Effect of Pre-Ozonation on Removal of Organic Matter during Water Treatment Plant Operations

1993 ◽  
Vol 27 (11) ◽  
pp. 37-45 ◽  
Author(s):  
Marc Edwards ◽  
Markus Boller ◽  
Mark M. Benjamin

Pre-ozonation altered removal of organic matter during bench or full-scale water treatment through two main effects. First, pre-ozonation directly removed organic matter by mineralization, volatilization and/or stripping reactions, improving removal in comparison to unozonated systems. On the other hand, pre-ozonation decreased the surface charge of floc formed after coagulation with hydrolyzable metal salts, hindering adsorptive removal of the anionic organic molecules by floc surfaces and/or inducing stabilized floc formation; changes that decrease removal in comparison to unozonated systems. The relative importance of the two effects determined whether pre-ozonation enhanced or hindered removal of organic matter. In most water treatment plants pre-ozonation is predicted to have an adverse effect on physical removal of organic matter at ozone doses above about 0.7 mg O3/mg TOC, while enhanced removal may occur if relatively high concentrations of volatile organic matter are present. In ancillary results, pre-ozonation hindered turbidity removal and increased the concentration of coagulant metal residuals in finished drinking water at low coagulant doses.

2013 ◽  
Vol 3 (4) ◽  
pp. 549-556 ◽  
Author(s):  
Kaveh Sookhak Lari ◽  
Morteza Kargar

High-rate lamella settlers in clarifiers and triple media filters have been implemented in Isfahan water treatment plant (known as ‘Baba-Sheikh-Ali’) in Iran to upgrade existing clarification/filtration processes during the recent years. The applied technologies are mainly used to reduce finished water turbidity as the primary regional criterion on water quality. However, application of both technologies faced some operational limitations since they began to work. These problems are due to the existing layout of the process units and available materials. The current study focuses on performance of restricted application of the two technologies with respect to turbidity removal. Online measured turbidity data from a two-year field observation (since March 2010) are used. In particular, results show a more promising and long-term effect on turbidity removal due to tripling filter media rather than application of the lamella settlers in clarifiers. The reasons for these observations are discussed.


2015 ◽  
Vol 57 (20) ◽  
pp. 9061-9069
Author(s):  
Sanghyun Jeong ◽  
Tien Vinh Nguyen ◽  
Saravanamuthu Vigneswaran ◽  
Jaya Kandasamy ◽  
Dharma Dharmabalan

2017 ◽  
Vol 31 (3) ◽  
pp. 330-344 ◽  
Author(s):  
Dan Stein ◽  
Gopal Achari ◽  
Cooper H. Langford ◽  
Mohammed H. I. Dore ◽  
Husnain Haider ◽  
...  

2010 ◽  
Vol 2 (5) ◽  
pp. 5-8
Author(s):  
Ramunė Albrektienė ◽  
Mindaugas Rimeika

The article examines different methods for determining organic matter and colour in water. Most of organic compounds in water have a humic substance. These substances frequently form complexes with iron. Humic matter gives water a yellow-brownish colour. Water filtration through conventional sand filters does not remove colour and organic compounds, and therefore complicated water treatment methods shall be applied. The methods utilized for organic matter determination in water included research on total organic carbon, permanganate index and the bichromate number of UV absorption of 254 nm wave length. The obtained results showed the greatest dependence between water colour and permanganate index. However, UV adsorption could be used for organic matter determination during the operation of a water treatment plant and the start-up of plants as easy and fast methods.


2013 ◽  
Vol 448-453 ◽  
pp. 317-321 ◽  
Author(s):  
Jing Wen Cao ◽  
Shao Wei Liao ◽  
Chung Yi Chung ◽  
Hwa Sheng Gau ◽  
Chun Yen Chiu ◽  
...  

In this research, the UV absorbance values of wavelength at 210 and 254 nm, excitation emission fluorescent matrix were measured for source water and treated water in CCL (Cheng Ching Lake) water treatment plant during five months. The whole data produced from EEFM was analyzed by PARAFAC operated in MATLAB software. The variation of molecular weight for organic matter was measured by HPLC (high performance liquid chromatography) with UV and fluorescent detectors. Observed from the variation of UV210/UV254, high value in treated water compared with source water was found. More molecular weight less than 5 k Da was formed in the treated water with relative to source water. Also, both major components in source water were located at wavelengths of excitation/emission of 250/410 nm and 230/330 nm and those in treated water were 240/410 nm and 220/290 nm. Also, the fluorescent intensity, long excitation wavelength was higher than short excitation wavelength in source water. This phenomena was opposite with treated water.


2013 ◽  
Vol 51 (31-33) ◽  
pp. 6288-6298 ◽  
Author(s):  
Jei-cheol Jeon ◽  
Chang-Hyun Jo ◽  
Ilhwan Choi ◽  
Soon-Buhm Kwon[a] Ennkyung Jang ◽  
Tae-Mun Hwang

Sign in / Sign up

Export Citation Format

Share Document