scholarly journals Environmental surveillance of Legionella pneumophila in hot water systems of hotels in Morocco

Author(s):  
Abdelwahid Assaidi ◽  
Afaf Soummane ◽  
Mostafa Ellouali ◽  
Hassan Latrache ◽  
Mohammed Timinouni ◽  
...  

Abstract Objective: Environmental monitoring of Legionella in hot water systems of hotels in Morocco was performed during the period from January 2016 to April 2018. A total of 149 water samples from 118 different hotels were analyzed. Methods: A total of 149 water samples from 118 different hotels were analyzed. Possible risk factors were prospectively recorded, and data were analyzed in connection with building and plumbing systems characteristics. Data about building and risk factors were collected through a questionnaire survey. Results: Out of the 149 samples, 77(51.7%) were positive for L. pneumophila. Serological typing of the isolates revealed that 54 (70.1%) are L. pneumophila serogroup 2–15 and 23 (29.9%) are L. pneumophila serogroup 1. 56.8% of all buildings were colonized by L. pneumophila. Counts were over 1,000 CFU/L in 44%. Contamination was strongly correlated with temperature in the circulation, the age of the premise plumbing and the size of the building. Conclusions: The results showed a relevant exposure to L. pneumophila in the community and the identified risk factors can serve as indicators for risk assessment and relevant actions.

2005 ◽  
Vol 71 (10) ◽  
pp. 5805-5813 ◽  
Author(s):  
Paola Borella ◽  
Maria Teresa Montagna ◽  
Serena Stampi ◽  
Giovanna Stancanelli ◽  
Vincenzo Romano-Spica ◽  
...  

ABSTRACT A cross-sectional multicenter survey of Italian hotels was conducted to investigate Legionella spp. contamination of hot water. Chemical parameters (hardness, free chlorine concentration, and trace element concentrations), water systems, and building characteristics were evaluated to study risk factors for colonization. The hot water systems of Italian hotels were strongly colonized by Legionella; 75% of the buildings examined and 60% of the water samples were contaminated, mainly at levels of ≥103 CFU liter−1, and Legionella pneumophila was the most frequently isolated species (87%). L. pneumophila serogroup 1 was isolated from 45.8% of the contaminated sites and from 32.5% of the hotels examined. When a multivariate logistic model was used, only hotel age was associated with contamination, but the risk factors differed depending on the contaminating species and serogroup. Soft water with higher chlorine levels and higher temperatures were associated with L. pneumophila serogroup 1 colonization, whereas the opposite was observed for serogroups 2 to 14. In conclusion, Italian hotels, particularly those located in old buildings, represent a major source of risk for Legionnaires' disease due to the high frequency of Legionella contamination, high germ concentration, and major L. pneumophila serogroup 1 colonization. The possible role of chlorine in favoring the survival of Legionella species is discussed.


1997 ◽  
Vol 25 (6) ◽  
pp. 452-457 ◽  
Author(s):  
Sue Miuetzner ◽  
Robert C. Schwille, ◽  
Adrianne Farley ◽  
Ellen R. Wald ◽  
John H. Ge ◽  
...  

Author(s):  
Ashley Heida ◽  
Alexis Mraz ◽  
Mark Hamilton ◽  
Mark Weir ◽  
Kerry A Hamilton

Legionella pneumophila are bacteria that when inhaled cause Legionnaires’ Disease (LD) and febrile illness Pontiac Fever. As of 2014, LD is the most frequent cause of waterborne disease outbreaks due...


1996 ◽  
Vol 42 (8) ◽  
pp. 811-818 ◽  
Author(s):  
Outi M. Zacheus ◽  
Pertti J. Martikainen

The decontamination of Legionella pneumophila and other heterotrophic microbes by heat flushing in four legionellae-positive hot water systems was studied. Before the decontamination procedure, the concentration of legionellae varied from 3.0 × 10−3 to 3.5 × 10−5 cfu/L and the hot water temperature from 43.6 to 51.5 °C. During the contamination the temperature was raised to 60–70 °C. All taps and showers were cleaned from sediments and flushed with hot water twice a day for several minutes. The decontamination lasted for 2–4 weeks. In a few weeks the heat-flushing method reduced the concentration of legionellae below the detection limit (50 cfu/L) in the hot circulating water system just before and after the heat exchanger. The high hot water temperature also decreased the viable counts of heterotrophic bacteria, fungi, and total microbial cells determined by the epifluorescent microscopy. However, the eradication of legionellae failed in a water system where the water temperature remained below 60 °C in some parts of the system. After the decontamination, the temperature of hot water was lowered to 55 °C. Thereafter, all the studied hot water systems were recolonized by legionellae within a few months, showing that the decontamination by heat flushing was temporary. Also, the contamination of other bacteria increased in a few months to the level before decontamination.Key words: legionellae, hot water system, decontamination, water temperature, heterotrophic bacteria.


2021 ◽  
Vol 59 (3) ◽  
Author(s):  
Daniela Glažar Ivče ◽  
Dobrica Rončević ◽  
Marina Šantić ◽  
Arijana Cenov ◽  
Dijana Tomić Linšak ◽  
...  

Research background. Legionella are Gram-negative bacteria that are ubiquitous in the natural environment. Contaminated water in manmade water systems is a potential source of transmission of Legionnaires’ disease (LD). The aim of this study was to explore the prevalence of Legionella pneumophila (L. pneumophila) in the drinking water distribution system (DWDS) of Primorje-Gorski Kotar County (PGK County), Croatia, for the period 2013-2019, coupled with the incidence of LD. A number of L. pneumophila-positive samples (>100 CFU/L), serogroup distribution, and the degree of contamination of specific facilities (health & aged care, tourism, sports) were assessed. Based on the results obtained, the reasoning for the implementation of a mandatory Legionella environmental surveillance program was assessed. Experimental approach. Sample testing for Legionella was carried out according to ISO 1173. A Heterotrophic Plate Count (HPC) and P. aeruginosa were analysed along with the basic physico-chemical indicators of drinking water quality. The research period was divided into two parts, namely, the 2013-2018 period (before implementation of the prevention program, after the outbreak of LD), and year 2019 (proactive approach, no LD cases recorded). Results and conclusion. During the 7-year observation period in PGK County, an increase in the number of samples tested for Legionella was found. An increase in Legionella-positive samples (particularly pronounced during the warmer part of the year) was recorded, along with a growing trend in the number of reported LD cases. In addition to hot water systems, the risk of Legionella colonization also applies to cold water systems. Health & aged care facilities appear to be at highest risk. In addition to the higher proportion of positive samples and a higher degree of microbiological load at these facilities, the highest proportion of L. pneumophila SGs 2-14 was identified. Due to the diagnostic limitations of the applied tests, the number of LD cases is underdiagnosed. Novelty and scientific contribution. The introduction of a mandatory preventive approach to monitoring Legionella in DWDS water samples, along with the definition of national criteria for the interpretation of results, will create the preconditions for diagnosis and adequate treatment of larger numbers of LD cases.


1999 ◽  
Vol 37 (7) ◽  
pp. 2189-2196 ◽  
Author(s):  
Paolo Visca ◽  
Paola Goldoni ◽  
P. Christian Lück ◽  
Jürgen H. Helbig ◽  
Lorena Cattani ◽  
...  

Five sporadic cases of nosocomial Legionnaires’ disease were documented from 1989 to 1997 in a hospital in northern Italy. Two of them, which occurred in a 75-year-old man suffering from ischemic cardiopathy and in an 8-year-old girl suffering from acute leukemia, had fatal outcomes. Legionella pneumophila serogroup 6 was isolated from both patients and from hot-water samples taken at different sites in the hospital. These facts led us to consider the possibility that a single clone of L. pneumophila serogroup 6 had persisted in the hospital environment for 8 years and had caused sporadic infections. Comparison of clinical and environmental strains by monoclonal subtyping, macrorestriction analysis (MRA), and arbitrarily primed PCR (AP-PCR) showed that the strains were clustered into three different epidemiological types, of which only two types caused infection. An excellent correspondence between the MRA and AP-PCR results was observed, with both techniques having high discriminatory powers. However, it was not possible to differentiate the isolates by means of ribotyping and analysis of rrnoperon polymorphism. Environmental strains that antigenically and chromosomally matched the infecting organism were present at the time of infection in hot-water samples taken from the ward where the patients had stayed. Interpretation of the temporal sequence of events on the basis of the typing results for clinical and environmental isolates enabled the identification of the ward where the patients became infected and the modes of transmission of Legionellainfection. The long-term persistence in the hot-water system of different clones of L. pneumophila serogroup 6 indicates that repeated heat-based control measures were ineffective in eradicating the organism.


2019 ◽  
Vol 8 (18) ◽  
Author(s):  
Vicente Gomez-Alvarez ◽  
Laura Boczek ◽  
Dawn King ◽  
Adin Pemberton ◽  
Stacy Pfaller ◽  
...  

Public health data show that a significant fraction of the nation’s waterborne disease outbreaks are attributable to premise plumbing. We report the draft genome sequences of seven Legionella pneumophila serogroup 1 isolates from hot water lines of a large building.