scholarly journals Effect of Cortical Bone Thickness on Detection of Intraosseous Lesions by Ultrasonography

2015 ◽  
Vol 2015 ◽  
pp. 1-6 ◽  
Author(s):  
Sadaf Adibi ◽  
Alireza Shakibafard ◽  
Zohreh Karimi Sarvestani ◽  
Najmeh Saadat ◽  
Leila Khojastepour

Background. Usefulness of ultrasound (US) in detection of intrabony lesions has been showed. A cortical bone perforation or a very thin and intact cortical bone is prerequisite for this purpose.Objective. The current in vitro study was aimed at measuring the cut-off thickness of the overlying cortical bone which allows ultrasonic assessment of bony defects.Materials and Methods. 20 bovine scapula blocks were obtained. Samples were numbered from 1 to 20. In each sample, 5 artificial lesions were made. The lesions were made in order to increase the overlying bone thickness, from 0.1 mm in the first sample to 2 mm in the last one (with 0.1 mm interval). After that, the samples underwent ultrasound examinations by two practicing radiologists.Results. All five lesions in samples numbered 1 to 11 were detected as hypoechoic area. Cortical bone thickness more than 1.1 mm resulted in a failure in the detection of central lesions.Conclusion. We can conclude that neither bony perforation nor very thin cortical bones are needed to consider US to be an effective imaging technique in the evaluation of bony lesion.

2008 ◽  
Vol 55 (10) ◽  
pp. 2191-2197 ◽  
Author(s):  
Janne Karjalainen ◽  
Ossi Riekkinen ◽  
Juha Toyras ◽  
Heikki Kroger ◽  
Jukka Jurvelin

2007 ◽  
Vol 33 (2) ◽  
pp. 254-262 ◽  
Author(s):  
Petro Moilanen ◽  
Patrick H.F. Nicholson ◽  
Vantte Kilappa ◽  
Sulin Cheng ◽  
Jussi Timonen

Materials ◽  
2020 ◽  
Vol 13 (21) ◽  
pp. 4789
Author(s):  
Adelina Popa ◽  
Cristina Dehelean ◽  
Horia Calniceanu ◽  
Claudia Watz ◽  
Silviu Brad ◽  
...  

Background: Orthodontic mini-implant failure is a debatable subject in clinical practice. However, the most important parameter to evaluate the success rate of mini-implant is the primary stability, which is mainly influenced by cortical bone thickness (CBT) and insertion angle. Materials and methods: Three-dimensional finite element models of the maxilla were created and a custom-made, self-drilling, tapered mini-implant was designed. For the pull-out test, 12 simulations were performed, sequentially increasing the thickness of the cortical bone (1, 1.5 and 2 mm) and the insertion angle (30°, 60°, 90°, 120°). For the force analysis, 24 simulations were performed using an experimental orthodontic traction force of 2 N both in the horizontal and vertical axis. Results: Insertion angle and CBT have significant impact on force reaction values (p < 0.05). Cortical bone stress had the lowest value when the mini-implant had a 30° insertion angle and the highest value when the implant had a 120° insertion angle, while the CBT was 1 mm. Cortical bone stress had the lowest value with an insertion angle of 90° and the highest value when the implant was inserted at an angle of 30°, while the CBT was 2 mm independent of the force direction. Regarding the biosafety profile of the mini-implant alloy, the present results reveal that the custom-made mini-implant presents good biocompatibility. Conclusions: When the CBT is reduced, we recommend inclined insertion while, when the CBT is appropriate, perpendicular insertion is advised.


2021 ◽  
Vol 80 (Suppl 1) ◽  
pp. 825.2-826
Author(s):  
M. Jansen ◽  
A. Ooms ◽  
T. D. Turmezei ◽  
J. W. Mackay ◽  
S. Mastbergen ◽  
...  

Background:In addition to cartilage degeneration, knee osteoarthritis (OA) causes bone changes, including cortical bone thickening, subchondral bone density decrease, and bone shape changes as a result of widening and flattening condyles and osteophyte formation. Knee joint distraction (KJD) is a joint-preserving treatment for younger (<65 years) knee OA patients that has been shown to reverse OA cartilage degradation. On radiographs, KJD showed a decrease in subchondral bone density and an increase in osteophyte formation. However, these bone changes have never been evaluated with a 3D imaging technique.Objectives:To evaluate cortical bone thickness, subchondral trabecular bone density, and bone shape on CT scans before and one year after KJD treatment.Methods:19 KJD patients were included in an extended imaging protocol, undergoing a CT scan before and one year after treatment. Stradview v6.0 was used for semi-automatic tibia and femur segmentation from axial thin-slice (0.45mm) CT scans. Cortical bone thickness (mm) and trabecular bone density (Hounsfield units, HU) were measured with an automated algorithm. Osteophytes were excluded. Afterwards, wxRegSurf v18 was used for surface registration. Registration data was used for bone shape measurements. MATLAB R2020a and the SurfStat MATLAB package were used for data analysis and visualization. Two-tailed F-tests were used to calculate changes over time. Two separate linear regression models were used to show the influence of baseline Kellgren-Lawrence grade and sex on the changes over time. Statistical significance was calculated with statistical parametric mapping; a p-value <0.05 was considered statistically significant. Bone shape changes were explored visually using vertex by vertex displacements between baseline and follow-up. Patients were separated into two groups based on whether their most affected compartment (MAC) was medial or lateral. Only patients with axial CT scans at both time points available for analysis were included for evaluation.Results:3 Patients did not have complete CTs and in 1 patient the imaged femur was too short, leaving 16 patients for tibial analyses and 15 patients for femoral analyses. The MAC was predominantly the medial side (medial MAC n=14; lateral n=2). Before treatment, the MAC cortical bone was compared to the rest of the joint (Figure 1). One year after treatment, MAC cortical thickness decreased, although this decrease of up to approximately 0.25 mm was not statistically significant. The trabecular bone density was also higher before treatment in the MAC, and a decrease was seen throughout the entire joint, although statistically significant only for small areas on mostly the MAC where this decrease was up to approximately 80 HU (Figure 1). Female patients and patients with a higher Kellgren-Lawrence grade showed a somewhat larger decrease in cortical bone thickness. Trabecular density decreased less for patients with a higher Kellgren-Lawrence grade, and female patients showed a higher density decrease interiorly while male patients showed a higher decrease exteriorly. None of this was statistically significant. The central areas of both compartments showed an outward shape change, while the outer ring showed inward changes.Conclusion:MAC cortical bone thickness shows a partial decrease after KJD. Trabecular bone density decreased on both sides of the joint, likely as a direct result of the bicompartmental unloading. For both subchondral bone parameters, MAC values became more similar to the LAC, indicating (partial) subchondral bone normalization in the most affected parts of the joint. The bone shape changes may indicate a reversal of typical OA changes, although the inward difference that was seen on the outer edges may be a result of osteophyte-related changes that might have affected the bone segmentation. In conclusion, KJD treatment shows subchondral bone normalization in the first year after treatment, and longer follow-up might show whether these changes are a temporary result of joint unloading or indicate more prolonged bone changes.Disclosure of Interests:None declared.


2007 ◽  
Vol 8 (4) ◽  
pp. 262-267 ◽  
Author(s):  
T.A. Takla ◽  
S.A. Zelenitsky ◽  
L.M. Vercaigne

Purpose This in vitro study tested the effectiveness of a novel 30% ethanol/4% trisodium citrate (TSC) lock solution against the most common pathogens causing hemodialysis catheter-related infections. Methods Clinical isolates of methicillin-resistant Staphylococcus aureus (MRSA) (n=4), methicillin-sensitive S. aureus (MSSA) (n=8), methicillin-resistant Staphylococcus epidermidis (MRSE) (n=8), Pseudomonas aeruginosa (n=4) and Escherichia coli (n=4) were tested in duplicate. Bacterial suspensions of each isolate were made in a control solution of normal saline and Mueller-Hinton broth (MHB), and in a lock solution of ethanol 30%, TSC 4% and MHB. Suspensions were incubated at 37 °C for 48 h. Colony counts were determined from samples collected at t=0 h (before exposure to the ethanol/TSC lock), t=1 h (one hour after exposure to the ethanol/TSC lock), t=24 h and t=48 h. To confirm the absence of viable organisms in the lock solution, the remaining volume at 48 h was filtered through a 0.45 μm filter. The filter was rinsed with 15 mL sterile water and plated on tryptic soy agar (TSA). Results All controls demonstrated significant growth over 48 h. In the lock solutions, initial inocula were reduced to 0 viable colonies by t=1 h (6-log kill), and there was no growth at t=24 and 48 h. Filtering of lock solutions also showed no growth. These results were consistent among duplicates of all isolates. Conclusions The 30% ethanol/4% TSC lock solution consistently eradicated MRSA, MSSA, MRSE, P. aeruginosa and E. coli within 1 h of exposure. Experiments are currently underway to test this novel lock solution on preventing biofilm production by these pathogens.


2015 ◽  
Vol 12 (2) ◽  
pp. 111-117
Author(s):  
P K Parajuli ◽  
S George ◽  
V Shenoy

Background: Dual-arch impression technique allows the simultaneous recording of  tooth preparation, opposing anatomic tooth and maxillomandibular relationship. The  accuracy of reproduction of this easy and quick technique, however, has not been  studied in detail in past. Objective: To compare the accuracy of the impressions  made by using the same impression material in dual arch plastic trays, dual-arch  metal trays and acrylic resin custom trays. Methods: The dies obtained from the  addition silicone impressions made in dual-arch plastic trays, dual-arch metal trays  and full arch acrylic resin custom trays were compared for the dimensional accuracy  with the prepared typodont tooth as a control. Student’s paired t-test and unpaired  t-test were used for the data analyses using the Statistical Package for Social Studies  (SPSS) version 11.5. Results: The dies obtained from all the impression combinations  showed increased dimension (acrylic resin custom trays 9.4 mm±0.048, dual-arch  plastic trays 9.5 mm±0.035, dual-arch metal trays 9.41 mm±0.017) as compared to  the dimension of control (9.39 mm±0.007). Conclusion: All the tray-impression  material combinations showed variable accuracies. Full arch acrylic resin trays  resulted in greatest accuracy whereas dual-arch plastic trays the least accuracy.Health Renaissance 2014;12(2):  pp: 111-117


Sign in / Sign up

Export Citation Format

Share Document