scholarly journals Lighting system based on converting emission area by light guide

2002 ◽  
Vol 86 (Appendix) ◽  
pp. 248-248
Author(s):  
Motohiko Matsushita ◽  
Akihiro Funamoto ◽  
Motoaki Takaoka ◽  
Shigeru Aoyama
2012 ◽  
Vol 461 ◽  
pp. 521-525
Author(s):  
Jing Feng Xu ◽  
De Xin Zong ◽  
Yi Hua Yin

As a new lighting technology, light guide lighting technology has been paid more attention and applied in the indoor lighting widely. However, it is rarely applied to tunnel lighting recently. This paper analyzes the characteristics of light guide lighting system and tunnel lighting, and discusses the feasibility of application of light guide lighting technology in tunnel lighting. Finally, it proposes some light guide lighting technologies suitable for tunnel lighting, and provides the ideas and references to application and promotion of light guide lighting technology in tunnel lighting in the future.


2013 ◽  
Vol 353-356 ◽  
pp. 3089-3092
Author(s):  
Wei Li ◽  
Guang Ke Zhao ◽  
Yan Ling Na

In this paper, a special lighting system that uses seamless prism light guide as main lighting component and application of the system in a high-humidity room is introduced. Experimental results show that the illuminance level and uniformity in the room has been improved greatly by the application of the guide. The average horizontal and vertical illuminance on main working plan created by the seamless light guide system is individually 74.1% and 101.8% higher than that created by the original lighting fixtures. The application of the seamless light guide system also makes the maintaining work become easier and safer.


Author(s):  
M. Hibino ◽  
K. Irie ◽  
R. Autrata ◽  
P. schauer

Although powdered phosphor screens are usually used for scintillators of STEM, it has been found that the phosphor screen of appropriate thickness should be used depending on the accelerating voltage, in order to keep high detective quantum efficiency. 1 It has been also found that the variation in sensitivity, due to granularity of phosphor screens, makes the measurement of fine electron probe difficult and that the sensitivity reduces with electron irradiation specially at high voltages.In order to find out a preferable scintillator for STEM, single crystals of YAG (yttrium aluminum garnet), which are used for detecting secondary and backscattered electrons in SEM were investigated and compared with powdered phosphor screens, at the accelerating voltages of 100kV and 1 MV. A conventional electron detection system, consisting of scintillator, light guide and PMT (Hamamatsu Photonics R268) was used for measurements. Scintillators used are YAG single crystals of 1.0 to 3.2mm thicknesses (with surfaces matted for good interface to the light guide) and of 0.8mm thickness (with polished surface), and powdered P-46 phosphor screens of 0.07mm and 1.0mm thicknesses for 100kV and 1MV, respectively. Surfaces on electron-incidence side of all scintillators are coated with reflecting layers.


2020 ◽  
pp. 87-97
Author(s):  
Sourish Chatterjee ◽  
Biswanath Roy

In an office space, an LED-based lighting system allows you to perform the function of a data transmitter. This article discusses the cost-effective design and development of a data-enabled LED driver that can transmit data along with its receiving part. In addition, this paper clearly outlines the application of the proposed VLC system in an office environment where ambient light interference is a severe issue of concern. The result shows satisfactory lighting characteristics in general for this area in terms of average horizontal illuminance and illuminance uniformity. At the same time, to evaluate real-time and static communication performance, Arduino interfaced MATLAB Simulink model is developed, which shows good communication performance in terms of BER (10–7) even in presence of ambient light noise with 6 dB signal to interference plus noise ratio. Our designed system is also flexible to work as a standalone lighting system, whenever data communication is not required.


2019 ◽  
pp. 108-114
Author(s):  
Nicolay R. Vorobyov

Architectural and artistic construction of museum is one of the most complex genres in environment development and design, with its inherent qualities, means of expressiveness, principles of environment and image development, scientific concepts, in the context of historical development, artistic styles and trends. The author of the article considers the artistic lighting design in isolation from the integral dramaturgy of the project to be deeply flawed, and the setting of accent lighting at the final stage Ц to be simple, but not outstanding. Based on extensive hands-on experience in the construction of museum expositions, the author of the article reveals some peculiarities, especially significant to the participants of the lighting system setting for museums and other cultural facilities.


2019 ◽  
pp. 15-21
Author(s):  
Banu Manav

In lighting design, the main concept is to achieve a healthy environment, which addresses energy efficiency, cost, maintenance, and quality. User-friendly lighting systems shall be adopted to architecture and interior architecture. User control over the lighting system is important, by dimming or increasing light output, by changing the colour of the light sets the inner atmosphere and affects user mood. Standards and codes on lighting shall also be evaluated by means of these topics. The paper aims to analyse how the luminous environment is affective on the perceived environment. Hence, a series of experimental studies and recent research will be evaluated in regard to understanding and designing luminous environment.


2018 ◽  
pp. 156-161
Author(s):  
Alexei K. Solovyov

Underground spaces in town centres present a big attraction for investors. However, they put special requirements to the internal environment. Those requirements can be fulfilled by means of daylighting. Examples of lighting of underground spaces are discussed. It is shown that the common systems of natural lighting are not always possible to use and cause big heat losses. Hollow light guide pipes allow avoid the shortcomings of common daylight systems. Method of calculation of daylight factors from hollow light guide pipes is shown. The results of calculation of daylight factors under the light guide pipes of different diameters in the different depths are presented.


Author(s):  
Chun Yin ◽  
Sara Dadras ◽  
Yuhua Cheng ◽  
Xuegang Huang ◽  
Kai Chen ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document