Biological odour control by diffusion into activated sludge basins

2000 ◽  
Vol 41 (6) ◽  
pp. 127-132 ◽  
Author(s):  
R. P. Bowker

Diffusion of odourous air into activated sludge basins is an effective and economical approach for odour control at wastewater treatment plants. Over 30 facilities in North America practice this technique. Most of these applications are for dilute or moderate strength air streams with relatively low hydrogen sulfide (H2S) levels. Unfortunately, the lack of data documenting the effectiveness of the process and concerns for blower corrosion have limited its acceptance as a method for controlling odour emissions. This paper presents a compilation and review of wastewater treatment facilities that are currently using activated sludge diffusion. Performance data are tabulated, and information on operation and maintenance of the blower/diffuser systems are summarized. New data are presented that compare the effectiveness of coarse vs. fine bubble diffusers for treatment of a high strength, high-H2S air stream from sludge holding tanks at Concord, NH. Designand performance information is presented on a dedicated odour control system installed at Phoenixville, Pennsylvania in 1996 that collects high-H2S air streams from an influent chamber and primary clarifiers and diffuses it into a mechanically-aerated activated sludge basin. A cost-effectiveness analysis is presented for a blower/diffuser system installed exclusively for odour control. Methods used to overcome initial operational problems are discussed.

2019 ◽  
pp. 243-250
Author(s):  
Regimantas Dauknys

This article presents the wastewater treatment in small settlements and rural areas ofLithuania, including descriptions of capacity and loading of wastewater treatment plants(WWTPs), types of treatment facilities, and development trends of biological treatmentfacilities. In 2000 Lithuania had 597 WWTPs with capacity up to 1000 m3/d, 95% of them arethe biological treatment plants. Today the most of these WWTPs are unloaded due to thetendency to centralise wastewater treatment in rural areas of Lithuania that were in the eightand ninth decades.In small settlements and rural areas of Lithuania the aeration facilities are predominant. In theeight and ninth decades practically only the activated sludge systems were built. The situationbegan to change in the last decade of the last century: the biological filters and soil filtrationfacilities with discharge into surface waters were applied more frequently, so the building ofaeration facilities started to decrease.


1988 ◽  
Vol 20 (4-5) ◽  
pp. 261-266 ◽  
Author(s):  
F. B. Frechen

Odour emissions caused by wastewater treatment plants can bring serious annoyance to the plant's staff and local residents. A measurement technique is required that corresponds to the human impression of smell. Thus, olfactometry was used to determine the odour strength. Many facts contribute to the formation and release of odorous emissions. Surveys as well as measurement programs indicate that the sludge part of a wastewater treatment plant is the most critical part. Different types of waste air treatment plants are in use in West Germany. Regarding the total amount of waste air to be deodorized, chemical scrubbers play the major role today. Looking at the numbers of plants, bio-filters are most common. Biological waste air treatment systems are of increasing importance in West Germany.


2000 ◽  
Vol 41 (6) ◽  
pp. 81-88 ◽  
Author(s):  
A. McIntyre

The use of modelling techniques for predicting the dispersion of odours from wastewater treatment plants is considered in relation to both the resolution of odour problems and the design requirements for new facilities. The issues of community odour annoyance and nuisance are discussed in the context of modelling averaging times, short-term odour peaks and the nature of the individual odours. In addition, the derivation of acceptable odour annoyance criteria is discussed with a comparison of different international approaches and a practical approach to resolving design criteria is proposed. Four case studies include the analysis and resolution of severe odour problems at two major wastewater treatment facilities and the evaluation of “Cordons Sanitaire” in the planning of new housing developments. In the first two cases, modelling was used to identify the most significant processes in terms of off-site effects and then to assess the required abatement level to achieve an acceptable complaints frequency. Inthe third case, dispersion modelling was used to assess the effectiveness of planned odour control measures in the release of land for residential development. The fourth case study demonstrates how an overly-stringent approach to odour control can cause problems.


2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Young Kyung Kim ◽  
Keunje Yoo ◽  
Min Sung Kim ◽  
Il Han ◽  
Minjoo Lee ◽  
...  

Abstract Bacterial communities in wastewater treatment plants (WWTPs) affect plant functionality through their role in the removal of pollutants from wastewater. Bacterial communities vary extensively based on plant operating conditions and influent characteristics. The capacity of WWTPs can also affect the bacterial community via variations in the organic or nutrient composition of the influent. Despite the importance considering capacity, the characteristics that control bacterial community assembly are largely unknown. In this study, we discovered that bacterial communities in WWTPs in Korea and Vietnam, which differ remarkably in capacity, exhibit unique structures and interactions that are governed mainly by the capacity of WWTPs. Bacterial communities were analysed using 16S rRNA gene sequencing and exhibited clear differences between the two regions, with these differences being most pronounced in activated sludge. We found that capacity contributed the most to bacterial interactions and community structure, whereas other factors had less impact. Co-occurrence network analysis showed that microorganisms from high-capacity WWTPs are more interrelated than those from low-capacity WWTPs, which corresponds to the tighter clustering of bacterial communities in Korea. These results will contribute to the understanding of bacterial community assembly in activated sludge processing.


Author(s):  
Hisashi Satoh ◽  
Yukari Kashimoto ◽  
Naoki Takahashi ◽  
Takashi Tsujimura

A deep learning-based two-label classifier 1 recognized a 20% morphological change in the activated flocs. Classifier-2 quantitatively recognized an abundance of filamentous bacteria in activated flocs.


1999 ◽  
Vol 40 (11-12) ◽  
pp. 223-229 ◽  
Author(s):  
Frédéric Clauss ◽  
Christel Balavoine ◽  
Delphine Hélaine ◽  
Gaëtan Martin

Forest industry wastewaters are difficult to clean: hydraulic and organic load variations, filamentous bulking or pin-point flocs negatively impact depollution processes. The addition of a fine, mineral, talc-based powder, Aquatal, into the aeration tanks of wastewater treatment plants connected to pulp and paper factories has been successfully tested since end of '97. The first case-study presents full results obtained over a period of 18 months in a 20,000 p.e. plant connected to a paper factory. The mineral powder was regularly added to control sludge volume index, thereby ensuring low suspended solids concentration in the outfluent. Plant operators could easily adapt biomass concentration to match organic load variation, thereby maintaining pollution micro-organisms ratio constant. In a second case study, a trouble-shooting strategy was implemented to counteract filamentous bulking. A one-off, large dosage enabled the plant operator to deal effectively with poor settleability sludge and rapidly control sludge blanket expansion. In both cases, the main common characteristics observed were an increase in floc aggregation and the production of heavier and well-structured flocs. The sludge settling velocity increased and an efficient solid/liquid separation was obtained. After a few days, the mineral particles of Aquatal were progressively integrated into the sludge floc structure. When the mineral powder was added to the activated sludge in the aeration basin, chemical interactions frequently encountered with other wastewater treatment additives did not pose a problem. Moreover, with this mineral additive, the biological excess sludge displayed good thickening properties and dewatering was improved. Despite the addition of the insoluble mineral particles, the amount of wet sludge expelled did not increase. Aquatal offers a rapid solution to floc settleability problems which so frequently arise when physical or biological disorders appear in forest industry wastewater treatment plants.


1994 ◽  
Vol 30 (4) ◽  
pp. 211-214 ◽  
Author(s):  
E. Brands ◽  
M. Liebeskind ◽  
M. Dohmann

This study shows a comparison of important parameters for dynamic simulation concerning the highrate and low-rate activated sludge tanks of several municipal wastewater treatment plants. The parameters for the dynamic simulation of the single-stage process are quite well known, but parameters for the high-ratellow-rate activated sludge process are still missi ng, although a considerable number of wastewater treatment plants are designed and operated that way. At present any attempt to simulate their operation is restricted to the second stage due to missing data concerning growth rate, decay rate, yield coefficient and others.


1992 ◽  
Vol 25 (6) ◽  
pp. 125-139 ◽  
Author(s):  
J. Kappeler ◽  
W. Gujer

To predict the behaviour of biological wastewater treatment plants, the Activated Sludge Model No. 1 is often used. For the application of this model kinetic parameters and wastewater composition must be known. A simple method to estimate kinetic parameters of heterotrophic biomass and COD wastewater fractions is presented. With three different types of batch-tests these parameters and fractions can be determined by measuring oxygen respiration. Our measurements showed that the maximum specific growth rate µmax of heterotrophic biomass depends on temperature, reactor configuration and SRT. In typical wastewater treatment plants of Switzerland the amount of readily biodegradable substrate was generally small (about 9 % of the COD in primary effluent). The same method can also be used to determine kinetic parameters of nitrifying biomass.


Sign in / Sign up

Export Citation Format

Share Document