scholarly journals KM3NeT Detection Unit Line Fit reconstruction using positioning sensors data

2021 ◽  
Author(s):  
Chiara Poirè ◽  
Dídac Diego-Tortosa
Keyword(s):  
2021 ◽  
Vol 16 (09) ◽  
pp. C09023
Author(s):  
Dídac D. Tortosa ◽  
C. Poirè
Keyword(s):  

2013 ◽  
Vol 706-708 ◽  
pp. 932-936
Author(s):  
Yan Lv ◽  
Hui Hui Wang ◽  
Xue Heng Tao

The uniformity of thickness of insulation layer on communication cable is an important technique index to guarantee the communication cable has good mechanical and physical properties. Therefore the control method for uniformity of insulation layer on communication cable is desiderated to be researched. In this paper, a control system which took two laser displacement sensors as a detection unit, a CS1G-H PLC of OMRON as a central control unit, two servo drivers and two servo motors of the SMARTSTEP-A series of OMRON as a servo system, a touch screen as a man-machine interface and applied PID and PDFF control algorithms was designed. The system was proved that the operation was reliable and the desired requirements could be achieved based on laboratory simulation and debugging.


2021 ◽  
pp. 1-35
Author(s):  
Giulia Babazzi ◽  
Tommaso Bacci ◽  
Alessio Picchi ◽  
Tommaso Fodelli ◽  
Tommaso Lenzi ◽  
...  

Abstract Modern gas turbines present important temperature distortions in the core-engine flowpath, mainly in the form of hot and cold streaks. As they highly influence turbines performance and lifetime, the precise knowledge of the thermal field evolution through the combustor and the high-pressure turbine is fundamental. The majority of past studies investigated streaks migrations directly examining the thermal field, while a limited amount of experimental work employed approaches based on the detection of tracer gases. The latter approach provides a more detailed evaluation of the evolution and mixing of the different flows. However, the slow time response due to the employment of sampling probes and gas analysers make the investigation extremely time consuming. In this study a commercial oxygen sensor element and its excitation/detection unit were integrated into a newly developed probe to carry out local tracer gas concentration measurements exploiting the fluorescence behaviour. The paper summarizes the probe development and calibration activities, with the characterization of its accuracy for different flow conditions. Finally, two probe applications are described: firstly the probe was used to detect tracer gas concentrations on a jet flow; afterwards it was traversed on the interface plane between a non-reactive, lean combustor simulator and the NGV cascade. The probe has proven to provide accurate and reliable measurements both from a quantitative and qualitative point of view even in highly 3D flow fields typical of gas turbines conditions.


BMJ ◽  
2010 ◽  
Vol 341 (aug20 1) ◽  
pp. c4597-c4597
Author(s):  
A. Jack
Keyword(s):  

2020 ◽  
Vol 46 (Supplement_1) ◽  
pp. S82-S82
Author(s):  
Line Lindhardt ◽  
Morten Lindhardt ◽  
Ulrik Haahr ◽  
Lene Halling Hastrup ◽  
Erik Simonsen ◽  
...  

Abstract Background Psychosis and signs of severe mental disorders such as schizophrenia often emerge in adolescence. Much attention has been devoted to identifying the individuals experiencing psychosis at an early stage. Implementation of early detection services is widely acknowledged as effective in reducing treatment delays. However, little is known about the diagnostic patterns of individuals entering an early detection service regardless of the initial psychopathological evaluation. The aim of the study is to investigate the diagnostic trajectories of individuals evaluated by an early detection of psychosis unit. Methods A real-life cross-sectional study coupling register data with information of diagnoses allocated by clinical evaluation in an early detection unit. All individuals clinically evaluated in the early detection unit from 2012 to 2015 were included. A Central Psychiatric Research Register was searched for lifetime allocated diagnoses. Register search allowed a minimum of one-year follow-up after evaluation. To determine the predictive ability of the early detection unit, diagnoses allocated by the initial clinical evaluation were compared to later diagnoses in psychiatric services. Results In total 450 individuals were clinically evaluated in the early detection unit during a period of 3 years. Previously 174 (39 %) patients had been in contact with mental healthcare services, and 28 (6.2%) had previously been diagnosed with psychosis. During follow-up, a diagnosis of psychosis was allocated in 146 (32.4%) of all evaluated individuals. In the clinical assessment by the early detection unit 107 (73.3 %) were diagnosed with psychosis. In total 39 (14.7%) were assessed false negative for psychosis by the early detection unit, they were later diagnosed with psychosis in mental healthcare services. The majority of psychosis diagnoses was allocated within one year after assessment in the early detection unit and half of individuals who were diagnosed with psychosis was re-diagnosed with schizophrenia (n=73). The hazard ratio of receiving a diagnosis of psychosis subsequently in mental healthcare services in individuals diagnosed with psychosis by the early detection unit was 4.73 (95 % CI: 3.01 – 7.44, p < 0.0001) compared to individuals not found psychotic by the early detection unit. Discussion That more than a third of the clinical evaluated has previously been help-seeking in mental healthcare system demonstrates a source of delay in treatment, suggesting that contact to other parts of mental healthcare services can delay detection of psychosis. Of the individuals not evaluated cases of psychosis 15 % later received a diagnose of psychosis. This suggests that an important subgroup of the help-seeking individuals undergoes transition to psychosis after contact or that detection of psychosis has not been possible by evaluation in the early detection unit. In conclusion, attention should be made to all individuals self-referred to an early detection unit, as diagnoses of psychosis is seen in the majority within the first year after contact. Also in individuals not initially suspected of psychosis.


Proceedings ◽  
2018 ◽  
Vol 2 (13) ◽  
pp. 967 ◽  
Author(s):  
Georg Brunnhofer ◽  
Alexander Bergmann

In order to design an imaging unit of a novel holographic particle counter an aerosol particle model was developed to generate a virtual hologram plane of an aerosol volume of interest. The herein presented model combines the three essential components to help dimensioning a target detection unit: (i) an In-Line holography model with a reference light source and a basic transfer function of an imager to take into account imager size, pixel pitch and exposure time; (ii) an aerosol particle model with particles of variable count, size and spatial distribution; and (iii) the possibility to import fluid dynamics simulation data to simulate the particle flow in an arbitrary sampling volume.


Author(s):  
Markus Bader ◽  
Miguel Albero ◽  
Robert Sablatnig ◽  
Jose E. Simo ◽  
Gines Benet ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document