scholarly journals Evaluation of ceramic flexural strength of a cobalt-chromium alloy subjected to airborne particle abrasion and tungsten inert gas welding

2019 ◽  
Vol 18 ◽  
pp. e191443
Author(s):  
Laise Pena Braga Monteiro ◽  
Issae Sousa Sano ◽  
Suelen Reis Cunha ◽  
Eliza Burlamaqui Klautau ◽  
Bruno Pereira Alves

Aim: The aim of this study was to evaluate the influence of tungsten inert gas (TIG) welding and airborne particle abrasion using aluminum oxide particles on the flexural strength of a joint between ceramic and cobalt-chromium alloys. Methods: The specimens were cast and welded using TIG, then divided into 6 groups (n = 10) and subjected to blasting with 250 μm, 100 μm, and 50 μm aluminum oxide particles. Ceramic systems were applied to the central part of all specimens. A three-point bending test using a velocity of 0.5 mm/m was performed on the specimens to measure flexural strength. Data were analyzed using two-way analysis of variance and Tukey’s test. Results: TIG welding demonstrated the lowest resistance compared with the non-welded groups. Airborne particle abrasion using 250 μm aluminum oxide particles demonstrated greater resistance in the welded groups (p < 0.05). Mixed faults were found in all specimens. Conclusion: TIG welding decreased the bond strength, and the particle size of aluminum oxide did not affect the metal-ceramic bond in groups without TIG welding.

2017 ◽  
Vol 16 ◽  
pp. 1-9
Author(s):  
Adaias Oliveira Matos ◽  
Cristiane de Castro Castelo Branco ◽  
Eliza Burlamaqui Klautau ◽  
Bruno Pereira Alves

The purpose of the present study was to evaluate the flexural strength of specimens made of nickel-chromium (Ni-Cr) and cobalt-chromium (Co-Cr) alloys and joined by tungsten inert gas (TIG) welding and conventional brazing. Ni–Cr and Co–Cr base metal specimens (n = 40, each) were cast and welded by TIG or brazing. The specimens were divided into six groups (2 base metals, four welded specimens). Ceramic systems were applied to the central part of all the specimens. A three-point bending test with a velocity of 0.5 mm/m was performed on the specimens up to the point of the first ceramic bond failure by measuring the flexural strength. Data were analyzed using two-way ANOVA and Bonferroni’s tests. Conventional welding showed the lowest flexural strength results for both alloys, while the TIG weld and the control group presented with varying bond strengths for the alloys studied. We concluded that TIG welding was superior to the conventional welding method for both Ni–Cr and Co–Cr alloys with regard to the flexural strength of the ceramic.


2011 ◽  
Vol 20 (7) ◽  
pp. 553-560 ◽  
Author(s):  
Luis Gustavo Oliveira de Vasconcellos ◽  
Lucas H. Silva ◽  
Luana Marotta Reis de Vasconcellos ◽  
Ivan Balducci ◽  
Fernando E. Takahashi ◽  
...  

2007 ◽  
Vol 64 (4) ◽  
pp. 241-245 ◽  
Author(s):  
Nemanja Mirkovic

Background/Aim. Metal-ceramic bond strength and alloys' elastic modulus clearly determine the potential of alloy application, because the ceramic integrity during mastication depends on these two characteristics. The aim of this study was to evaluate metal-ceramic bond strength and elastic modulus of cobalt-chromium alloys in making porcelainfused- to-metal restorations, regarding the application of the most frequent nickel-chromium alloy. Methods. The research was performed as an experimental study. Six metalceramic samples were made from nickel-chromium alloy (Wiron 99) and cobalt-chromium alloy (Wirobond C), according to the manufactures manuals and instructions from ISO 9693: 1996. Three-point bending test was performed up to the ceramic fracture. The fracture load was measured on an universal testing machine (Zwick, type 1464), with cross-head speed of 0,05mm/min. Results. The results of this study confirmed the significant differences between the metal-ceramic bond strength (p < 0.01) and elastic modulus (p < 0.001) of nickel-chromium and cobalt-chromium alloys, where cobalt-chromium alloys showed higher values for both tested parameters. Conclusion. Cobalt-chromium metal-ceramic alloys can successfully replace nickel-chromium alloys, especially for fabrication of long-span metal-ceramic bridges due to the great flexural strength.


2007 ◽  
Vol 64 (7) ◽  
pp. 469-473 ◽  
Author(s):  
Nemanja Mirkovic

Background/Aim. Elastic modulus of metal-ceramic systems determines their flexural strength and prevents damages on ceramics during mastication. Recycling of basic alloys is often a clinical practice, despite the possible effects on the quality of the future metal-ceramic dentures. This research was done to establish recasting effects of nickel-chromium and cobalt-chromium alloys on the elastic modulus of metalceramic systems in making fixed partial dentures. Methods. The research was performed as an experimental study. Six metal-ceramic samples of nickel-chromium alloy (Wiron 99) and cobalt-chromium alloy (Wirobond C) were made. Alloy residues were recycled through twelve casting generations with the addition of 50% of new alloy on the occasion of every recasting. Three- point bending test was used to determine elastic modulus, recommended by the standard ISO 9693:1999. Fracture load for damaging ceramic layer was recorded on the universal testing machine (Zwick, type 1464), with the speed of 0,05 mm/min. Results. The results of this research revealed significant differences between elasticity modules of metal-ceramic samples in every examined recycle generation. Recasting had negative effect on the elastic modulus of the examined alloys. This research showed the slight linear reduction of elastic modulus up to the 6th generation of recycling. After the 6th recycling there was a sudden fall of elastic modulus. Conclusion. Recasting of nickelchromium and cobalt-chromium alloys is not recommended because of the reduced elastic modulus of these alloys. Instead of reusing previously recasted alloys, the alloy residues should be returned to the manufacturer. .


2017 ◽  
Vol 18 (9) ◽  
pp. 837-841
Author(s):  
T Meenakshi ◽  
Munagapati Bharathi ◽  
Jayasree Komala

ABSTRACT Aim The aim of this study was to evaluate the effect of recasting base metal alloy on the metal–ceramic bond strength. Materials and methods A total of 60 test samples were prepared from new and recast nickel–chromium alloy and divided into six groups. In group A0, test samples were prepared from 100% new alloy. Groups A1, A2, A3, A4, and A5 were prepared from 50% new alloy and 50% casting remnants (sprue and buttons) of the previous group by weight. All these samples were coated with ceramic (IPS d.SIGN and Ivoclar-Vivadent), and samples were then subjected to three-point bending test to evaluate metal–ceramic bond strength. Results The values were analyzed using one-way analysis of variance and Tukey's post hoc test. The mean bond strength of group A0 was higher than that of groups A1, A2, A3, A4, and A5. Conclusion Metal–ceramic bond strength decreased significantly with multiple recastings. Clinical significance Bond strength between metal and ceramic is a crucial factor for the clinical performance of metal–ceramic restorations. Recasting of alloys may affect the metal oxide layer composition and thickness of metal–ceramic interface, and thereby the metal–ceramic bond. How to cite this article Meenakshi T, Bharathi M, Komala J. Evaluation of the Effect of recasting Nickel–chromium Base Metal Alloy on the Metal–ceramic Bond Strength: An in vitro Study. J Contemp Dent Pract 2017;18(9):837-841.


2010 ◽  
Vol 19 (6) ◽  
pp. 471-477 ◽  
Author(s):  
Luis Gustavo Oliveira De Vasconcellos ◽  
Leonardo Buso ◽  
Geraldo H. L. Lombardo ◽  
Rodrigo O. A. Souza ◽  
Lafayette Nogueira Júnior ◽  
...  

Molecules ◽  
2021 ◽  
Vol 26 (11) ◽  
pp. 3090
Author(s):  
Anita Ptiček Siročić ◽  
Ana Rešček ◽  
Zvonimir Katančić ◽  
Zlata Hrnjak-Murgić

The studied samples were prepared from polyethylene (PE) polymer which was coated with modified polycaprolactone (PCL) film in order to obtain bilayer films. Thin PCL film was modified with casein/aluminum oxide compound to enhance vapor permeability as well as mechanical and thermal properties of PE/PCL films. Casein/aluminum oxide modifiers were used in order to achieve some functional properties of polymer film that can be used in various applications, e.g., reduction of water vapor permeability (WVTR) and good mechanical and thermal properties. Significant improvement was observed in mechanical properties, especially in tensile strength as well as in water vapor values. Samples prepared with aluminum oxide particles indicated significantly lower values up to 60%, and samples that were prepared with casein and 5% Al2O3 showed the lowest WVTR value.


2021 ◽  
pp. 152808372110003
Author(s):  
M Atta ◽  
A Abu-Sinna ◽  
S Mousa ◽  
HEM Sallam ◽  
AA Abd-Elhady

The bending test is one of the most important tests that demonstrates the advantages of functional gradient (FGM) materials, thanks to the stress gradient across the specimen depth. In this research, the flexural response of functionally graded polymeric composite material (FGM) is investigated both experimentally and numerically. Fabricated by a hand lay-up manufacturing technique, the unidirectional glass fiber reinforced epoxy composite composed of ten layers is used in the present investigation. A 3-D finite element simulation is used to predict the flexural strength based on Hashin’s failure criterion. To produce ten layers of FGM beams with different patterns, the fiber volume fraction ( Vf%) ranges from 10% to 50%. A comparison between FGM beams and conventional composite beams having the same average Vf% is made. The experimental results show that the failure of the FGM beams under three points bending loading (3PB) test is initiated from the tensioned layers, and spread to the upper layer. The spreading is followed by delamination accompanied by shear failures. Finally, the FGM beams fail due to crushing in the compression zone. Furthermore, the delamination failure between the layers has a major effect on the rapidity of the final failure of the FGM beams. The present numerical results show that the gradient pattern of FGM beams is a critical parameter for improving their flexural behavior. Otherwise, Vf% of the outer layers of the FGM beams, i.e. Vf% = 30, 40, or 50%, is responsible for improving their flexural strength.


Sign in / Sign up

Export Citation Format

Share Document