ADM1-based methodology for the characterisation of the influent sludge in anaerobic reactors

2006 ◽  
Vol 54 (4) ◽  
pp. 157-166 ◽  
Author(s):  
E. Huete ◽  
M. de Gracia ◽  
E. Ayesa ◽  
J.L. Garcia-Heras

This paper presents a systematic methodology to characterise the influent sludge in terms of the ADM1 components from the experimental measurements traditionally used in wastewater engineering. For this purpose, a complete characterisation of the model components in their elemental mass fractions and charge has been used, making a rigorous mass balance for all the process transformations and enabling the future connection with other unit-process models. It also makes possible the application of mathematical algorithms for the optimal characterisation of several components poorly defined in the ADM1 report. Additionally, decay and disintegration have been necessarily uncoupled so that the decay proceeds directly to hydrolysis instead of producing intermediate composites. The proposed methodology has been applied to the particular experimental work of a pilot-scale CSTR treating real sewage sludge, a mixture of primary and secondary sludge. The results obtained have shown a good characterisation of the influent reflected in good model predictions. However, its limitations for an appropriate prediction of alkalinity and carbon percentages in biogas suggest the convenience of including the elemental characterisation of the process in terms of carbon in the analytical program.

2007 ◽  
Vol 56 (8) ◽  
pp. 95-106 ◽  
Author(s):  
P. Grau ◽  
S. Beltrán ◽  
M. de Gracia ◽  
E. Ayesa

This paper proposes a new methodology for the automatic characterization of the influent wastewater in WWTP. With this methodology, model components are automatically estimated by means of optimization algorithms combining a-priori knowledge of the expected wastewater composition with experimental information from the available measurement data. The characterization is carried out based on an extended model components list in which components are described by means their elemental mass fractions. This allows an easy establishment of relationships between model components with experimental data and also, to obtain a general methodology applicable to any model used for wastewater biological treatments. The characterization of the wastewater influent of Galindo-Bilbao according this methodology has demonstrated its validity and the easy application to the ASM1 model influent characterization.


2006 ◽  
Vol 53 (1) ◽  
pp. 225-240 ◽  
Author(s):  
M. de Gracia ◽  
L. Sancho ◽  
J.L. García-Heras ◽  
P. Vanrolleghem ◽  
E. Ayesa

This paper proposes a systematic methodology for the analysis of the mass and charge balances in dynamic models expressed using the Petersen matrix notation. This methodology is based on the definition of the model components via elemental mass fractions and in the estimation of the COD as a function of the redox equations associated with these elements. This approach makes the automatic calculation of all the stoichiometric coefficients under different measuring units and the study of COD, charge or mass fluxes easier. As an example of its application this methodology was applied to the ADM1 in order to illustrate its usefulness for the analysis of organic matter characterisation, nitrogen release or biogas composition in anaerobic digestion. The application of the methodology for a rigorous integration of different IWA models is proposed for further study.


2002 ◽  
Vol 124 (4) ◽  
pp. 791-799 ◽  
Author(s):  
Achintya Mukhopadhyay ◽  
Xiao Qin ◽  
Suresh K. Aggarwal ◽  
Ishwar K. Puri

A new formulation for extending the concept of heatlines and masslines to reacting flows through use of conserved scalars has been proposed. The formulation takes into account the distinct diffusion coefficients of different species. Results have been obtained for a number of two-dimensional nonreacting and reacting free shear flows under normal and zero gravity. For nonreacting flows, total enthalpy and elemental mass fractions have been used as the transported conserved scalars. For reacting flows, mixture fractions, defined as normalized elemental mass fractions and enthalpy, have been employed. The results show this concept to be a useful tool for obtaining better insights into the global qualitative picture of scalar transport for both nonreacting and reacting flows.


2015 ◽  
Vol 72 (8) ◽  
pp. 1446-1454 ◽  
Author(s):  
Qirong Dong ◽  
Martha Dagnew ◽  
Jeff Cumin ◽  
Wayne Parker

This study assessed the characteristics of biosolids of a pilot-scale anaerobic membrane bioreactor (AnMBR) treating municipal wastewater. The production of total solids (TS) and volatile solids (VS) was comparable to that reported for the extended aeration system at solids residence time (SRT) longer than 40 days. The yields of TS and VS were reduced as SRT increased from 40 to 100 days and increased with the addition of 26 mg/L of FeCl3. The AnMBR destroyed 60–82% of the VS loading in feed wastewater and hence it was concluded the biosolids met the requirements for vector attraction reduction for land application. The concentrations of volatile suspended solids and total suspended solids in the sludge were less than those reported after anaerobic digestion of conventional primary and secondary sludge mixtures, and hence dewatering of the waste stream may be required for some applications. The nutrient content in terms of total Kjeldahl nitrogen and total phosphorus was similar to that of anaerobically digested municipal sludges. The dewaterability of the biosolids was poorer than that reported for sludges from aerobic treatment and anaerobically digested sludges. Dewaterability was improved by addition of FeCl3 and reduced SRT. The biosolids met standards for land application with regards to the concentration of heavy metals but would need further treatment to meet Class B pathogen indicator criteria.


2003 ◽  
Vol 47 (11) ◽  
pp. 9-15 ◽  
Author(s):  
T. McCue ◽  
R. Shah ◽  
I. Vassiliev ◽  
Y.-H. Liu ◽  
F.G. Eremektar ◽  
...  

The objective of this NSF sponsored research was to provide a controlled comparison of identical continuous flow biological nutrient removal (BNR) processes both with and without prefermentation in order to provide a stronger, more quantitative, technical basis for design engineers to determine the potential benefits of prefermentation to EBPR in treating domestic wastewater. Specifically, this paper focused upon the potential impacts of primary influent prefermentation upon BNR processes treating septic domestic wastewater. This study can be divided into two distinct phases - an initial bench-scale phase which treated septic P-limited (TCOD:TP>40) wastewater and a subsequent pilot-scale phase which treated septic COD-limited (TCOD:TP<40) wastewater. The following conclusions can be drawn from the results obtained to date.•Prefermentation increased both RBCOD, SBCOD and VFA content of septic domestic wastewater.•Prefermentation resulted in increased biological P removal for a highly septic, non-P limited (TCOD:TP<40:1) wastewater. However, in septic, P-limited (TCOD:TP>40:1) wastewater, changes in net P removal due to prefermentation were suppressed by limited P availability, even though P release and PHA content were affected.•Prefermentation increased specific anoxic denitrification rates for both COD and P-limited wastewaters, and in the pilot (COD-limited) study also coincided with greater system N removal.


2009 ◽  
Vol 60 (6) ◽  
pp. 1525-1532 ◽  
Author(s):  
S. Pérez-Elvira ◽  
M. Fdz-Polanco ◽  
F. I. Plaza ◽  
G. Garralón ◽  
F. Fdz-Polanco

Prior research indicates that ultrasounds can be used in batch reactors as pre-treatment before anaerobic digestion, but the specific energy required at laboratory-scale is too high. This work evaluates both the continuous ultrasound device performance (efficiency and solubilisation) and the operation of anaerobic digesters continuously fed with sonicated sludge, and presents energy balance considerations. The results of sludge solubilisation after the sonication treatment indicate that, applying identical specific energy, it is better to increase the power than the residence time. Working with secondary sludge, batch biodegradability tests show that by applying 30 kWh/m3 of sludge, it is possible to increase biogas production by 42%. Data from continuous pilot-scale anaerobic reactors (V=100 L) indicate that operating with a conventional HRT = 20 d, a reactor fed with pre-treated sludge increases the volatile solids removal and the biogas production by 25 and 37% respectively. Operating with HRT = 15 d, the removal efficiency is similar to the obtained with a reactor fed with non-hydrolysed sludge at HTR = 20 d, although the specific biogas productivity per volume of reactor is higher for the pretreated sludge. Regarding the energy balance, although for laboratory-scale devices it is negative, full-scale suppliers state a net generation of 3–10 kW per kW of energy used.


2019 ◽  
Author(s):  
Dongmei Feng ◽  
Edward Beighley

Abstract. Assessing the impacts of climate change on hydrologic systems is critical for developing adaptation and mitigation strategies for water resource management, risk control and ecosystem conservation practices. Such assessments are commonly accomplished using outputs from a hydrologic model forced with future precipitation and temperature projections. The algorithms used in the hydrologic model components (e.g., runoff generation) can introduce significant uncertainties in the simulated hydrologic variables, yet the identification and quantification of such uncertainties is rarely studied. Here, a modeling framework is developed that integrates multiple runoff generation algorithms with a routing model and associated parameter optimizations. This framework is able to identify uncertainties from both hydrologic model components and climate forcings as well as associated parameterization. Three fundamentally different runoff generation approaches: runoff coefficient method (RCM, conceptual), variable infiltration capacity (VIC, physically-based, infiltration excess) and simple-TOPMODEL (STP, physically-based, saturation excess), are coupled with Hillslope River Routing model to simulate streamflow. A case study conducted in Santa Barbara County, California, reveals that the median changes are 1–10 % increases in mean annual discharge (Qm) and 10–40 % increases in annual maximum daily discharge (Qp) and 100-yr flood discharge (Q100). The Bayesian Model Averaging analysis indicates that the probability of increase in streamflow can be up to 85 %. However, the simulated discharge uncertainties are large (i.e., 230 % for Qm and 330 % for Qp and Q100) with general circulation models (GCMs) and emission scenarios accounting for more than half of the total uncertainty. Hydrologic process models contribute 10–30 % of the total uncertainty, while uncertainty due to hydrologic model parameterization is almost negligible (


1985 ◽  
Vol 17 (11-12) ◽  
pp. 287-288 ◽  
Author(s):  
R. Ramadori ◽  
V. Tandoi ◽  
A. Misiti

In connection with studies aimed at developing low-energy wastewater treatment processes considerable interest has been shown in the possibility of removal of phosphorus biologically rather than chemically. The results over one year from bench and pilot scale tests conducted with synthetic and settled domestic wastewaters respectively are reported. The pilot plant was installed in one of the Rome urban wastewater treatment works and consisted of a two stage (anaerobic-aerobic) system. The wastewater was withdrawn downstream from the primary settling tank and conveyed to the anaerobic reactor of the pilot plant. A similar experiment was conducted in a three reactor (two anaerobic and one aerobic) bench scale plant, where a synthetic solution (peptone, sodium acetate and potassium phosphate) was fed under rigorously controlled conditions of temperature, pH and dissolved oxygen. Both bench and pilot scale tests were designed to verify and quantify the biological removal of phosphorus; the performances of both phosphorus removal test scale systems were compared with those from a reference aerobic plant operating under the same conditions. The impact of several parameters on the biological removal of phosphorus were examined. These parameters were: nature of carbonaceous substrate, carbonaceous/phosphorus ratio, sludge age; etc. Considerable care and attention was given to checking phosphorus balances, once the steady state conditions had been obtained. The results can be summarized as follows:-Phosphorus removal was found to be greater in plants with an anaerobic stage than in the reference plants. At pilot scale level this is clearly shown by the plot of the daily phosphate concentration in the effluents. At bench scale it is shown by comparison between P contents in sludges (9.9% vs. 5.0%) and by the fact that, at the end of the experiment, large deposits of inorganic phosphate (mainly of Ca and Mg) were found on the walls of both anaerobic reactors. The unstable operating conditions of the reference plant due to the poor sedimentation characteristics of the sludges leading to uncontrolled losses of biomass meant it was impossible to obtain a reliable mean phosphorus abatement value, which in any case was always well below that found for the P-removal plant.-As reported above, the deficit in the phosphorus balance was due to inorganic phosphate precipitation. In this connection an excellent quantitative agreement was found between the deficit in the balance and the quantity of phosphorus collecting in the anaerobic reactors.-Phosphorus release from the biomass under anaerobic conditions has already been completed in the first anaerobic reactor (where carbonaceous substrate uptake also occurs) and the use of the second anaerobic reactor seems to allow a more complete phosphate precipitation.-Part of the carbonaceous substrate which disappears during the first anaerobic stage is metabolized. In fact, in this reactor, the complete disappearance of organic nitrogen is accompanied by the release of large quantities of ammoniacal nitrogen. Lastly, despite the fact that the values of the main operative parameters, such as hydraulic retention time, sludge age, temperature, pH and dissolved oxygen, were kept rigorously constant, a certain instability was found in the biomass as regards the maintaining of such high phosphorus removal efficiencies over long periods of time. This may be due to the highly variable biological population dynamics.


2009 ◽  
Vol 59 (9) ◽  
pp. 1847-1853 ◽  
Author(s):  
R. C. Leitão ◽  
S. T. Santaellla ◽  
A. C. van Haandel ◽  
G. Zeeman ◽  
G. Lettinga

The effects of hydraulic retention time (HRT) and influent COD concentration (CODInf) on Specific Methanogenic Activity (SMA) and the biodegradability of an anaerobic sludge need to be elucidated because of the discordant results available in literature. This information is important for the operation of anaerobic reactors and design of the sludge post-treatment unit. For this study, sludge samples obtained from eight pilot-scale Upflow Anaerobic Sludge Blanket (UASB) reactors were tested. The reactors were fed with municipal wastewater and operated with different sets of HRT and influent concentrations until the steady state was established. The results show that at a lower HRT, sludge with relatively higher SMA develops. A slight trend of declining SMA at increasing CODInf was found for reactors operated at longer HRTs; however, further experiments are necessary for more definitive conclusions. The sludge from reactors operated at longer HRTs and with lower CODInf resulted in lower biodegradability. Results also showed that it is ineffective to design a UASB reactor with a longer HRT to cope with organic shock loads.