scholarly journals Shear Bond Strength of a New High Fluoride Release Glass Ionomer Adhesive

2008 ◽  
Vol 78 (1) ◽  
pp. 125-128 ◽  
Author(s):  
Samir E. Bishara ◽  
Manal Soliman ◽  
John F. Laffoon ◽  
John Warren

Abstract Objective: To determine the shear bond strength of a new resin glass ionomer adhesive with higher fluoride release properties when bonding orthodontic brackets. Materials and Methods: Sixty freshly extracted human molars were collected and stored in a solution of 0.1% (weight/volume) thymol. The teeth were cleaned and polished. The teeth were randomly separated into three groups according to the enamel conditioner/etchant and adhesive used. Group I: 20 teeth conditioned with 10% polyacrylic acid and brackets bonded with the new glass ionomer adhesive. Group II: 20 teeth conditioned with 37% phosphoric acid and brackets bonded with the new glass ionomer adhesive. Group III (control): 20 teeth etched with 37% phosphoric acid and brackets bonded with a composite adhesive. Results: The results of the analysis of variance comparing the three experimental groups (F = 10.294) indicated the presence of significant differences between the three groups (P = .0001). The shear bond strengths were significantly lower in the two groups bonded with the new glass ionomer adhesive whether conditioned with polyacrylic acid (x̄ = 3.2 ± 1.8 MPa) or phosphoric acid (x̄ = 2.3 ± 1.1 MPa), while the mean shear bond strength of the composite adhesive was 5.2 ± 2.9 MPa. Conclusions: Although the increased fluoride release from the new glass ionomer has the potential of decreasing decalcification around orthodontic brackets, the shear bond strength of the material is relatively low.

2007 ◽  
Vol 77 (6) ◽  
pp. 1096-1100 ◽  
Author(s):  
Hakan Türkkahraman ◽  
Necdet Adanir

Abstract Objective: To evaluate the effects of potassium nitrate and oxalate desensitizer agents on shear bond strengths of orthodontic brackets. Materials and Methods: Forty-five extracted human premolar teeth were randomly assigned to three groups of 15 each. UltraEZ potassium nitrate desensitizer was applied on teeth in the first group, while BisBlock oxalate desensitizer was applied on teeth in the second group. The third group served as a control. Orthodontic brackets were bonded with a light cure composite resin and cured with a halogen light. After bonding, the shear bond strength of the brackets was tested with a universal testing machine. Results: The highest shear bond strengths were measured in Group III. The shear bond strength in Groups I and II was significantly lower than in Group III (P < .001). Significant difference was also found between Group I and Group II (P < .01). Conclusions: Orthodontic brackets bonded to enamel treated with potassium nitrate and oxalate desensitizers showed significantly lower bond strengths than did brackets bonded to untreated enamel.


2002 ◽  
Vol 13 (3) ◽  
pp. 175-178 ◽  
Author(s):  
Maria Cristina Borsatto ◽  
Alma Blásida Elisaur Benitez Catirse ◽  
Regina Guenka Palma Dibb ◽  
Telma Nunes do Nascimento ◽  
Renata Andréa Salvitti de Sá Rocha ◽  
...  

The aim of this study was to evaluate the shear bond strength of a composite resin to dental enamel, using three different surface treatments. Fifteen sound third molars were randomly assigned to three groups. The mesial and distal surfaces were flattened and covered using adhesive tape with a central orifice delimiting the adhesion area (7.07 mm²). Group I, the enamel surface was conditioned with 37% phosphoric acid for 15 s; group II, the surface was treated using air abrasion with aluminum oxide; group III, the enamel surface was treated using an association of air abrasion with aluminum oxide and 37% phosphoric acid. The Single Bond (3M) adhesive system was applied and a Teflon matrix was placed and filled with composite resin Z-100 (3M) and light-cured. The shear bond strength test was performed with a universal testing machine. The acid etching technique and air abrasion with aluminum oxide associated with acid etching had the highest shear bond strength values. Data were subjected to statistical analysis using ANOVA and the Tukey test, and no statistically significant difference in shear bond strength was observed between group I (12.49 ± 2.85 MPa) and group III (12.59 ± 2.68 MPa). In contrast, both groups had statistically better shear bond strengths compared to group II (0.29 ± 0.56 MPa; p<0.05). Air abrasion with aluminum oxide does not substitute acid etching. The association of these methods to obtain adequate adhesion to the substrate is necessary.


2020 ◽  
Author(s):  
Purna Prasad Khanal ◽  
Basanta Kumar Shrestha ◽  
Rajiv Yadav ◽  
Sanjay Prasad Gupta

Abstract Background: Recycling the old or debonded bracket is one possible alternative to the replacement with new bracket. The aim of this study was to evaluate and compare the effect of different methods of recycling stainless steel orthodontic brackets on shear bond strength.Methods: One hundred twenty human premolars extracted for orthodontic purpose were randomly divided into four groups. Standard MBT (0.022”) brackets, (Leone co., Sesto, Florentine, Florence, Italy) were bonded on buccal surface of all samples with light cured adhesive primer Orthosol (Enlight, Ormco corp., USA) using LED curing unit for 10 seconds. Group I was assigned as control and the brackets of Group II, Group III and Group IV were subjected to recycling by flaming (Gas microtorch: RS Pro, Nozzle, MT 790) ,flaming with sandblasting (Bio-Art sandblaster; Rua Teotônio Vilela, Brazil) and flaming with ultrasonic cleaning (Ultrasonic cleaning unit ,Confident dental equipments Ltd, India) respectively. The recycled brackets were rebonded and final debonding of all brackets was done with universal testing machine (AG-IC/100 KN, Shimadzu, Japan) at a crosshead speed of 0.5mm/min and shear bond strength (MPa) was determined. The adhesive remnant index was evaluated by stereomicroscope at 10X magnification (Olympus corp., Japan). Results: The highest shear bond strength was obtained with Group I (10.35 ± 0.46 MPa), followed by Group III (9.36 ± 0.55 MPa), Group IV (5.97 ± 0.66 MPa) and the least value was obtained with Group II (4.30 ± 0.55 Mpa). Significant differences among the groups were detected by analysis of variance. Tukey post hoc multiple comparison test showed that the shear bond strength of each group was significantly different from one another (p < 0.001). The Chi-square showed statistically significant differences in the adhesive remnant index of the 4 groups (p < 0.001). Conclusions: Shear bond strength of new brackets was significantly higher than that of the recycled brackets. Among recycled brackets, flaming with sandblasting provided adequate shear bond strength, flaming with ultrasonic cleaning provided borderline value for clinical use while flaming alone led to significantly lower value.


Author(s):  
Elda PISANESCHI ◽  
Rubens Corte Real de CARVALHO ◽  
Edmir MATSON

The purpose of this study was to determine, through the shear bond strength of in vitro tests, that the type of glass-ionomer cements (conventional or hybrid) and dentin depth (superficial or deep) are factors that may influence the adhesion of these materials to the dentin structure. Specimens of two conventional glass-ionomer cements (Vidrion R® - SS White and Chelon Fil®- Espe) and a hybrid-glass ionomer cement (Vitremer® - 3M) were separated in groups and prepared for the shear bond strength test. The results submitted to statistical analysis were (all values are in MPa): Group I - Vidrion R - superficial dentin 1.97 (<FONT FACE="Symbol">±</FONT> 0.56); deep dentin 3.15 (<FONT FACE="Symbol">±</FONT> 1.51); Group II - Chelon Fil - superficial dentin 2.43 (<FONT FACE="Symbol">±</FONT> 1.43); deep dentin 3.21 (<FONT FACE="Symbol">±</FONT> 0.89); and Group III - Vitremer - superficial dentin 7.04 (<FONT FACE="Symbol">±</FONT> 2.04); deep dentin 10.30 (<FONT FACE="Symbol">±</FONT> 1.99). There were significant differences between dentin depth and type of materials


2021 ◽  
Vol 2021 ◽  
pp. 1-7
Author(s):  
Purna Prasad Khanal ◽  
Basanta Kumar Shrestha ◽  
Rajiv Yadav ◽  
Dr. Sanjay Prasad Gupta

Aim. The aim of this study was to evaluate and compare the effect of different methods of recycling stainless steel orthodontic brackets on shear bond strength. Methods. One hundred twenty human premolars extracted for orthodontic purpose were randomly divided into four groups. Standard MBT (0.022″) brackets were bonded on the buccal surface of all samples with light cured adhesive primers using an LED curing unit for 10 seconds. Group I was assigned as control, and the brackets of Group II, Group III, and Group IV were subjected to recycling by flaming, flaming with sandblasting, and flaming with ultrasonic cleaning, respectively. The recycled brackets were rebonded, and final debonding of all brackets was performed using a universal testing machine at a crosshead speed of 0.5 mm/min and shear bond strength was determined. Data were analyzed with descriptive statistics, ANOVA, and post hoc tests. The adhesive remnant index was evaluated using a stereomicroscope at 10X magnification. Results. The highest shear bond strength was obtained with Group I (10.35 ± 0.46 MPa), followed by Group III (9.36 ± 0.55 MPa) and Group IV (5.97 ± 0.66 MPa), and the least value was obtained with Group II (4.30 ± 0.55 Mpa). Significant differences among the groups were detected by analysis of variance. Tukey’s post hoc multiple comparison test showed that the shear bond strength of each group was significantly different from one another ( p < 0.001 ). Conclusions. Shear bond strength of new brackets was significantly higher than that of the recycled brackets. Among recycled brackets, flaming with sandblasting provided adequate shear bond strength, flaming with ultrasonic cleaning provided a borderline value for clinical use, and flaming alone led to a significantly lower value.


2021 ◽  
Author(s):  
Purna Prasad Khanal ◽  
Basanta Kumar Shrestha ◽  
Rajiv Yadav ◽  
Sanjay Prasad Gupta

Abstract Aim: The aim of this study was to evaluate and compare the effect of different methods of recycling stainless steel orthodontic brackets on shear bond strength.Methods: One hundred twenty human premolars extracted for orthodontic purpose were randomly divided into four groups. Standard MBT (0.022”) brackets were bonded on buccal surface of all samples with light cured adhesive primer using LED curing unit for 10 seconds. Group-I was assigned as control and the brackets of Group-II, Group-III and Group-IV were subjected to recycling by flaming, flaming with sandblasting and flaming with ultrasonic cleaning respectively. The recycled brackets were rebonded and final debonding of all brackets was done with universal testing machine at a crosshead speed of 0.5mm/min and shear bond strength was determined. Data were analyzed with descriptive statistics, ANOVA and post hoc test. The adhesive remnant index was evaluated by stereomicroscope at 10X magnification.Results: The highest shear bond strength was obtained with Group I (10.35 ± 0.46 MPa), followed by Group III (9.36 ± 0.55 MPa), Group IV (5.97 ± 0.66 MPa) and the least value was obtained with Group II (4.30 ± 0.55 Mpa). Significant differences among the groups were detected by analysis of variance. Tukey post hoc multiple comparison test showed that the shear bond strength of each group was significantly different from one another (p < 0.001). Conclusions: Shear bond strength of new brackets was significantly higher than that of the recycled brackets. Among recycled brackets, flaming with sandblasting provided adequate shear bond strength, flaming with ultrasonic cleaning provided borderline value for clinical use while flaming alone led to significantly lower value.


2010 ◽  
Vol 21 (6) ◽  
pp. 533-537 ◽  
Author(s):  
Ivan Toshio Maruo ◽  
Juliana Godoy-Bezerra ◽  
Armando Yukio Saga ◽  
Orlando Motohiro Tanaka ◽  
Hiroshi Maruo ◽  
...  

The aim of this study was to assess the influence of etching and light-curing time on the shear bond strength (SBS) and adhesive remnant index (ARI) of a resin-modified glass ionomer cement (RMGIC) upon debonding of orthodontic brackets. Sixty-eight bovine permanent incisors were obtained and embedded in acrylic resin. Edgewise metallic brackets were bonded to the teeth with Fuji Ortho LC RMGIC. The specimens were randomly assigned to 4 groups, using the following etching and light-curing times: G1: 10% polyacrylic acid and 40 s (control); G2: 37% phosphoric acid and 40 s; G3: 10% polyacrylic acid and 50 s; and G4: 37% phosphoric acid and 50 s. Shear test was performed at 0.5 mm/min and the ARI was assessed. G2 (3.6 ± 0.98 MPa) presented significantly higher (p<0.05) SBS than G1 (2.76 ± 0.86 MPa) and G4 (2.86 ± 0.68 MPa), and there was no statistically significant difference (p>0.05) between G2 and G3 (2.94 ± 0.67 MPa). ARI presented prevalence of scores 2 and 3 in all groups. RMGIC SBS enhanced with 37% phosphoric acid etching and 40 s light-curing time, but this did not occur when the light-curing time was increased, regardless of the acid used. RMGIC presented prevalence of failures at the adhesive/bracket interface.


2020 ◽  
pp. 1-11
Author(s):  
Anip K. Roy ◽  
Govind N. Prasad ◽  
Tushar V. Bhagat ◽  
Saurabh Chaturvedi ◽  
Vishwanath Gurumurthy ◽  
...  

BACKGROUND: The increased strength of zirconia has resulted in its widespread application in clinical dentistry. Nevertheless, the fracture of veneering porcelains remains one of the key reasons of failure. OBJECTIVE: The objective of this study was to compare and analyze the influence of surface conditioning methods on the core-veneer bond strength of zirconia restorations. METHODS: Thirty specimens of zirconia core with sizes 10 × 5 × 5 mm were layered with porcelain of sizes 5 × 3 × 3 mm. On the basis of different surface conditioning methods, four groups were made: Group I: abrasion with airborne alumina particles of 110 μm size, Group II: sandblasting with silica coated alumina particles of 50 μm in size, Group III (modified group): alteration with a coating of zirconia powder prior to sintering, and Group IV (control group): metal core specimens. The shear force of all specimens was tested using a universal testing machine with a 0.5 mm/min crosshead speed. One-way analysis of variance (ANOVA) and Tukey’s post hoc pair wise comparison (p= 0.05) were performed to analyze the shear bond strength. A scanning electron microscope was used to assess the fractured specimens. RESULTS: A statistically significant difference was noted between the groups. The mean value of shear bond strength was 40.25 MPa for Group I, 41.93 MPa for Group II, 48.08 MPa for Group III and 47.01 MPa for Group IV. CONCLUSIONS: The modified zirconia group and control group demonstrated a significantly higher mean bond strength than that of Group I, where airborne particle abrasion was used. The scanning electron microscope showed that cohesive fracture in the porcelain veneers was the main problem of failure in altered zirconia. The modified zirconia specimens in Group III demonstrated significantly improved values of shear bond strength.


2012 ◽  
Vol 17 (4) ◽  
pp. 1-7 ◽  
Author(s):  
Roberto Hideo Shimizu ◽  
Karlos Giovani Grando ◽  
Isabela Almeida Shimizu ◽  
Augusto Ricardo Andriguetto ◽  
Ana Cláudia Moreira Melo ◽  
...  

OBJECTIVE: This in vitro study was designed to evaluate the shear bond strength (SBS) of orthodontic metal brackets bonded by direct and indirect techniques. METHODS: Thirty healthy human maxillary premolar teeth were used. The teeth were divided into three groups of 10 teeth each: Group I - indirect bonding with SondhiTM Rapid-Set system (3M/Unitek), Group II - indirect bonding with TransbondTM XT adhesive system (3M/Unitek) and Group III - direct bonding with TransbondTM XT adhesive system (3M/Unitek). After bonding and obtaining the specimens for the study, the specimens were subjected to SBS testing in a universal testing machine (Emic, model DL-500). The Kolmogorov-Smirnov test was applied to ascertain that the data had a normal distribution and the Bartlett test to check whether there was homogeneity of variance. One-factor analysis of variance was performed and, subsequently, Tukey's test for paired means. A 5% significance level was adopted. RESULTS: The results of Group I were 67.6 (N) and 5.9 (MPa); Group II, 68.9 (N) and 6.1 (MPa) and Group III (control), 92.5 (N) and 8.1 (MPa). CONCLUSION: It can therefore be concluded that the means for Group III were significantly higher compared with Groups I and II in both Newton (N) and Megapascal (MPa) values. The means attained by the indirect bonding technique used in Groups I and II, however, exhibited no statistically significant differences.


2013 ◽  
Vol 4 (1) ◽  
pp. 6-16 ◽  
Author(s):  
BM Shivalinga ◽  
S Pradeep ◽  
Ravi Shanthraj ◽  
H Jyothi Kiran

ABSTRACT Aim To evaluate and compare shear bond strength (SBS) and debonding characters of the Transbond XT (BisGMA-based composite), Esthet-X flow (flowable composite), Filtek Z-350 (flowable composite). Materials and methods A total of 90 human premolars were divided into group I, Transbond XT (n = 30); group II, Esthet-X flow (n = 30) and group III, Filtek Z-350 (n = 30), the preadjusted edgewise stainless steel premolar brackets were bonded to evaluate the shear bond and debonding properties. Results The results of the statistical analysis comparing the three groups indicated no statistically significant differences between the groups. In general, the SBS with groups I and III exhibited similar bond strength with 11.58 ± 1.3 MPa and 11.07 ± 1.0 MPa respectively. Groups III exhibited least bond strength of 10.7 ± 2 MPa. In modified adhesive remnant index (ARI) the majority of bond failures occurred at enamel-adhesive interface or cohesive type failure in all the three groups. Groups II and III showed increased frequency of score 2, 4 and 5 compared to group I which showed increased frequency of score 0 and 1. Conclusion When considering the SBS and ARI scores obtained, flowable composites can be effectively applied to orthodontic bracket bonding. How to cite this article Pradeep S, Shanthraj R, Kiran HJ, Shivalinga BM. Comparative Evaluation of the Shear Bond Strength and Debonding Properties of a Conventional Composite and Flowable Composites used for Orthodontic Bracket Bonding. World J Dent 2013;4(1):6-16.


Sign in / Sign up

Export Citation Format

Share Document