scholarly journals The Influence of SSO on the Optimization Result of Nasopharynx Carcinoma Plan

Author(s):  
Xiaolong HUA ◽  
Jianhe YU ◽  
Lu WANG ◽  
Li CHEN ◽  
Yanshu MU ◽  
...  

Abstract PurposeTo study the influence of Monaco 5.4 treatment planning system (TPS) on the dosimetry of radiotherapy for nasopharynx carcinoma (NPC) under the condition of different segment shape optimization (SSO) times.MethodsFifteen patients with T3-4N0-2M0 stage NPC were enrolled, and each case was designed with SSO of 3, 5, 7 and 10 times respectively. The dose results of the target area and the major organs at risk (OARs) were statistically analyzed by DVH statistics; moreover, the isodose lines of 70Gy, 60Gy and 54Gy were intercepted at the same plane in the transverse, coronal and sagittal views and the segment shapes were compared at the angle of 30°, 120°, 240° and 330° in beam eye view (BEV); In addition, optimization time (OT), delivery time (DT), segments# and monitor unit (MU#) were obtained and analyzed by optimization console; the plans were verified and analyzed by using ArcCheck phantom.ResultsFor target area D2, the results of the SSO7 group and the SSO10 group were similar and both better than those of SSO3 and SSO5 groups, and the D2 results of the SSO3 group were notable higher than those of the other three groups; for the major OARs, the results of the maximum dose of spinal cord, brain stem, and lens and the mean dose and V30 of parotid glands showed the same trend. It showed that SSO7 and SSO10 share similar dose results, too which are notable better than the similar dose results shared by SSO3 and SSO5; in the dose deprogram distribution of 70Gy, 60Gy and 54Gy, partial 70Gy dose spillover occurred in both groups SSO3 and SSO5 and it was more obvious in group SSO3. While there was a no significant dose spillover in group SSO7 and group SSO10; in the sub-field alignment comparison under the same angle, the alignment became more complicated and the sub-fields were smaller as the number of SSO increased; the results of segment#, MU# and plan delivery time between different SSO groups were slightly different, while the plan optimization time changed significantly. The difference between group SSO3 and group SSO10 was more than 500s; the results were compared in ArcCheck, there was no significant difference between the groups.ConclusionsThe user-defined SSO function of Monaco 5.4 TPS effectively balances the relationship between plan design efficiency and plan quality. When SSO is 7, it is better value for efficiency and quality in clinical radiotherapy for NPC.

2021 ◽  
Author(s):  
Xiaolong HUA ◽  
Jianhe YU ◽  
Lu WANG ◽  
Jiaqi DAI ◽  
Qun REN ◽  
...  

Abstract PurposeTo study the influence of Monaco 5.4 treatment planning system (TPS) on the dosimetry of radiotherapy for nasopharynx carcinoma (NPC) under the condition of different segment shape optimization (SSO) times.MethodsFifteen patients with T3-4N0-2M0 stage nasopharyngeal carcinoma were enrolled, and each case was designed with SSO of 3, 5, 7 and 10 times respectively. The dose results of the target area and the major organs at risk (OAR) were statistically analyzed by DVH statistics; moreover, the isodose lines of 70Gy, 60Gy and 54Gy were intercepted at the same plane in the transverse, coronal and sagittal views and the segment shapes were compared at the angle of 30°, 120°, 240° and 330° in beam eye view (BEV); In addition, optimization time (OT), delivery time (DT), segments# and MU# were obtained and analyzed by optimization console; the plans were verified and analyzed by using ArcCheck phantom.ResultsFor target area D2, the results of the SSO7 group and the SSO10 group were similar and both better than those of SSO3 and SSO5 groups, and the D2 results of the SSO3 group were notable higher than those of the other three groups; for the major OARs, the results of the maximum dose of spinal cord, brain stem, and lens and the mean dose and V30 of parotid glands showed the same trend. It showed that SSO7 and SSO10 share similar dose results, too which are notable better than the similar dose results shared by SSO3 and SSO5; in the dose deprogram distribution of 70Gy, 60Gy and 54Gy, partial 70Gy dose spillover occurred in both groups SSO3 and SSO5 and it was more obvious in group SSO3. While there was a no significant dose spillover in group SSO7 and group SSO10; in the sub-field alignment comparison under the same angle, the alignment became more complicated and the sub-fields were smaller as the number of SSO increased; the results of segment#, MU# and plan delivery time between different SSO groups were slightly different, while the plan optimization time changed significantly. The difference between group SSO3 and group SSO10 was more than 500s; the results were compared in ArcCheck, there was no significant difference between the groups.ConclusionsThe user-defined SSO function of Monaco 5.4 TPS effectively balances the relationship between plan design efficiency and plan quality. When SSO is 7, it is better value for efficiency and quality in clinical radiotherapy for nasopharyngeal carcinoma.


2020 ◽  
Author(s):  
Zhen Xu ◽  
Xiao-Dong Li ◽  
Lu Fu ◽  
Yong-Hua Yu

Abstract Background: To compare the difference of location by computed tomography (CT) and multiparametric magnetic resonance imaging (mpMRI) on the target delineation and volume for organs at risk (OARs) among patients with prostate cancer. Methods: T1-weighted imaging (T1WI), T2-weighted imaging (T2WI), and CT were performed among 11 patients who received radiotherapy for prostate cancer at our center between August 2018 and December 2019. The target areas were delineated using the Eclipse system, and the radiotherapy plans were made based on the treatment planning system (TPS) to compare target volume and dose-volume histogram (DVH) relative to rectum and bladder. Results: The clinical target volume (CTV) of T1WI and T2WI decreased by 18.8% (P=0.001) and 22.72% (P=0.003), respectively, compared with CT. The planning target volume (PTV) on T1WI and T2WI were 20.45% (P=0.015) and 22.31% (P= 0.008) smaller than that defined by CT. There was no significant difference in either CTV or PTV between the areas outlined on T1WI and T2WI. The DVH resulting from CT and MRI comparisons showed that the rectum and bladder dose levels were lower with MRI images compared with CT. It should be noted that at the lateral directions, the range of outlining on T2WI sequence were significantly smaller than others. Conclusion: Target planning based on mpMRI (T1WI, T2WI) is more precise than CT, which can significantly reduce the range of the target area and the volume of rectum and bladder exposed to high levels of radiation, improve the fitness and radiographic accuracy of the target area, especially on T2WI.


2020 ◽  
Vol 19 ◽  
pp. 153303382091571
Author(s):  
Yiwei Yang ◽  
Kainan Shao ◽  
Jie Zhang ◽  
Ming Chen ◽  
Yuanyuan Chen ◽  
...  

Objective: To evaluate and quantify the planning performance of automatic planning (AP) with manual planning (MP) for nasopharyngeal carcinoma in the RayStation treatment planning system (TPS). Methods: A progressive and effective design method for AP of nasopharyngeal carcinoma was realized through automated scripts in this study. A total of 30 patients with nasopharyngeal carcinoma with initial treatment was enrolled. The target coverage, conformity index (CI), homogeneity index (HI), organs at risk sparing, and the efficiency of design and execution were compared between automatic and manual volumetric modulated arc therapy (VMAT) plans. Results: The results of the 2 design methods met the clinical dose requirement. The differences in D95 between the 2 groups in PTV1 and PTV2 showed statistical significance, and the MPs are higher than APs, but the difference in absolute dose was only 0.21% and 0.16%. The results showed that the conformity index of planning target volumes (PTV1, PTV2, PTVnd and PGTVnx+rpn [PGTVnx and PGTVrpn]), homogeneity index of PGTVnx+rpn, and HI of PTVnd in APs are better than that in MPs. For organs at risk, the APs are lower than the MPs, and the difference was statistically significant ( P < .05). The manual operation time in APs was 83.21% less than that in MPs, and the computer processing time was 34.22% more. Conclusion: IronPython language designed by RayStation TPS has clinical application value in the design of automatic radiotherapy plan for nasopharyngeal carcinoma. The dose distribution of tumor target and organs at risk in the APs was similar or better than those in the MPs. The time of manual operation in the plan design showed a sharp reduction, thus significantly improving the work efficiency in clinical application.


2020 ◽  
Vol 15 (1) ◽  
Author(s):  
Wufei Cao ◽  
Yongdong Zhuang ◽  
Lixin Chen ◽  
Xiaowei Liu

Abstract Purpose In this study, we employed a gated recurrent unit (GRU)-based recurrent neural network (RNN) using dosimetric information induced by individual beam to predict the dose-volume histogram (DVH) and investigated the feasibility and usefulness of this method in biologically related models for nasopharyngeal carcinomas (NPC) treatment planning. Methods and materials One hundred patients with NPC undergoing volumetric modulated arc therapy (VMAT) between 2018 and 2019 were randomly selected for this study. All the VMAT plans were created using the Monaco treatment planning system (Elekta, Sweden) and clinically approved: > 98% of PGTVnx received the prescribed doses of 70 Gy, > 98% of PGTVnd received the prescribed doses of 66 Gy and > 98% of PCTV received 60 Gy. Of these, the data from 80 patients were used to train the GRU-RNN, and the data from the other 20 patients were used for testing. For each NPC patient, the DVHs of different organs at risk were predicted by a trained GRU-based RNN using the information given by individual conformal beams. Based on the predicted DVHs, the equivalent uniform doses (EUD) were calculated and applied as dose constraints during treatment planning optimization. The regenerated VMAT experimental plans (EPs) were evaluated by comparing them with the clinical plans (CPs). Results For the 20 test patients, the regenerated EPs guided by the GRU-RNN predictive model achieved good consistency relative to the CPs. The EPs showed better consistency in PTV dose distribution and better dose sparing for many organs at risk, and significant differences were found in the maximum/mean doses to the brainstem, brainstem PRV, spinal cord, lenses, temporal lobes, parotid glands and larynx with P-values < 0.05. On average, compared with the CPs, the maximum/mean doses to these OARs were altered by − 3.44 Gy, − 1.94 Gy, − 1.88 Gy, 0.44 Gy, 1.98 Gy, − 1.82 Gy and 2.27 Gy, respectively. In addition, significant differences were also found in brainstem and spinal cord for the dose received by 1 cc volume with 4.11 and 1.67 Gy dose reduction in EPs on average. Conclusion The GRU-RNN-based DVH prediction method was capable of accurate DVH prediction. The regenerated plans guided by the predicted EUDs were not inferior to the manual plans, had better consistency in PTVs and better dose sparing in critical OARs, indicating the usefulness and effectiveness of biologically related model in knowledge-based planning.


2019 ◽  
Vol 19 (4) ◽  
pp. 393-398 ◽  
Author(s):  
Payal Raina ◽  
Sudha Singh ◽  
Rajanigandha Tudu ◽  
Rashmi Singh ◽  
Anup Kumar

AbstractAim:The aim of this study was to compare volumetric modulated arc therapy (VMAT) with dynamic intensity-modulated radiation therapy (dIMRT) and step-and-shoot IMRT (ssIMRT) for different treatment sites.Materials and methods:Twelve patients were selected for the planning comparison study. This included three head and neck, three brain, three rectal and three cervical cancer patients. Total dose of 50 Gy was given for all the plans. Plans were done for Elekta synergy with Monaco treatment planning system. All plans were generated with 6 MV photons beam. Plan evaluation was based on the ability to meet the dose volume histogram, dose homogeneity index, conformity index and radiation delivery time, and monitor unit needs to deliver the prescribed dose.Results:The VMAT and dIMRT plans achieved the better conformity (CI98% = 0·965 ± 0·023) and (CI98% = 0·939 ± 0·01), respectively, while ssIMRT plans were slightly inferior (CI98% = 0·901 ± 0·038). The inhomogeneity in the planning target volume (PTV) was highest with ssIMRT with HI equal to 0·097 ± 0·015 when compared to VMAT with HI equal to 0·092 ± 0·0369 and 0·095 ± 0·023 with dIMRT. The integral dose is found to be inferior with VMAT 105·31 ± 53·6 (Gy L) when compared with dIMRT 110·75 ± 52·9 (Gy L) and ssIMRT 115 38 ± 55·1(Gy L). All the techniques respected the planning objective for all organs at risk. The delivery time per fraction for VMAT was much lower than dIMRT and ssIMRT.Findings:Our results indicate that dIMRT and VMAT provide better sparing of normal tissue, homogeneity and conformity than ssIMRT with reduced treatment delivery time.


2020 ◽  
Author(s):  
Wufei Cao ◽  
Yongdong Zhuang ◽  
Lixin Chen ◽  
Xiaowei Liu

Abstract Purpose: In this study, we employed a gated recurrent unit (GRU)-based recurrent neural network (RNN) using dosimetric information induced by individual beam to predict the dose-volume histogram (DVH) and investigated the feasibility and usefulness of this method in biologically related models for nasopharyngeal carcinomas (NPC) treatment planning.Methods and Materials: One hundred patients with NPC undergoing volumetric modulated arc therapy (VMAT) between 2018 and 2019 were randomly selected for this study. All the VMAT plans were created using the Monaco treatment planning system (Elekta, Sweden) and clinically approved: >98% of PGTVnx received the prescribed doses of 70 Gy, >98% of PGTVnd received the prescribed doses of 66 Gy and >98% of PCTV received 60 Gy. Of these, the data from 80 patients were used to train the GRU-RNN, and the data from the other 20 patients were used for testing. For each NPC patient, the DVHs of different organs at risk were predicted by a trained GRU-based RNN using the information given by individual conformal beams. Based on the predicted DVHs, the equivalent uniform doses (EUD) were calculated and applied as dose constraints during treatment planning optimization. The regenerated VMAT experimental plans (EPs) were evaluated by comparing them with the clinical plans (CPs).Results: For the 20 test patients, the regenerated EPs guided by the GRU-RNN predictive model achieved good consistency relative to the CPs. The EPs showed better consistency in PTV dose distribution and better dose sparing for many organs at risk, and significant differences were found in the maximum/mean doses to the brainstem, brainstem PRV, spinal cord, lenses, temporal lobes, parotid glands and larynx with P-values <0.05. On average, compared with the CPs, the maximum/mean doses to these OARs were altered by -3.44 Gy, -1.94 Gy, -1.88 Gy, 0.44 Gy, 1.98 Gy, -1.82 Gy and 2.27 Gy, respectively. In addition, significant differences were also found in brainstem and spinal cord for the dose received by 1cc volume with 4.11 and 1.67 Gy dose reduction in EPs on average.Conclusion: The GRU-RNN-based DVH prediction method was capable of accurate DVH prediction. The regenerated plans guided by the predicted EUDs were not inferior to the manual plans, had better consistency in PTVs and better dose sparing in critical OARs, indicating the usefulness and effectiveness of biologically related model in knowledge-based planning.


2021 ◽  
Author(s):  
weijun chen ◽  
Cheng Wang ◽  
Wenming Zhan ◽  
Yongshi Jia ◽  
Fangfang Ruan ◽  
...  

Abstract Background:Radiotherapy requires the target area and the organs at risk to be contoured on the CT image of the patient. During the process of organs-at-Risk (OAR) of the chest and abdomen, the doctor needs to contour at each CT image. The delineations of large and varied shapes are time-consuming and laborious.This study aims to evaluate the results of two automatic contouring software on OAR definition of CT images of lung cancer and rectal cancer patients. Methods: The CT images of 15 patients with rectal cancer and 15 patients with lung cancer were selected separately, and the organs at risk were outlined by the same experienced doctor as references, and then the same datasets were automatically contoured based on AiContour®© (Manufactured by Linking MED, China) and Raystation®© (Manufactured by Raysearch, Sweden) respectively. Overlap index (OI), Dice similarity index (DSC) and Volume difference (DV) were evaluated based on the auto-contours, and independent-sample t-test analysis is applied to the results. Results: The results of AiContour®© on OI and DSC were better than that of Raystation®© with statistical difference. There was no significant difference in DV between the results of two software. Conclusions: With AiContour®©, auto-contouring results of most organs in the chest and abdomen are good, and with slight modification, it can meet the clinical requirements for planning. With Raystation®©, auto-contouring results in most OAR is not as good as AiContour®©, and only the auto-contouring results of some organs can be used clinically after modification.


2001 ◽  
Vol 87 (2) ◽  
pp. 91-94 ◽  
Author(s):  
Carlo Capirci ◽  
Polico Cesare ◽  
Giovanni Mandoliti ◽  
Giovanni Pavanato ◽  
Marcello Gava ◽  
...  

Modern computer networks provide satisfying levels of data recording and verification between the treatment planning system (TPS) and the accelerators, while the main weakness of the preparation chain remains the simulation. When a conventional simulator is employed, it may adversely affect the three-dimensional treatment planning system (3DPS) process because of the difficulty to document the leaf positions on the simulator location films and on the patient's skin. With a conventional simulator, hard copies of the DRRs of each field and CT scans at isocenter level are needed. In an attempt to transfer more information displayed from a BEV perspective from the 3DPS to simulator radiographs, this study aimed to reduce the quality loss by using a 2D conventional simulator in a 3DPS process. We realized an acetate photocopy of TPS data for each field, from a BEV perspective, containing: DRR, wire frames of the PTV, organs at risk and MLC aperture. The photocopies, with an appropriate magnification factor to obtain a correct projective value (ratio 1:1) at isocenter level, are carefully placed on the radiographic images on the same hard copy which allows us to better understand possible setup errors and obliges us to correct these. The method provides reliable documentation, facilitates treatment verification, and fulfils the criteria for MLC simulation. It is accurate, simple, and very inexpensive.


2018 ◽  
Vol 22 ◽  
pp. 01049 ◽  
Author(s):  
Yonca Yahşi Çelen ◽  
Atilla Evcin

It is aimed to compare the values of conformity index (CI), homogeneity index (HI), monitor unit (MU) of volumetrically adjusted arthritis therapy (VMAT) plans using 10 prostate cancer patients with flattened filter (FF) and without flattening filter (FFF). In the study, treatment plans were prepared using 6 FF and 6 FFF in the Eclipse (ver.13.6) treatment planning system with Varian Trilogy Linear Accelerator. When planning was completed, CI averaged 0.87, HI averaged 0.44 and MU values were found to be 591 ± 26.8, 650 ± 33.06, respectively. When the PTV coverage, CI, HI and MU comparisons were made as a result of planning, there was no significant difference when comparing VMAT plans in FFF and FF energies. When we compare the MU values, the MU increase is seen when the straightening filter is removed. In both energy modes, good homogeneity in PTV was achieved with conventional francitation and close dose rates. No significant advantages and disadvantages of the unfiltered energy mode were observed in the assessment of plan quality in terms of CI, HI.


2019 ◽  
Vol 14 (1) ◽  
Author(s):  
You Zhang ◽  
Tsuicheng Chiu ◽  
Jeffrey Dubas ◽  
Zhen Tian ◽  
Pam Lee ◽  
...  

Abstract Introduction Stereotactic body radiation therapy (SBRT) was found effective in treating laryngeal cancer with only five treatment fractions by a recent clinical trial (NCT01984502, ClinicalTrials.gov). Nevertheless, this trial used the Cyberknife system, which is not widely accessible enough to benefit all patients affected by laryngeal cancer. Our study investigates the feasibility of larynx SBRT treatment planning on a conventional gantry-based LINAC and compares its plan quality with that from the Cyberknife. Materials & methods Ten larynx SBRT cases were originally treated by Cyberknife using fixed cones in our institution, with plans created and optimized using the Monte-Carlo algorithm in the MultiPlan treatment planning system. These cases were retrospectively planned in the Eclipse planning system for a LINAC with the same prescription dose. We used volumetric modulated arc therapy (VMAT) for larynx SBRT planning in Eclipse and incorporated non-coplanar arcs to approach the Cyberknife’s large solid angle delivery space. We used both anisotropic analytical algorithm (AAA) and Acuros XB (AXB) algorithm for dose calculation and compared their accuracy by measurements on an in-house larynx phantom. We compared the LINAC VMAT plans (VMAT-AAA and VMAT-AXB) with the original Cyberknife plans using dosimetric endpoints such as the conformity index, gradient indices (R50, R20), OAR maximum/mean doses, and the monitor units. Results Phantom measurement showed that both the AAA and the AXB algorithms provided adequate dose calculation accuracy (94.7% gamma pass rate on 2%/2 mm criteria for AAA vs. 97.3% for AXB), though AXB provided better accuracy in the air cavity. The LINAC-based VMAT plans achieved similar dosimetric endpoints as the Cyberknife planning, and all plans met the larynx SBRT dosimetric constraints. Cyberknife plans achieved an average conformity index of 1.13, compared to 1.20 of VMAT-AXB and 1.19 of VMAT-AAA. The VMAT plans spared the thyroid gland better with average Dmean of 2.4 Gy (VMAT-AXB) and 2.7 Gy (VMAT-AAA), as compared to 4.3 Gy for Cyberknife plans. The VMAT-AAA plans had a slightly lower contralateral arytenoid Dmax (average: 15.2 Gy) than Cyberknife plans (average: 17.9 Gy) with statistical significance, while the contralateral arytenoid Dmax was similar between VMAT-AXB and Cyberknife plans with no statistically significant difference. Cyberknife plans offered slightly better R50 (average: 5.0) than VMAT-AXB (5.9) and VMAT-AAA (5.7) plans. The VMAT plans substantially reduced the plan MUs to less than 1/3 of the Cyberknife plans, and the differences were statistically significant. The other metrics were similar between VMAT and Cyberknife plans with no statistically significant differences. Conclusions Gantry-based LINACs can achieve similar plan quality to Cyberknife systems. Treatment outcome with both methods remains to be investigated.