Application of a membrane bioreactor system for opto-electronic industrial wastewater treatment - a pilot study

2003 ◽  
Vol 48 (8) ◽  
pp. 195-202 ◽  
Author(s):  
T.K. Chen ◽  
J.N. Chen ◽  
C.H. Ni ◽  
G.T. Lin ◽  
C.Y. Chang

The membrane bioreactor (MBR) system has become more and more attractive in the field of wastewater treatment. It is particularly attractive in situations where long solids retention times are required, such as nitrifying bacteria, and physical retention is critical to achieving more efficiency for biological degradation of pollutants. Although it is a new technology, the MBR process has been applied to industrial wastewater treatment for only the past decade. The opto-electronic industry, developed very fast over the past decade in the world, is a high technological manufacturing industry. The treatment of the opto-electronic industrial wastewater containing a significant quantity of organic nitrogen compounds, with a ratio over 95% in organic nitrogen (Org-N) to total nitrogen (T-N), is very difficult to meet the discharge limits. The purpose of this research is mainly to discuss the treatment capacity of high-strength organic nitrogen wastewater, and to investigate the capabilities of the MBR process. A 2 m3/day capacity MBR pilot plant consisting of anoxic and aerobic tanks and a membrane bioreactor was installed for evaluation. The operation was continued for 130 days. Over the whole experimental period, a satisfactory organic removal performance was achieved. The COD could be removed with an average of over 94.5%. For TOC and BOD5, the average removal efficiencies were 96.3 and 97.6%, respectively. The nitrification and denitrification were also successfully achieved. The effluent did not contain any suspended solids. Only a small concentration of ammonia nitrogen was found in the effluent. The stable effluent quality and satisfactory removal performance mentioned above were ensured by the efficient interception performance of the membrane device incorporated within the biological reactor. The MBR system shows promise as a means of treating very high organic nitrogen wastewater without dilution. The effluent of TKN, NOx-N and COD can fall below 20 mg/L, 30 mg/L and 50 mg/L.

2003 ◽  
Vol 48 (1) ◽  
pp. 191-198 ◽  
Author(s):  
T.K. Chen ◽  
C.H. Ni ◽  
J.N. Chen ◽  
J. Lin

The membrane bioreactor (MBR) system has become more and more attractive in the field of wastewater treatment. It is particularly attractive in situations where long solids retention times are required, such as nitrifying bacteria, and physical retention critical to achieving more efficiency for biological degradation of pollutant. Although it is a new technology, the MBR process has been applied for industrial wastewater treatment for only the past decade. The opto-electronic industry, developed very fast over the past decade in the world, is high technology manufacturing. The treatment of the opto-electronic industrial wastewater containing a significant quantity of organic nitrogen compounds with a ratio over 95% in organic nitrogen (Org-N) to total nitrogen (T-N) is very difficult to meet the discharge limits. This research is mainly to discuss the treatment capacity of high-strength organic nitrogen wastewater, and to investigate the capabilities of the MBR process. A 5 m3/day capacity of MBR pilot plant consisted of anoxic, aerobic and membrane bioreactor was installed for evaluation. The operation was continued for 150 days. Over the whole experimental period, a satisfactory organic removal performance was achieved. The COD could be removed with an average of over 94.5%. For TOC and BOD5 items, the average removal efficiencies were 96.3 and 97.6%, respectively. The nitrification and denitrification was also successfully achieved. Furthermore, the effluent did not contain any suspended solids. Only a small concentration of ammonia nitrogen was found in the effluent. The stable effluent quality and satisfactory removal performance mentioned above were ensured by the efficient interception performance of the membrane device incorporated within the biological reactor. The MBR system shows promise as a means of treating very high organic nitrogen wastewater without dilution. The effluent of TKN, NOx-N and COD can fall below 20 mg/L, 30 mg/L and 50 mg/L.


2018 ◽  
Vol 2018 ◽  
pp. 1-14 ◽  
Author(s):  
Lennevey Kinidi ◽  
Ivy Ai Wei Tan ◽  
Noraziah Binti Abdul Wahab ◽  
Khairul Fikri Bin Tamrin ◽  
Cirilo Nolasco Hipolito ◽  
...  

It is noteworthy to highlight that ammonia nitrogen contamination in wastewater has been reported to pose a great threat to the environment. This conventional method of remediating ammonia nitrogen contamination in wastewater applies the packed bed tower technology. Nevertheless, this technology appears to pose several application issues. Over the years, researchers have tested various types of ammonia stripping process to overcome the shortcomings of the conventional ammonia stripping technology. Along this line, the present study highlights the recent development of ammonia stripping process for industrial wastewater treatment. In addition, this study reviews ammonia stripping application for varied types of industrial wastewater and several significant operating parameters. Furthermore, this paper discusses some issues related to the conventional ammonia stripper for industrial treatment application. Finally, this study explicates the future prospects of the ammonia stripping method. This review, hence, contributes by enhancing the ammonia stripping treatment efficiency and its application for industrial wastewater treatment.


2004 ◽  
Vol 23 (1) ◽  
pp. 59-68 ◽  
Author(s):  
B. Marrot ◽  
A. Barrios-Martinez ◽  
P. Moulin ◽  
N. Roche

2003 ◽  
Vol 48 (8) ◽  
pp. 27-34 ◽  
Author(s):  
T.-K. Chen ◽  
C.-H. Ni ◽  
J.-N. Chen

Development and application of biological nutrient removal processes accelerated significantly over the past decade due to more stringent nutrients (nitrogen and phosphorus) discharge limits being imposed on wastewater treatment plants. The opto-electronic industry has developed very fast over the past decade in the world. The wastewater often contains a significant quantity of organic nitrogen compounds and has a ratio of over 95% in organic nitrogen (Org-N) to total nitrogen (T-N). In this study, a 2-stage Anoxic/Aerobic pre-denitrification process was established and the efficiency of wastewater treatment was evaluated. Wastewater from an actual LCD-plant was obtained as the sample for looking into the feasibility of opto-electronic industrial wastewater treatment. Hydraulic retention time (HRT) and mixed liquor recycle rate (MLR) were controlled independently to distinguish between the effects of these two factors. Under suitable HRT and mixed liquor recycle ratio, effluents of NH4-N, NOx-N and COD can fall below 20 mg/l, 30 mg/l and 80 mg/l.


2012 ◽  
Vol 610-613 ◽  
pp. 1426-1431 ◽  
Author(s):  
Yuan Hong Ding ◽  
Qing Wang ◽  
Hong Qiang Ren

a submerged membrane bioreactor was used to treat the effluent of a pharmaceutical wastewater treatment system, the treated water is rich in ammonia nitrogen and organic compounds (NH4-N, averaged in 78.1 mg/L; COD, averaged in 189.5 mg/L), the final effluent of membrane bioreactor was stably below 50 mg/L COD and 40 mg/L NH4-N respectively, the activity of nitrifying bacteria was inhibited by high concentrations of organic compounds and ammonia nitrogen, a rapid declination of filtration was probably resulted form high concentrations of organic compounds and biomass.


2016 ◽  
Vol 510 ◽  
pp. 524-532 ◽  
Author(s):  
Shamim Ahmed Deowan ◽  
Francesco Galiano ◽  
Jan Hoinkis ◽  
Daniel Johnson ◽  
Sacide Alsoy Altinkaya ◽  
...  

2017 ◽  
Vol 245 ◽  
pp. 207-215 ◽  
Author(s):  
Amine Charfi ◽  
Narumol Thongmak ◽  
Boumediene Benyahia ◽  
Muhammad Aslam ◽  
Jérôme Harmand ◽  
...  

ChemInform ◽  
2011 ◽  
Vol 42 (33) ◽  
pp. no-no ◽  
Author(s):  
Faisal Ibney Hai ◽  
Kazuo Yamamoto ◽  
Fumiyuki Nakajima ◽  
Kensuke Fukushi

Sign in / Sign up

Export Citation Format

Share Document