Taste and odor events in Barcelona's water supply

1995 ◽  
Vol 31 (11) ◽  
pp. 63-68 ◽  
Author(s):  
F. Ventura ◽  
L. Matia ◽  
J. Romero ◽  
MaR. Boleda ◽  
I. Martí ◽  
...  

Two cases of taste and odor episodes in raw and groundwater in the Barcelona (NE Spain) metropolitan area are described. The first was caused by creosote, a distill of coal tar, dumped into river water by two wood-preserving factories. The second taste and odor episode was caused by the presence of a potent odorous compound, the 2-ethyl-5,5-dimethyl-1,3-dioxane, in different groundwater samples. This compound is a by-product present in wastes from resin manufacturing plants that use neopentyl glycol as a raw material for acid-catalysed condensations.

1986 ◽  
Vol 21 (3) ◽  
pp. 351-367 ◽  
Author(s):  
Michael Sklash ◽  
Sharon Mason ◽  
Suzanne Scott ◽  
Chris Pugsley

Abstract We used seepage meters and minipiezometers to survey a 100 m by 7 km band of streambed of the St. Clair River near Sarnia, Ontario, Canada, to determine the quantity, quality, and sources of groundwater seepage into the river. The average observed seepage rate, 1.4 x 10−8 m3/s/m2, suggests higher than expected hydraulic conductivities and/or hydraulic gradients in the streambed. We found detectable levels of some organic contaminants in streambed groundwater samples from 1.0 and 1.5 m depths, however , concentrations did not exceed drinking water guidelines. Our isotopic and electrical conductivity data indicate that: (l) the streambed groundwater is not just river water, (2) groundwater from the “freshwater aquifer” at the base of the overburden Is not a significant component of the streambed groundwater, (3) some of the streambed groundwater is partially derived from a shallow groundwater flow system, and (4) an unidentified source of water with low tritium, river water-like δ18O, and very high electrical conductivity, contributes to the streambed groundwater.


Water ◽  
2021 ◽  
Vol 13 (5) ◽  
pp. 720
Author(s):  
Anna Jurado ◽  
Enric Vázquez-Suñé ◽  
Estanislao Pujades

Pharmaceuticals, such as non-steroidal anti-inflammatory drugs (NSAIDs) and their metabolites, have become a major concern due to their increasing consumption and their widespread occurrence in the environment. In this paper, we investigate the occurrence of NSAIDs and their metabolites in an urban aquifer, which may serve as a potential resource for drinking water, and propose a methodology to assess the removal of these substances in the river–groundwater interface. Then, risk quotients (RQs) are computed, in order to determine the risk posed by the single NSAIDs and their mixture to human health. To this end, six NSAIDs and two metabolites were collected from an urban aquifer located in the metropolitan area of Barcelona (NE, Spain), in which the major pollution source is a contaminated river. All of the target NSAIDs were detected in groundwater samples, where the concentrations in the aquifer were higher than those found in the river water (except for ibuprofen). Diclofenac, ketoprofen, propyphenazone and salicylic acid were detected at high mean concentrations (ranging from 91.8 ng/L to 225.2 ng/L) in the aquifer. In contrast, phenazone and mefenamic acid were found at low mean concentrations (i.e., lower than 25 ng/L) in the aquifer. According to the proposed approach, the mixing of river water recharge into the aquifer seemed to some extent to promote the removal of the NSAIDs under the sub-oxic to denitrifying conditions found in the groundwater. The NSAIDs that presented higher mean removal values were 4OH diclofenac (0.8), ibuprofen (0.78), salicylic acid (0.35) and diclofenac (0.28), which are likely to be naturally attenuated under the aforementioned redox conditions. Concerning human health risk assessment, the NSAIDs detected in groundwater and their mixture do not pose any risk for all age intervals considered, as the associated RQs were all less than 0.05. Nevertheless, this value must be taken with caution, as many pharmaceuticals might occur simultaneously in the groundwater.


2014 ◽  
Vol 884-885 ◽  
pp. 91-95
Author(s):  
Shang Chao Yue ◽  
Le Jun Zhao ◽  
Xiu Duo Wang ◽  
Qi Shan Wang ◽  
Feng Hua He

The objectives of this study were to investigate impact of preoxidation on disinfection by-product (DBP) precursors in drinking water via two different preoxidation methods. The full-scale study was conducted on surface river water in a water supply plant in Tianjin, China. Two treatment trains were performed, with prechlorination and preozonation as preoxidation methods, respectively. The water samples were collected on different stages along the treatment processes and analyzed by following organic parameters: dissolved organic carbon (DOC), UV254 and specific ultraviolet absorbance (SUVA). The results indicated that Train 2 with preozonation was more effective to reduce DBP precursors. Preozonation possessed an excellent ability in the removal of UV254 and SUVA, the removal efficiencies were 25.14% and 18.77%, respectively, comparing to the removal rates of 6.66% and 5.64% during prechlorination, separately.


2016 ◽  
Vol 847 ◽  
pp. 366-373
Author(s):  
Chun Zhi Zhao ◽  
Meng Chi Huang ◽  
Yi Liu ◽  
Li Ping Ma

Plastic pipe is a kind of new pipeline material and its output has been increasing in recent years. It is still mainly used for water supply and drainage of buildings and municipal utility industry as well as for safe drinking in rural areas, about half of all plastic pipelines are used for buildings, and the proportion of these pipelines used in other fields is also increasing. Plastic pipeline system's influence on the environment within its life cycle is the focus of researches in recent years. Based on life cycle assessment (LCA), this paper assesses the common water supply and drainage pipelines (PPR, PE and PVC-U) for buildings for resource and energy consumption, non-renewable resource consumption (ADP) of pollution gas emission, greenhouse effect (GWP), acidification effect (AP) and eutrophication (EP) and inhalable inorganics (RI) generated in the process of life cycle from raw material exploitation to produce production and other environmental influence closely related to the national energy conservation and emission reduction policy. The result shows that the influence indexes of non-renewable resource consumption for functional unit of PPR pipe, PE pipe and PVC-U pipe are 2.22×10-5 Kg antimony eq./ kg, 1.51×10-5 Kg antimony eq./ kg, 6.82×10-6 Kg antimony eq./ kg; those of acidification effect are 1.92×10-2kg SO2 eq./ kg, 1.96×10-2g SO2 eq./ kg, 3.90×10-2kg SO2 eq./ kg; those of eutrophication are 2.39×10-3kg PO43-eq./ kg, 2.36×10-3kg PO43-eq./ kg, 3.40×10-3kg PO43-eq./ kg; those of inhalable inorganics are 6.46×10-3 kg PM2.5 eq./ kg, 6.30×10-3 kg PM2.5 eq./ kg, 1.91×10-2 kg PM2.5 eq./ kg; those of greenhouse effect are 3.72kg CO2 eq./ kg, 3.60kg CO2 eq./ kg, 7.93kg CO2 eq./ kg. This result shows that the environmental influence of PPR, PE and PVC-U pipes mainly depends on the raw materials required for producing pipes, so the key of plastic pipeline greening is to reduce the consumption of virgin resin. This investigation creates a database about plastic pipeline's influence on environment within its full life cycle for the purpose of laying a foundation for calculating intrinsic energy in a building, promoting selection of green building material, facilitating the realization of green building objective, and improving the knowledge of developer, constructor and user to potential influence of the pipeline system within its life cycle.


2020 ◽  
Vol 26 (1) ◽  
pp. 36
Author(s):  
Sepridawati Siregar ◽  
Desi Kiswiranti

AbstrakSungai Klampok mengalir melalui Kecamatan Bergas dan sekelilingnya terdapat beberapa industri sehingga mengakibatkan sungai tersebut tercemar karena menjadi badan penerima air limbah. Akibat penurunan kualitas air Sungai Klampok akan berimbas pada penurunan kualitas air tanah yang digunakan oleh penduduk sekitar sungai tersebut. Penelitian ini bertujuan untuk mengetahui kualitas air tanah yang berada di sekitar Sungai Klampok sebagai akibat adanya pengaruh beban pencemaran oleh air limbah industri berdasarkan Permenkes No. 416/MENKES/PER/IX/1990 tentang persyaratan kualitas air bersih. Lokasi pengambilan sampel air sungai dibagi menjadi 3 stasiun (LK1, LK2 dan LK3) sedangkan untuk sampel airtanah dari rumah-rumah penduduk dilakukan pada 6 titik yaitu 3 titik di daerah utara dari Sungai Klampok (U1,U2, U3) dan 3 titik di daerah selatan dari Sungai Klampok (S1,S2, S3). Pengambilan sampel dilakukan pada musim kemarau. Dari hasil uji kualitas air sungai, pencemaran yang terjadi pada air sungai Klampok masuk dalam kategori tercemar ringan-sedang. Sedangkan hasil uji kualitas air tanah masih berada di bawah baku mutu yang disyaratkan oleh Permenkes No. 416/MENKES/PER/IX/1990, sehingga penurunan kualitas air sungai Klampok tidak mempengaruhi kualitas air tanah di sekitar sungai tersebut. AbstractThe Klampok River flows through the Bergas Subdistrict and there are a number of industries around it, causing the river to become polluted because it becomes the body of the recipient of wastewater. As a result of the decline in the quality of the water in the Klampok River, it will impact on the quality of groundwater used by residents around the river. This study aims to determine the quality of groundwater around the Klampok River as a result of the influence of pollution load by industrial wastewater based on Permenkes No. 416 / MENKES / PER / IX / 1990 concerning requirements for clean water quality. The location of river water sampling is divided into 3 stations (LK1, LK2, and LK3) while for groundwater samples from residential houses is carried out at 6 points, namely 3 points in the northern area of Klampok River (U1, U2, U3) and 3 points in the area south of the Klampok River (S1, S2, S3). Sampling is done in the dry season. From the results of the test of river water quality, pollution that occurs in Klampok river water is categorized as mild-moderate polluted. While the results of groundwater quality testing are still below the quality standards required by Permenkes No. 416 / MENKES / PER / IX / 1990 so that the decline in the water quality of the Klampok river does not affect the quality of groundwater around the river.


2020 ◽  
Vol 17 (35) ◽  
pp. 346-353
Author(s):  
Ketevan KUPATADZE

The article examines the chemical pollution of the Iori River, one of the most important rivers in Georgia. In addition to Georgia, this river is found in Azerbaijan. The study of this river is crucial as LLC United Water Supply Company of Georgia organizes the water supply of big cities and villages of Georgia through Iori water. Furthermore, the population of two big villages independently uses the river water for various household activities: washing (laundry, products, dishware), livestock watering, and irrigation. They do not use it as drinking water. The water of the Iori River was monitored in two sections: village Sasadilo and village Sartichala. In total, 24 samples were taken over the course of 2018 and 2019 years. Some part of the research was conducted on the site through HI83399-02 | Water Wastewater Multiparameter (with COD) Photometer and pH meter device. These studies included pH, BOD, and the temperature was measured directly during sampling. The same device was used for measuring approximate concentrations of heavy metals. At the next stage of the study, an inhabitants survey was conducted to identify their knowledge of environmental cleanliness and safety concerns. As a result of the study, our recommendation to the population is to refrain or restrict the use of untreated river water directly in domesticities. The results of the survey showed that the population has less information about the likelihood of getting heavy metals in the body and developing tumor diseases.


2015 ◽  
Vol 4 ◽  
pp. 625-632
Author(s):  
H.C. Chinnagiri Gowda ◽  
K. Girisha ◽  
Chandan C. Gowda
Keyword(s):  

2006 ◽  
Vol 54 (3) ◽  
pp. 17-21 ◽  
Author(s):  
S.J. Freitas ◽  
G.M. Brion ◽  
L. Black ◽  
T. Coakley

Kentucky river water samples were collected at the input of a potable water supply weekly, for a period of two years. Eighteen parameters were analysed and/or recorded for each weekly observation. The variables were of a physical, chemical and biological nature. Enteric virus presence was detected by cell culture analysis from ∼200 L samples of river water. A database of 108 observations was assembled. Of these only 100 complete observations were used for the modelling analysis. Model input parameters were selected solely based on their statistical significance in forward, backward and stepwise selection procedures. Multivariate logistic regression (MLR) was used to determine the relative significance of the input parameters for predicting the presence or absence of enteric virus. The final, best-fit MLR model that used log-transformed values for enterococci, the AC/TC ratio, faecal coliforms (FC) and temperature demonstrated 82.5 and 81.4% sensitivity and specificity, respectively.


Sign in / Sign up

Export Citation Format

Share Document