. For the complexity of stress of the composite structure, ANSYS is used in this analysis. A strengthening project based on this theory is introduced in the end, it validates the feasibility of the conclusion.


2012 ◽  
Vol 568 ◽  
pp. 85-88
Author(s):  
Ming Gao

In 5·12 Wenchuan earthquake, most of the buildings were damaged at different degrees in Mianyang. To analysis seismic damage of RC frame structure building, and investigate its reinforcement situation,the results show that: For destruction of frame column or bottom frame structure column, enlarge section method is used mostly for reinforcement in civil engineering;To serious damage of affiliated structure such as filler wall and Parapet, most of them will be demolished and built again, and add constructional column; To the situation of concrete bottom plate with crack, paste carbon fiber sheet or bottom plant steel was used depending on the structural damage degree, and jet concrete for strengthening.


2013 ◽  
Vol 19 (6) ◽  
pp. 811-822 ◽  
Author(s):  
Mohammed Jameel ◽  
A. B. M. Saiful Islam ◽  
Mohammed Khaleel ◽  
Aslam Amirahmad

A multi-storey building is habitually modelled as a frame structure which neglects the shear wall/slab openings along with the inclusion of staircases. Furthermore, the structural strength provided by shear walls and slabs is not precisely incorporated. With increasing building height, the effect of lateral loads on a high-rise structure increases substantially. Inclusion of shear walls and slabs with the frame leads to improved lateral stiffness. Besides, their openings may play imperative role in the structural behaviour of such buildings. In this study, 61 multi-storey building configurations have been modelled. Corresponding analyses are performed to cope with the influence of shear walls, slabs, wall openings, masonry walls and staircases in addition to frame modelling. The finite element approach is used in modelling and analysis. Structural responses in each elemental combination are evaluated through equivalent static and free vibration analyses. The assessment reveals that inclusion of only slab components with frame modelling contributes trivial improvement on structural performance. Conversely, the presence of shear wall slabs with frame improves the performance noticeably. Increasing wall openings decreases the structural responses. Furthermore, it is not recommended to model staircases in addition to frame–slab–shear wall modelling, unless the effect of wall openings and slab openings is adequately considered.