scholarly journals BCL-xL is Correlated With Disease Severity in Neonatal Infants With Sepsis

Author(s):  
Wenshen Wu ◽  
Qi Peng ◽  
Tianli Huang ◽  
Jinfen Liao ◽  
Ning Li

Abstract Objective: to investigate the association between disease severity in patients with sepsis and TNF-a, B cell lymphoma-extra-large (BCL-xL), and serum Mitochondrial membrane potential (MMP). Methods: we investigated the correlation between SNAP-II score and levels of TNF-α, BCL-xL, and MMP-index, respectively. The receiver-operating characteristics (ROC) was to assess the diagnostic value of the the Bcl - xL in the diagnosis of the of septic shock. Results: A total of 37 children were diagnosed with sepsis. SNAP-II was positively correlated with the level of BCL-xL (r=0.450, P =0.006). The area under the BCL-xL curve was 83.0%, and the 95% CI was 67.1–93.3%. The septic shock threshold was >3.022 ng/mL, and the sensitivity and specificity were 75.0% and 95.2%, respectively. The positive predictive value was 92.3%, and the negative predictive value was 83.3%. Furthermore, the level of SNAP-II was >10, and BCL-xL was >3.022 ng/mL as the threshold, and the sensitivity, specificity, positive predictive value, and negative predictive value of septic shock were 93.8%, 95.2%, 93.8%, and 95.2%, respectively. Conclusion: A correlation has been established between SNAP II and neonatal prognosis. The combination of BCL-xL and SNAP-II was more sensitive and specific than the BCL-xL to predict neonatal sepsis outcomes.

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Wu Wenshen ◽  
Peng Qi ◽  
Huang Tianli ◽  
Liao Jinfeng ◽  
Li Ning

Abstract Background Sepsis is the most common cause of morbidity and mortality in neonatal infants. It is essential to find an accurate and sensitive biomarker to confirm and treat neonatal sepsis in order to decrease the rate of mortality. The aim of this study was to investigate the association between disease severity in patients with sepsis and TNF-α, B cell lymphoma-extra-large (BCL-xL), and serum Mitochondrial membrane potential (MMP). Methods We investigated the correlation between SNAP-II score and levels of TNF-α, BCL-xL, and MMP-index, respectively. The receiver-operating characteristics (ROC) was to assess the diagnostic value of the the Bcl-xL in the diagnosis of the of septic shock. Results A total of 37 infants were diagnosed with sepsis. SNAP-II was positively correlated with the level of BCL-xL (r = 0.450, P = 0.006). The area under the BCL-xL curve was 83.0 %, and the 95 % CI was 67.1–93.3 %. The septic shock threshold was > 3.022 ng/mL, and the sensitivity and specificity were 75.0 and 95.2 %, respectively. The positive predictive value was 92.3 %, and the negative predictive value was 83.3 %. Furthermore, the level of SNAP-II was > 10, and BCL-xL was > 3.022 ng/mL as the threshold, and the sensitivity, specificity, positive predictive value, and negative predictive value of septic shock were 93.8 %, 95.2 %, 93.8 %, and 95.2 %, respectively. Conclusions BCL-xL is associated with the progression of sepsis. The combination of BCL-xL and SNAP-II could be early predicte the severity of the disease.


2017 ◽  
Vol 29 (11) ◽  
pp. 1763-1769 ◽  
Author(s):  
Pinar Soysal ◽  
Cansu Usarel ◽  
Gul Ispirli ◽  
Ahmet Turan Isik

ABSTRACTBackground:Comprehensive neurocognitive assessment may not be performed in clinical practice, as it takes too much time and requires special training. Development of easily applicable, time-saving, and cost effective screening methods has allowed identifying the individuals that require further evaluation. The aim of present study was to assess the diagnostic value of the Attended With (AW) and Head-Turning Sign (HTS) for screening cognitive impairment (CI).Methods:Comprehensive geriatric assessment was performed in 529 elderly outpatients, and the presence or absence of AW and HTS was investigated in them all.Results:Of the 529 patients, of whom the mean age was 75.67 ± 8.29 years, 126 patients were considered as CI (102 dementia, 24 mild CI). The patients with positive AW had significantly lower scores on Mini-Mental State Examination, Cognitive State Test, and Montreal Cognitive Assessment, and activities of daily living compared to AW (−) patients (p < 0.001). Similar significant findings were obtained in the patients with positive and negative HTS (p < 0.001). The sensitivity, specificity, positive predictive value, and negative predictive value of AW in detecting CI were 92%, 37%, 31.4%, and 93.7%, respectively. The sensitivity, specificity, positive predictive value, and negative predictive value of HTS were 80%, 64%, 41.8%, and 91.5%, respectively. The area under the receiver-operating characteristics curve was 0.90 for AW and 0.82 for HTS.Conclusion:AW and HTS are fast, simple, effective, and sensitive methods for detecting CI. Therefore, they can be used for older adults attending the primary care settings with memory loss. Those with positive AW or HTS can be referred to the relevant centers for detailed cognitive assessment.


2019 ◽  
Vol 9 (2) ◽  
pp. 334-338
Author(s):  
Qing Yang ◽  
Wenhong Zhou ◽  
Jiyu Li ◽  
Guojun Wu ◽  
Feng Ding ◽  
...  

Objective: To compare the diagnostic value of shear wave elastography (SWE) and real-time elastography (RTE) in the diagnosis of benign and malignant thyroid nodules. Methods: A total of 34 patients who ever received thyroidectomy in our hospital from January 2016 to January 2018 were identified. Meanwhile, all the patients received SWE and RTE before surgery, and all the diagnoses were confirmed by pathological examinations. With respect to SWE technique, the Subject Operating Characteristics (ROC) curves were drawn, in order to obtain the optimal threshold and then make differential diagnoses of benign and malignant thyroid nodules. In terms of RTE, the Rago 5 scoring method was utilized to make differential diagnoses of benign and malignant thyroid nodules. Besides, the pathological examinations after surgery could be considered as the golden standard. At last, the sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of SWE and RTE were calculated, respectively. Results: A total of 51 thyroid nodules were identified, and 41 nodules were benign, 10 nodules were malignant. On the basis of ROC curves, with respect to SWE, the best threshold for differential diagnosis of benign and malignant thyroid nodules is 38.3 kPa. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of SWE were 72.7% (8/11), 85% (34/40), 82.4% (42/51), 68.4% (13/19), and 87.5% (35/40), respectively. And the diagnostic indicators of RTE were 81.8% (9/11), 87.5% (35/40), 84.3% (43/51), 73.7% (14/19), and 90.0% (36/40). The sensitivity of quasi-static elastography in differential diagnosis of benign and malignant thyroid nodules with diameter ≤1 cm was 87.5% (7/8), and the sensitivity of SWE was 50.0% (5/10). In addition, the accuracy of SWE in differential diagnosis of benign and malignant thyroid nodules with diameter ≥3 cm was 100% (6/6), and the accuracy of RTE for this kind of thyroid nodules was 66.7% (4/6). Conclusion: Both SWE and RTE technology have good application value in differential diagnosis of benign and malignant thyroid nodules. But, SWE is preferable when making diagnosis of benign and malignant thyroid nodules with diameter ≥3 cm, and RTE was superior in detecting benign and malignant thyroid nodules with diameter ≤1 cm.


Author(s):  
Binawati . ◽  
Prihatini . ◽  
M.Y Probohoesodo

Malaria is an endemic disease in many countries. In 103 endemic countries with around 2.5 billion population, 1−3 million death cases were reported every year. Clinical criteria and blood smear established the diagnosis of malaria. ICT (imuno chromatographytest) is needed in peripheral areas where there are no experienced laboratory technicians. The procedure is simple, practical, easy, aswell as quicker than the conventional method, and no experienced technicians are needed this ICT advantages. The aim of this study isto know the diagnostic value of Malaria Antigen Cassette with microscopic examination as the gold standard examination of malaria.This research used observational cross-sectional method This study was done in Nusa Tenggara Barat during May−June 2008. Bloodsamples were taken by finger prick in patients with Malaria symptoms: fever, chill and sweating, followed by examining the blood smearby Malaria Antigen Cassette from Focus Diagnostic. The diagnostic value was then evaluated by calculating the sensitivity, specificity,positive predictive value as well as the negative predictive value. The diagnostic value of Malaria Antigen Cassette in patients withmalaria falciparum was found as follows: sensitivity 95.2%, specificity 100%, positive predictive value 100%, and negative predictivevalue 97.6%. The diagnostic value of Malaria Antigen Cassette in patients other types than malaria falciparum was as follows: sensitivity94.8%, specificity 100%, positive predictive value 100%, and negative predictive value 95.3%. The diagnostic value of Malaria AntigenCassette was very high in diagnosing malaria falciparum compared to other types than malaria falciparum.


1970 ◽  
Vol 10 (3) ◽  
pp. 170-176
Author(s):  
AF Rabbi ◽  
RN Sarker ◽  
A Hossain

Aim: To evaluate the efficacy of transabdominal hydrosonography in the diagnosis of gastric carcinoma. Materials and Methods: Transabdominal hydrosonography of the stomach was carried out on fifty patients with clinical suspicion of gastric carcinoma. Endoscopic or peroperative biopsy was taken from pathological sites in all cases. The validity of transabdominal hydrosonography of the stomach was evaluated as compared to histopathological diagnoses. Results: The sensitivity, specificity, accuracy, positive predictive value and negative predictive value of transabdominal hydrosonography in the diagnosis of gastric carcinoma were 81.82%, 96.43%, 90.00%, 94.74% & 87.10% respectively. Conclusion: Transabdominal hydrosonography is a useful diagnostic modality for the diagnosis of gastric carcinoma. Key words: Gastric carcinoma, transabdominal hydrosonography. DOI: http://dx.doi.org/ 10.3329/bjms.v10i3.8360 BJMS 2011; 10(3): 170-176


2021 ◽  
Vol 22 (14) ◽  
pp. 7462
Author(s):  
Morgane Ducastel ◽  
Camille Chenevier-Gobeaux ◽  
Yassine Ballaa ◽  
Jean-François Meritet ◽  
Michel Brack ◽  
...  

Objective: We aimed to investigate the prognostic performances of oxidative stress (OS), inflammatory and cell activation biomarkers measured at admission in COVID-19 patients. Design: retrospective monocentric study. Setting: patients with suspected SARS-CoV-2 infection (COVID-19) admitted to the hospital. Patients: One hundred and sixty documented and unselected COVID-19-patients. Disease severity (from mild to critical) was scored according to NIH’s classification. Interventions: none. Measurements and main results: We measured OS biomarkers (thiol, advanced oxidation protein products (AOPP), ischemia-modified albumin (IMA)), inflammation biomarkers (interleukin-6 (IL-6), presepsin) and cellular activation biomarkers (calprotectin) in plasma at admission. Thiol concentrations decreased while IMA, IL-6, calprotectin and PSEP increased with disease severity in COVID-19 patients and were associated with increased O2 needs and ICU admission. The best area under the receiver-operating-characteristics curve (AUC) for the prediction of ICU admission was for thiol (AUC = 0.762). A thiol concentration <154 µmol/L was predictive for ICU admission (79.7% sensitivity, 64.6% specificity, 58.8% positive predictive value, 78.9% negative predictive value). In a stepwise logistic regression, we found that being overweight, having dyspnoea, and thiol and IL-6 plasmatic concentrations were independently associated with ICU admission. In contrast, calprotectin was the best biomarker to predict mortality (AUC = 0.792), with an optimal threshold at 24.1 mg/L (94.1% sensitivity, 64.9% specificity, 97.1% positive predictive value and 98.9% negative predictive value), and survival curves indicated that high IL-6 and calprotectin concentrations were associated with a significantly increased risk of mortality. Conclusions: Thiol measurement at admission is a promising tool to predict ICU admission in COVID-19-patients, whereas IL-6 and calprotectin measurements effectively predict mortality.


Author(s):  
Youssriah Yahia Sabri ◽  
Ikram Hamed Mahmoud ◽  
Lamis Tarek El-Gendy ◽  
Mohamed Raafat Abd El-Mageed ◽  
Sally Fouad Tadros

Abstract Background There are many causes of pleural disease including variable benign and malignant etiologies. DWI is a non-enhanced functional MRI technique that allows qualitative and quantitative characterization of tissues based on their water molecules diffusivity. The aim of this study was to evaluate the diagnostic value of DWI-MRI in detection and characterization of pleural diseases and its capability in differentiating benign from malignant pleural lesions. Results Conventional MRI was able to discriminate benign from malignant lesions by using morphological features (contour and thickness) with sensitivity 89.29%, specificity 76%, positive predictive value 89%, negative predictive value 76.92%, and accuracy 85.37%. ADC value as a quantitative parameter of DWI found that ADC values of malignant pleural diseases were significantly lower than that of benign lesions (P < 0.001). Hence, we discovered that using ADC mean value of 1.68 × 10-3 mm2/s as a cutoff value can differentiate malignant from benign pleural diseases with sensitivity 89.3%, specificity 100%, positive predictive value 100%, negative predictive value 81.2%, and accuracy 92.68% (P < 0.001). Conclusion Although DWI-MRI is unable to differentiate between malignant and benign pleural effusion, its combined morphological and functional information provide valid non-invasive method to accurately characterize pleural soft tissue diseases differentiating benign from malignant lesions with higher specificity and accuracy than conventional MRI.


Medicina ◽  
2021 ◽  
Vol 57 (5) ◽  
pp. 503
Author(s):  
Thomas F. Monaghan ◽  
Syed N. Rahman ◽  
Christina W. Agudelo ◽  
Alan J. Wein ◽  
Jason M. Lazar ◽  
...  

Sensitivity, which denotes the proportion of subjects correctly given a positive assignment out of all subjects who are actually positive for the outcome, indicates how well a test can classify subjects who truly have the outcome of interest. Specificity, which denotes the proportion of subjects correctly given a negative assignment out of all subjects who are actually negative for the outcome, indicates how well a test can classify subjects who truly do not have the outcome of interest. Positive predictive value reflects the proportion of subjects with a positive test result who truly have the outcome of interest. Negative predictive value reflects the proportion of subjects with a negative test result who truly do not have the outcome of interest. Sensitivity and specificity are inversely related, wherein one increases as the other decreases, but are generally considered stable for a given test, whereas positive and negative predictive values do inherently vary with pre-test probability (e.g., changes in population disease prevalence). This article will further detail the concepts of sensitivity, specificity, and predictive values using a recent real-world example from the medical literature.


2021 ◽  
Vol 10 (1) ◽  
pp. 20-25
Author(s):  
Sujan Shrestha ◽  
Mamen Prasad Gorhaly ◽  
Manil Ratna Bajracharya

Background Diabetic peripheral neuropathy (DPN) is a significant independent risk factor for diabetic foot, and an effective screening instrument is required to diagnose DPN early to prevent future ulceration and amputation. This study aims to determine the diagnostic accuracy of monofilament test to detect diabetic peripheral neuropathy. Methods This cross-sectional study was conducted in National Academy of Medical Sciences, Bir hospital, Mahabouddha, Kathmandu from February 2016 to January 2017. A total of 96 diabetic patients attending inpatient and outpatient Department were selected. Diabetic peripheral neuropathy was assessed by measurement of loss of protective sensation (LOPS) by monofilament test and compared with vibration perception threshold by standard biothesiometer. The sensitivity, specificity, positive predictive value and negative predictive value of monofilament test were calculated. Results The prevalence of diabetic peripheral neuropathy was 26%. The sensitivity, specificity, positive predictive value and negative predictive value of monofilament test were found to be 92.0%, 95.8%, 88.5% and 97.1% respectively. There was strong association between LOPS by monofilament and vibration perception threshold by biothesiometer. Conclusion This study showed a strong diagnostic accuracy of monofilament test to detect DPN when compared with biothesiometer. As monofilament test is a cheap, easily available, and portable, it can be used in the periphery where biothesiometer is not available.  


2021 ◽  
Vol 5 (1) ◽  
Author(s):  
Tahir Iqbal ◽  
Muhammad Usman Shahid ◽  
Ishfaq Ahmad Shad ◽  
Shahzad Karim Bhatti ◽  
Syed Amir Gilani ◽  
...  

ABSTRACT: BACKGROUND: A common surgical emergency is acute appendicitis. Various diagnostic tools are available to diagnosis acute appendicitis. Radiological investigations play an important role in making accurate and early diagnosis and thus preventing morbidity associated with the disease. OBJECTIVE: To determine the diagnostic accuracy of gray scale ultrasonography versus color Doppler in suspected cases of acute appendicitis. MATERIALS AND METHODS: The study was carried in the department of Radiology of Mayo Hospital, Lahore. A total of 75 patients were enrolled of age 18-40 years, both genders who were suspected cases of acute appendicitis. All patients underwent baseline investigations along with gray scale ultrasonography and color Doppler. All patients were subjected to surgery to confirm the diagnosis and findings were subjected to statistical analysis. RESULTS: The mean age of the patients was 23.25 ±10.55 and mean transverse diameter of appendix was 8.37 ±3.39. There were 62.7% males and 37.3%females. Findings of gray scale ultrasonography and color Doppler were then correlated with surgical findings to calculate the diagnostic accuracy of these modalities. The results revealed that gray scale ultrasonography sensitivity, specificity, positive predictive value, negative predictive value and accuracy was 92.7%, 94.32%, 95%, 91.4% and 93.3% respectively, whereas color Doppler had sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 97.7%, 93.9%, 95.3%, 97% and 96% respectively. Diagnostic accuracy of both modalities together was 98.6%. CONCLUSION: Color Doppler has better diagnostic accuracy than gray scale ultrasonography for diagnosis of acute appendicitis and the combination of both modalities yields diagnostic accuracy that is similar to gold standard.


Sign in / Sign up

Export Citation Format

Share Document