scholarly journals Systematic errors in extracting nucleon properties from lattice QCD

Author(s):  
Bastian Knippschild ◽  
Hartmut Wittig ◽  
Stefano Capitani ◽  
Michele Della Morte
2006 ◽  
Vol 21 (04) ◽  
pp. 865-868
Author(s):  
◽  
STEFAN SINT

I report on a recent determination by the ALPHA collaboration of the kaon B-parameter using lattice QCD with Wilson type quarks. An effort is made to control all systematic errors except for the quenched approximation. The preliminary result for the renormalization group invariant parameter is [Formula: see text], which translates to [Formula: see text] in the [Formula: see text] scheme with anticommuting γ5.


2004 ◽  
Vol 19 (06) ◽  
pp. 877-886 ◽  
Author(s):  
P. LEPAGE ◽  
C. DAVIES

We review recent results in lattice QCD from numerical simulations that allow for a much more realistic QCD vacuum than has been possible before. Comparison with experiment for a variety of hadronic quantities gives agreement to within statistical and systematic errors of 3%. We discuss the implications of this for future calculations in lattice QCD, particularly those which will provide input for B-factory experiments.


2021 ◽  
Vol 81 (7) ◽  
Author(s):  
En-Hung Chao ◽  
Renwick J. Hudspith ◽  
Antoine Gérardin ◽  
Jeremy R. Green ◽  
Harvey B. Meyer ◽  
...  

AbstractWe compute the hadronic light-by-light scattering contribution to the muon $$g-2$$ g - 2 from the up, down, and strange-quark sector directly using lattice QCD. Our calculation features evaluations of all possible Wick-contractions of the relevant hadronic four-point function and incorporates several different pion masses, volumes, and lattice-spacings. We obtain a value of $$a_\mu ^{\text {Hlbl}}= 106.8(15.9) \times 10^{-11}$$ a μ Hlbl = 106.8 ( 15.9 ) × 10 - 11 (adding statistical and systematic errors in quadrature), which is consistent with current phenomenological estimates and a previous lattice determination. It now appears conclusive that the hadronic light-by-light contribution cannot explain the current tension between theory and experiment for the muon $$g-2$$ g - 2 .


2021 ◽  
Vol 2021 (11) ◽  
Author(s):  
Joseph Karpie ◽  
Kostas Orginos ◽  
Anatoly Radyushkin ◽  
Savvas Zafeiropoulos ◽  

Abstract In this study, we present continuum limit results for the unpolarized parton distribution function of the nucleon computed in lattice QCD. This study is the first continuum limit using the pseudo-PDF approach with Short Distance Factorization for factorizing lattice QCD calculable matrix elements. Our findings are also compared with the pertinent phenomenological determinations. Inter alia, we are employing the summation Generalized Eigenvalue Problem (sGEVP) technique in order to optimize our control over the excited state contamination which can be one of the most serious systematic errors in this type of calculations. A crucial novel ingredient of our analysis is the parameterization of systematic errors using Jacobi polynomials to characterize and remove both lattice spacing and higher twist contaminations, as well as the leading twist distribution. This method can be expanded in further studies to remove all other systematic errors.


1997 ◽  
Vol 12 (22) ◽  
pp. 4029-4038
Author(s):  
James N. Simone

Quarkonia is studied in lattice QCD using Wilson heavy quarks improved to O(a) in the lattice spacing a. The quarkonia spectrum is compared to experiment and provides a check on lattice spacing errors. Careful attention to systematic errors in quarkonia permits determinations of the QCD coupling αs and the heavy quark masses.


1978 ◽  
Vol 48 ◽  
pp. 7-29
Author(s):  
T. E. Lutz

This review paper deals with the use of statistical methods to evaluate systematic and random errors associated with trigonometric parallaxes. First, systematic errors which arise when using trigonometric parallaxes to calibrate luminosity systems are discussed. Next, determination of the external errors of parallax measurement are reviewed. Observatory corrections are discussed. Schilt’s point, that as the causes of these systematic differences between observatories are not known the computed corrections can not be applied appropriately, is emphasized. However, modern parallax work is sufficiently accurate that it is necessary to determine observatory corrections if full use is to be made of the potential precision of the data. To this end, it is suggested that a prior experimental design is required. Past experience has shown that accidental overlap of observing programs will not suffice to determine observatory corrections which are meaningful.


1988 ◽  
Vol 102 ◽  
pp. 215
Author(s):  
R.M. More ◽  
G.B. Zimmerman ◽  
Z. Zinamon

Autoionization and dielectronic attachment are usually omitted from rate equations for the non–LTE average–atom model, causing systematic errors in predicted ionization states and electronic populations for atoms in hot dense plasmas produced by laser irradiation of solid targets. We formulate a method by which dielectronic recombination can be included in average–atom calculations without conflict with the principle of detailed balance. The essential new feature in this extended average atom model is a treatment of strong correlations of electron populations induced by the dielectronic attachment process.


Author(s):  
W.J. de Ruijter ◽  
Sharma Renu

Established methods for measurement of lattice spacings and angles of crystalline materials include x-ray diffraction, microdiffraction and HREM imaging. Structural information from HREM images is normally obtained off-line with the traveling table microscope or by the optical diffractogram technique. We present a new method for precise measurement of lattice vectors from HREM images using an on-line computer connected to the electron microscope. It has already been established that an image of crystalline material can be represented by a finite number of sinusoids. The amplitude and the phase of these sinusoids are affected by the microscope transfer characteristics, which are strongly influenced by the settings of defocus, astigmatism and beam alignment. However, the frequency of each sinusoid is solely a function of overall magnification and periodicities present in the specimen. After proper calibration of the overall magnification, lattice vectors can be measured unambiguously from HREM images.Measurement of lattice vectors is a statistical parameter estimation problem which is similar to amplitude, phase and frequency estimation of sinusoids in 1-dimensional signals as encountered, for example, in radar, sonar and telecommunications. It is important to properly model the observations, the systematic errors and the non-systematic errors. The observations are modelled as a sum of (2-dimensional) sinusoids. In the present study the components of the frequency vector of the sinusoids are the only parameters of interest. Non-systematic errors in recorded electron images are described as white Gaussian noise. The most important systematic error is geometric distortion. Lattice vectors are measured using a two step procedure. First a coarse search is obtained using a Fast Fourier Transform on an image section of interest. Prior to Fourier transformation the image section is multiplied with a window, which gradually falls off to zero at the edges. The user indicates interactively the periodicities of interest by selecting spots in the digital diffractogram. A fine search for each selected frequency is implemented using a bilinear interpolation, which is dependent on the window function. It is possible to refine the estimation even further using a non-linear least squares estimation. The first two steps provide the proper starting values for the numerical minimization (e.g. Gauss-Newton). This third step increases the precision with 30% to the highest theoretically attainable (Cramer and Rao Lower Bound). In the present studies we use a Gatan 622 TV camera attached to the JEM 4000EX electron microscope. Image analysis is implemented on a Micro VAX II computer equipped with a powerful array processor and real time image processing hardware. The typical precision, as defined by the standard deviation of the distribution of measurement errors, is found to be <0.003Å measured on single crystal silicon and <0.02Å measured on small (10-30Å) specimen areas. These values are ×10 times larger than predicted by theory. Furthermore, the measured precision is observed to be independent on signal-to-noise ratio (determined by the number of averaged TV frames). Obviously, the precision is restricted by geometric distortion mainly caused by the TV camera. For this reason, we are replacing the Gatan 622 TV camera with a modern high-grade CCD-based camera system. Such a system not only has negligible geometric distortion, but also high dynamic range (>10,000) and high resolution (1024x1024 pixels). The geometric distortion of the projector lenses can be measured, and corrected through re-sampling of the digitized image.


Sign in / Sign up

Export Citation Format

Share Document