scholarly journals Optimal single procedure strategy of pulmonary vein isolation with cryoballoon or radiofrequency and non-pulmonary vein triggers ablation for non-paroxysmal atrial fibrillation

Author(s):  
Giichi Nitta ◽  
Junichi Nitta ◽  
Osamu Inaba ◽  
Akira Sato ◽  
Yukihiro Inamura ◽  
...  

Introduction: Limited data exist on pulmonary vein isolation (PVI) using cryoballoon (CB) or radiofrequency (RF) ablation and additional non-pulmonary vein triggers ablation for non-paroxysmal atrial fibrillation (non-PAF). The objective of this study was to assess the outcomes of first-stage catheter ablation for non-PAF patients. Methods and Results: Initial PVI was performed on 734 non-PAF patients (age: 64±10 years; male: 584) between September 2014 and June 2018 [315 (43%), CB ablation; 419 (57%), RF catheter]. A logistic regression model was used to match 257 pairs (514 patients) according to propensity scores (CB group or RF group). After PVI, additional non-PV triggers ablation was performed if induced by isoproterenol. We analyzed the clinical outcomes of both groups. The mean procedural time was significantly shorter in the CB group (125 [range, 89–165] min) than in the RF group (190 [160–224] min; P < 0.001). The 1-year Kaplan-Meier event rate revealed similar atrial fibrillation-free survival rate between the groups (CB: 77.9%, RF: 82.3%; log-rank P = 0.111). The additional ablation percentage for non-PV foci (CB: 39%, RF: 41%; P = 0.653) and the complications incidence (CB: 5%, RF: 4%; P = 0.670) were also similar. Conclusion: In non-PAF patients, PVI using CB or RF ablation and non-PV triggers ablation achieved comparable outcomes. The safety and efficacy of the combination strategy of PVI and non-PV triggers ablation was demonstrated.

2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
R Tilz ◽  
C L Lenz ◽  
P S Sommer ◽  
N Sawan ◽  
R Meyer-Saraei ◽  
...  

Abstract Background Based on the assumption of trigger elimination, pulmonary vein isolation (PVI) currently presents the gold standard of atrial fibrillation (AF) ablation. Recently, rapidly spinning rotors or focal impulse formation has been raised as a crucial sustaining mechanism of AF. Ablation of these rotors may potentially obviate the need for trigger elimination with PVI. Purpose This study sought to compare the safety and effectiveness of Focal Impulse and Rotor Modulation (FIRM) guided catheter ablation only with the gold standard of pulmonary vein isolation (PVI) in patients with paroxysmal AF. Methods This was a post-market, prospective, single-blinded, randomized, multi-center trial. Patients were enrolled at three centers and equally (1:1) randomized between those undergoing conventional RF ablation with PVI (PVI group) vs. those treated with FIRM-guided RF ablation without PVI (FIRM group). Data was collected at enrollment, procedure, and at 7-day, 3-month, 6-month, and 12-month follow-up visits. The study was closed early by the sponsor. At the time of study closure, any pending follow-up visits were waived. Results From February 2016 until February 2018, a total of 51 (out of a planned 170) patients (mean age 63±10.6 years, 57% male) were enrolled and randomized. Four patients withdrew from the study prior to treatment, resulting in 23 patients allocated to the FIRM group and 24 in the PVI group. Only 13 patients in the FIRM group and 11 patients in the PVI group completed the 12-month follow-up. Statistical analysis was not completed given the small number of patients. Single-procedure effectiveness (freedom from AF/atrial tachycardia recurrence after blanking period) was 52.9% (9/17) in the FIRM group and 85.7% (12/14) in the PVI group at 6 months; and 31.3% (5/16) in the FIRM group and 80% (8/10) in the PVI group at 12 months. Repeat procedures were performed in 45.8% (11/24) patients in the FIRM group and 7.4% (2/27) in the PVI group. The acute safety endpoint [freedom from procedure-related serious adverse events (SAE)] was achieved in 87% (20/23) of FIRM group patients and 100% (24/24) of PVI group patients. Procedure related SAEs occurred in three patients in the FIRM group: 1 femoral artery aneurysm and 2 injection site hematomas. No additional procedure-related SAEs were reported >7 days post-procedure. Conclusions These partial study effectiveness results reinforce the importance of PVI in paroxysmal atrial fibrillation patients and suggest that FIRM-guided ablation alone (without PVI) is not an effective strategy for treatment of paroxysmal AF in most patients. Further study is needed to understand the effectiveness of adding FIRM-guided ablation as an adjunct to PVI in this patient group. Acknowledgement/Funding Abbot


EP Europace ◽  
2019 ◽  
Vol 22 (3) ◽  
pp. 388-393 ◽  
Author(s):  
Marc Kottmaier ◽  
Miruna Popa ◽  
Felix Bourier ◽  
Tilko Reents ◽  
Jairo Cifuentes ◽  
...  

Abstract Aims Pulmonary vein isolation (PVI) using radiofrequency ablation (RFA) in patients with paroxysmal atrial fibrillation (PAF) is effective but hampered by pulmonary vein reconnection due to insufficient ablation lesions. High-power delivery over a short period of time (HPSD) in RFA is stated to create more efficient lesions. The aim of this study was to compare intraprocedural safety and outcome of HPSD ablation to conventional power settings in patients undergoing PVI for PAF. Methods and results We included 197 patients with PAF that were scheduled for PVI. An ablation protocol with 70 W and a duration cut-off of 7 s at the anterior left atrium (LA) and 5 s at the posterior LA (HPSD group; n = 97) was compared to a conventional power protocol with 30–40 W for 20–40 s (standard group; n = 100) in terms of periprocedural complications and a 1-year outcome. The HPSD group showed significantly less arrhythmia recurrence during 1-year follow-up with 83.1% of patients free from atrial fibrillation compared to 65.1% in the standard group (P &lt; 0.013). No pericardial tamponade, periprocedural thromboembolic complications, or atrio-oesophageal fistula occurred in either group. Mean radiofrequency time (12.4 ± 3.4 min vs. 35.6 ± 12.1 min) and procedural time (89.5 ± 23.9 min vs. 111.15 ± 27.9 min) were significantly shorter in the HPSD group compared to the standard group (both P &lt; 0.001). Conclusion High-power short-duration ablation demonstrated a comparable safety profile to conventional ablation. High-power short-duration ablation using 70 W for 5–7 s leads to significantly less arrhythmia recurrences after 1 year. Radiofrequency and procedural time were significantly shortened.


2021 ◽  
Vol 8 ◽  
Author(s):  
Xin Xie ◽  
Gang Yang ◽  
Xiaorong Li ◽  
Jinbo Yu ◽  
Fengxiang Zhang ◽  
...  

Background: Pulmonary vein isolation (PVI) is an effective strategy in the treatment of paroxysmal atrial fibrillation (PAF). Yet, there are limited data on additional ablation beyond PVI. In this study, we sought to assess the prevalence, predictors, and outcomes of additional ablation in PAF patients.Methods: A total of 537 consecutive patients with PAF were retrospectively evaluated for the index procedure. PVI was successfully conducted in all patients, after which electrophysiological study and drug provocation were performed, and additional ablations were delivered for concomitant arrhythmias, non-PV triggers, and low voltage zone (LVZ). The prevalence, predictors, and outcomes of additional ablation were analyzed.Results: Among 537 consecutive patients, 372 addition ablations were performed in 241 (44.88%) patients, including 252 (67.74%) concomitant arrhythmias in 198 (36.87%) patients, 56 (15.05%) non-PV triggers in 52 (9.68%) patients and 64 (17.20%) LVZ modification in 47 (8.75%) patients. Lower LVEF (OR = 0.937, p = 0.015), AF episode before procedure (OR = 2.990, p = 0.001), AF episode during procedure (OR = 1.998, p = 0.002) and AF episode induced after PVI (OR = 15.958, p &lt; 0.001) were independent predictors of additional ablation. Single-procedure free from atrial arrhythmias at 58.36 ± 7.12 months post-ablation was 70.48%.Conclusions: Additional ablations were common in patients with PAF for index procedure. Lower LVEF and AF episodes before, during the procedure, and induced after PVI predicts additional ablation.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
A Chikata ◽  
T Kato ◽  
K Ududa ◽  
S Fujita ◽  
K Otowa ◽  
...  

Abstract Introduction Pulmonary vein isolation (PVI) affects ganglionated plexi (GP) around the atrium, leading to a modification of the intrinsic cardiac autonomic system (ANS). In animal models, GP ablation has a potential risk of QT prolongation and ventricular arrhythmias. However, the impact of PVI on QT intervals in humans remains unclear. Purpose This study aims to evaluate the Impact of PVI on QT interval in patients with paroxysmal atrial fibrillation. Methods We analyzed consecutive 117 PAF patients for their first PVI procedures. 12-lead ECG was evaluated at baseline, 4 hr, day 1, 1 month, and 3 months after ablation. Only patients with sinus rhythm on 12-lead ECG at each evaluation point without antiarrhythmic drugs were included. Results Heart rate significantly increased at 4 hr, day 1, and 1 month. Raw QT interval prolonged at 4 hr (417.1±41.6 ms, P&lt;0.001) but shortened at day 1 (376.4±34.1 ms, P&lt;0.001), 1 month (382.2±31.5 ms, P&lt;0.001), and 3 months (385.1±32.8 ms, P&lt;0.001) compared to baseline (391.6±31.4 ms). Bazett- and Fridericia- corrected QTc intervals significantly prolonged at 4hr (Bazett: 430.8±27.9 ms, P&lt;0.001; Fridericia: 425.8±27.4 ms, P&lt;0.001), day1 (Bazett: 434.8±22.3 ms, P&lt;0.001; Fridericia: 414.1±23.7 ms, P&lt;0.001), 1M (Bazett: 434.8±22.3 ms, P&lt;0.001; Fridericia: 408.2±21.0 ms, P&lt;0.05), and 3M (Bazett: 420.1±21.8 ms, P&lt;0.001; Fridericia: 407.8±21.1 ms, P&lt;0.05) compared to baseline (Bazett: 404.9±25.2 ms; Fridericia: 400.0±22.6 ms). On the other hand, Framingham- and Hodges- corrected QTc interval significantly prolonged only at 4hr (Framingham: 424.1±26.6 ms, P&lt;0.001; Hodges: 426.8±28.4 ms, P&lt;0.001) and at day1 (Framingham: 412.3±29.3 ms, P&lt;0.01; Hodges: 410.6±40.2 ms, P&lt;0.05) compared to baseline (Framingham: 399.2±22.7 ms; Hodges: 400.7±22.8 ms). At 4 hr after ablation, raw QT and QTc of all formulas significantly prolonged than baseline. Raw QT and QTc prolongation at 4hr after ablation were more frequently observed in female patients. Multiple regression analysis revealed that female patient is a significant predictor of raw QT and QTc interval prolongation of all formulas 4hr after PVI. Conclusions Raw QT and QTc prolonged after PVI, especially in the acute phase. Female patient is a risk factor for QT prolongation in the acute phase after PVI. Funding Acknowledgement Type of funding source: None


EP Europace ◽  
2020 ◽  
Author(s):  
Michelle Lycke ◽  
Maria Kyriakopoulou ◽  
Milad El Haddad ◽  
Jean-Yves Wielandts ◽  
Gabriela Hilfiker ◽  
...  

Abstract Aims Catheter ablation of paroxysmal atrial fibrillation (AF) reduces AF recurrence, AF burden, and improves quality of life. Data on clinical and procedural predictors of arrhythmia recurrence are scarce and are flawed by the high rate of pulmonary vein reconnection evidenced during repeat procedures after pulmonary vein isolation (PVI). In this study, we identified clinical and procedural predictors for AF recurrence 1 year after CLOSE-guided PVI, as this strategy has been associated with an increased PVI durability. Methods and results Patients with paroxysmal AF, who received CLOSE-guided PVI and who participated in a prospective trial in our centre, were included in this study. Uni- and multivariate models were plotted to find clinical and procedural predictors for AF recurrence within 1 year. Three hundred twenty-five patients with a mean age of 63 years (CHA2DS2VASc 1 [1–3], left atrium diameter 41 ± 6 mm) were included. About 60.9% were male individuals. After 1 year, AF recurrence occurred in 10.5% of patients. In a binary logistic regression analysis, the diagnosis-to-ablation time (DAT) was found to be the strongest predictor of AF recurrence (P = 0.011). Diagnosis-to-ablation time ≥1 year was associated with a nearly two-fold increased risk for developing AF recurrence. Conclusion The DAT is the most important predictor of arrhythmia recurrence in low-risk patients treated with durable pulmonary vein isolation for paroxysmal AF. Whether reducing the DAT could improve long-term outcomes should be investigated in another trial.


Sign in / Sign up

Export Citation Format

Share Document