scholarly journals One-year Adhesive Bond Durability to Coronal and Radicular Dentin Under Intrapulpal Pressure Simulation

2015 ◽  
Vol 40 (5) ◽  
pp. 540-547 ◽  
Author(s):  
HA El-Deeb ◽  
O Badran ◽  
EH Mobarak

SUMMARY Objective To evaluate the microtensile bond strength (μTBS) of different adhesives to coronal vs radicular dentin after one year of storage in artificial saliva and under intrapulpal pressure (IPP) simulation. Methods and Materials Roots of 36 freshly extracted premolars were sectioned 5 mm apical to the cemento-enamel junction and pulp tissue was removed. Buccal enamel and cementum were trimmed to obtain standardized flat dentin surfaces. Specimens were divided into three groups (n=12/group) according to the adhesive strategies utilized: a two-step etch-and-rinse adhesive; a two-step self-etch adhesive; and a single-step self-etch adhesive. Adhesives and resin composite were applied to coronal and radicular dentin while the specimens were subjected to IPP simulation. After curing, specimens were stored in artificial saliva at 37°C in a specially constructed incubator while the IPP was maintained for either 24 hours or one year prior to testing. Bonded specimens were sectioned into sticks with a cross section of 0.8 ± 0.01 mm2 and subjected to μTBS testing. Data were statistically analyzed using multi-way analysis of variance (ANOVA) with repeated measures; one-way ANOVA tests; and Bonferroni post hoc test (p<0.05). Failure modes were determined using a scanning electron microscope at 100× magnification. Results ANOVA results revealed a statistically significant effect for the adhesive strategy (p<0.001) and storage period (p<0.001) as well as for their interaction (p=0.024) on the μTBS. However, dentin substrate and its interactions revealed no significant effects. For both dentin substrates, the two-step self-etch adhesive revealed statistically significantly higher μTBS values than did the other two adhesives after 24 hours and one year of storage. After one-year storage, a significant decrease in bond strength values of all tested adhesives occurred with both dentin substrates. Modes of failure were mainly adhesive and mixed. Conclusions Adhesives were not sensitive to structural differences between coronal and radicular dentin even after one year of storage under IPP simulation. However, all tested adhesive systems strategies were sensitive to storage.

2013 ◽  
Vol 38 (4) ◽  
pp. 439-446 ◽  
Author(s):  
AA Ali ◽  
HA El Deeb ◽  
O Badran ◽  
EH Mobarak

SUMMARY Objective To evaluate the bond strength durability of a single-step self-etch adhesive to dentin pretreated with either ethanol-based chlorhexidine (ECHX) or water-based chlorhexidine (WCHX) after storage in artificial saliva and under intrapulpal pressure simulation (IPPS). Methods The occlusal enamel of 30 freshly extracted premolars was trimmed to expose midcoronal dentin. Roots were sectioned to expose the pulp chamber. Specimens were distributed over three groups (n=10) according to the dentin pretreatment used. In the first group, Adper Easy One (3M ESPE) was applied to the dentin surfaces according to the manufacturer's instructions (control group). In the second group, dentin was pretreated before bonding with 1 mL of 2% CHX diacetate dissolved in 100% ethanol (ECHX). The third group received the same pretreatment; however, CHX was dissolved in distilled water (WCHX). Pretreatment and bonding were carried out while the specimens were subjected to IPPS. Resin composite (Valux Plus, 3MESPE) buildups were made. After curing, specimens were stored in artificial saliva and under IPPS at 37°C in a specially constructed incubator (n=5/group) either for 24 hours or six months prior to testing. Thereafter, bonded specimens were sectioned into sticks with a cross section of 0.9 ± 0.01 mm2 and subjected to microtensile bond strength (μTBS) testing (n=25/subgroup) using a universal testing machine. Data were statistically analyzed using two-way analysis of variance (ANOVA) with repeated measures, one-way ANOVA , and Bonferroni post hoc tests (p≤0.05). Failure modes were determined using a scanning electron microscope. Results After 24 hours of storage, control and WCHX groups revealed significantly higher μTBS than the ECHX group. After six-month storage in artificial saliva and IPPS, only the WCHX group maintained its μTBS value. The predominant mode of failure was the mixed type, except for the ECHX group, which was mostly adhesive. Conclusion Pretreatment of the dentin with ECHX had a negative effect on bonding of the tested single-step self-etch adhesive; however, WCHX showed bond stability under IPPS.


2013 ◽  
Vol 24 (4) ◽  
pp. 335-339 ◽  
Author(s):  
Cesar Pomacondor-Hernandez ◽  
Alberto Nogueira de Gama Antunes ◽  
Vinicius di Hipolito ◽  
Mario Fernando de Goes

The purpose of this study was to evaluate the effect of replacing a component of the self-etch adhesive Adper Scotchbond SE (liquid A + liquid B) by 2% chlorhexidine (CHX) on bond strength to dentin after 1 day, 3 months or 6 months of water storage. Eight human teeth were sectioned to expose a flat dentin surface and were then randomly assigned to 2 groups. In the control group, the dentin surfaces were treated with the adhesive according to the manufacturer's instructions. In the experimental group, liquid A was replaced by 2% CHX. Next, a 6-mm-high resin composite block was incrementally built on the bonded surfaces. The restored teeth were then sectioned to produce stick-shaped specimens (cross-sectional area - 0.8 mm2). The microtensile bond strength (µTBS) was recorded, and the failure modes were assessed. Data were analyzed by two-way repeated measures ANOVA (α=0.05). Four additional teeth were processed in order to conduct a micromorphological analysis of the resin-dentin interface. The µTBS values did not significantly decrease after water storage in either the control or the experimental group, whose values did not differ significantly irrespective of storage time. The morphological aspect of the bonding interface appears not to have been affected by CHX. A higher incidence of cohesive failures within the adhesive and mixed failures (cohesive within adhesive and resin composite) was observed for both groups. It may be concluded that dentin pre-treatment with 2% CHX did not influence significantly the bonding performance of the evaluated adhesive.


2020 ◽  
Vol 14 (1) ◽  
pp. 408-415
Author(s):  
Isabella A. Gomes ◽  
Mário G. N. Gomes ◽  
Flávia L. B. Amaral ◽  
Fabiana M. G. França ◽  
Roberta T. Basting ◽  
...  

Objective: This study investigated whether different aging protocols have effects on the bond strength of total-etch and self-etch adhesive systems to dentin substrate. Methods: Molars were sectioned exposing the dentin, which was submitted to restorative procedures using two-step total-etch (ASB, Adper SingleBond2), two-step self-etch (CLF, Clearfil SEBond), or one-step self-etch (OPT, Optibond All-in-One) system and resin composite. The obtained blocks were sectioned to result in sticks to be submitted to bond strength and failure mode tests after 24h storage in distilled water (DW), or 180-day aging protocols in DW, artificial saliva (AS), citric acid (CA), or thermal cycling (TC). The types of failures were classified as adhesive, cohesive in dentin, cohesive in composite resin, and mixed. Data were analyzed using ANOVA followed by Tukey’s test (α=5%). The failure modes were descriptive under the relative frequencies form. Results: It was observed that ASB presented the higher bond strength(p<0.05), while CLF and OPT did not demonstrate differences between them(p>0.05) after 24h. The bond strength obtained with ASB significantly overcame that of OPT when stored in DW or AS for 180 days (p<0.001). In these storing mediums, ASB did not differ from CLF(p>0.05), while in CA or TC the values of CLF were significantly lower (p<0.001). In TC aging, the values presented by OPT did not differ from ASB(p>0.05), both of which had higher values than CLF(p<0.05). The predominant failure mode was adhesive. Conclusion: For the two-step total-etch and two-step self-etch adhesives, the influence of aging in AS and TC was equivalent to that of storage in DW. The most deleterious effects occurred in CA, a situation in which self-etch adhesives displayed worse performance than the conventional type.


Author(s):  
Omnia M. Sami ◽  
Essam A. Naguib ◽  
Rasha H. Afifi ◽  
Shaymaa M. Nagi

Abstract Objective Bonding to different dentin substrates influences resin composite restoration outcomes. This study investigated the influence of different adhesion protocols on the shear bond strength of universal adhesive systems to sound and artificial caries-affected dentin (CAD). Materials and Methods Occlusal enamel of 80 premolars were wet grinded to obtain flat midcoronal dentin. Specimens were equally divided according to the substrate condition: sound and CAD by subjecting to pH-cycling for 14 days. Each dentin substrate was bonded with the adhesive systems used in this study: Single Bond universal adhesive or Prime&Bond universal (applied either in etch-and-rinse or self-etch adhesion protocol). Adhesive systems were utilized according to manufacturers’ instructions, then resin composite was built up. Specimens were tested for shear bond strength. The data were analyzed by three-way analysis of variance, and failure modes were determined using stereomicroscope. Results There was no statistically significant difference between the two tested adhesive systems on artificially created CAD with different adhesion protocols. On sound dentin, Single Bond universal, either in the etch-and-rinse or self-etch adhesion protocols, revealed higher statistically significant shear bond strength mean values compared with CAD. Conclusion Single Bond universal adhesive in an etch-and-rinse adhesion protocol improved only bonding to sound dentin, while no added positive effect for the etching step with Prime&Bond universal adhesive was found when bonded to both sound and CAD substrates. The influence of CAD on the performance of the universal adhesives was material-dependent.


2013 ◽  
Vol 38 (5) ◽  
pp. E154-E165 ◽  
Author(s):  
E Mobarak ◽  
R Seyam

SUMMARY Objective The purpose of the study was to evaluate the nanoleakage and bond strength of different self adhesive systems cured with a modified-layering technique (MLT) to dentin of weakened roots. Methods Twenty-one maxillary incisors were decoronated and then root canals were instrumented and obturated with the cold lateral compaction technique. Weakened roots were simulated by flaring root canals until only 1 mm dentin thickness remained. Teeth were distributed into three groups. The canals were backfilled with Vertise Flow (VF group), a self-adhering system, following a modified-layering technique using two light-transmitting posts, sizes 6 and 3. DT Light Post size 2 was cemented using the same material. Remaining roots were prepared and cured in the same way as the VF group. However, in the TS/MF group, Clearfil Tri-S Bond (TS) adhesive and Clearfil Majesty Flow (MF) composite were used, while in the ED/PF group, ED primer II (ED)/Panavia F2.0 (PF) were used. After one week of storage, each root was sectioned to obtain six slices (two slices from each root third: coronal, middle and apical) of 0.9 ± 0.1 mm thickness. Interfacial nanoleakage expression was analyzed using a field emission scanning electron microscope (FEG-SEM), and the micro push-out bond strength (μPOBS) was measured at different root regions. Modes of failure were also determined using SEM. Data were statistically analyzed using two-way analysis of variance with repeated measures and Tukey post hoc test (p≤0.05). Results With MLT, all adhesive systems showed nanoleakage. For μPOBS, there was a statistically significant effect for adhesive systems (p&lt;0.001) but not for root region (p&lt;0.64) or for their interaction (p=0.99). Tukey post hoc test revealed that the bond strength of the VF group was significantly higher than the TS/MF and ED/PF groups for all root regions. Conclusion All of the tested self-adhesive systems cured using MLT had slight nanoleakage and were not sensitive to root regional differences. Self-adhering systems had higher bond strength than self-etch adhesives.


2016 ◽  
Vol 41 (3) ◽  
pp. 305-317 ◽  
Author(s):  
P Makishi ◽  
CB André ◽  
APA Ayres ◽  
AL Martins ◽  
M Giannini

SUMMARY Purpose: To investigate bond strength and nanoleakage expression of universal adhesives (UA) bonded to dentin and etched enamel. Methods: Extracted human third molars were sectioned and ground to obtain flat surfaces of dentin (n = 36) and enamel (n = 48). Dentin and etched enamel surfaces were bonded with one of two UAs, All-Bond Universal (ABU) or Scotchbond Universal (SBU); or a two-step self-etching adhesive, Clearfil SE Bond (CSEB). A hydrophobic bonding resin, Adper Scotchbond Multi-Purpose Bond (ASMP Bond) was applied only on etched enamel. Following each bonding procedure, resin composite blocks were built up incrementally. The specimens were sectioned and subjected to microtensile bond strength (MTBS) testing after 24 hours or one year water storage, or immersed into ammoniacal silver nitrate solution after aging with 10,000 thermocycles and observed using scanning electron microscopy. The percentage distribution of silver particles at the adhesive/tooth interface was calculated using digital image-analysis software. Results: The MTBS (CSEB = SBU &gt; ABU, for dentin; and CSEB &gt; ABU = SBU = ASMP Bond, for etched enamel) differed significantly between the adhesives after 24 hours. After one year, MTBS values were reduced significantly within the same adhesive for both substrates (analysis of variance, Bonferroni post hoc, p&lt;0.05), and no significant differences were found among the adhesives for etched enamel. Silver particles could be detected within the adhesive/dentin interface of all specimens tested. Kruskal-Wallis mean ranks for nanoleakage in ABU, SBU, and CSEB were 16.9, 18.5 and 11, respectively (p&gt;0.05). Conclusions: In the short term, MTBS values were material and dental-substrate dependent. After aging, a decrease in bonding effectiveness was observed in all materials, with nanoleakage at the adhesive/dentin interface. The bonding of the UAs was equal or inferior to that of the conventional restorative systems when applied to either substrate and after either storage period.


2018 ◽  
Vol 2018 ◽  
pp. 1-8 ◽  
Author(s):  
Katrin Zumstein ◽  
Anne Peutzfeldt ◽  
Adrian Lussi ◽  
Simon Flury

This study investigated the effect of SnCl2/AmF pretreatment on short- and long-term bond strength of resin composite to eroded dentin mediated by two self-etch, MDP-containing adhesive systems. 184 dentin specimens were produced from extracted human molars. Half the specimens (n=92) were artificially eroded, and half were left untreated. For both substrates, half the specimens were pretreated with SnCl2/AmF, and half were left untreated. The specimens were treated with Clearfil SE Bond or Scotchbond Universal prior to application of resin composite. Microtensile bond strength (μTBS) was measured after 24 h or 1 year. Failure mode was detected and EDX was performed. μTBS results were statistically analyzed (α=0.05). μTBS was significantly influenced by the dentin substrate (eroded < noneroded dentin) and storage time (24 h > 1 year; p<0.0001) but not by pretreatment with SnCl2/AmF or adhesive system. The predominant failure mode was adhesive failure at the dentin-adhesive interface. The content of Sn was generally below detection limit. Pretreatment with SnCl2/AmF did not influence short- and long-term bond strength to eroded dentin. Bond strength was reduced after storage for one year, was lower to eroded dentin than to noneroded dentin, and was similar for the two adhesive systems.


2017 ◽  
Vol 20 (4) ◽  
pp. 55
Author(s):  
Rafael Avellar de Carvalho Nunes ◽  
Flávia Lucisano Botelho do Amaral ◽  
Fabiana Mantovani Gomes França ◽  
Cecilia Pedroso Turssi ◽  
Roberta Tarkany Basting

<p class="Corpo"><strong>Objective</strong>: the aim of the present study was to evaluate the influence of adding different concentrations of chitosan to an experimental two-step etch-and-rinse adhesive system on the bond strength and failure mode to dentin. <strong>Material</strong> <strong>and</strong> <strong>Methods</strong>: thirty-two flat dentin surfaces were obtained from extracted human third molars and divided into four groups  (n=8) for application of the adhesive systems: AD - conventional two-step adhesive system (Adper Single Bond 2); EXP – experimental two-step etch-and-rinse adhesive system; Chi0.2% - EXP with addition of 0.2% Chitosan; Chi0.5% - EXP with addition of 0.5% Chitosan. Resin composite build-ups were made and the composite/dentin specimens were sectioned to obtain rectangular beams with a bond area of approximately 1mm<sup>2</sup>. After 24 hours, the sticks were submitted to microtensile bond strength tests in a universal test machine. The fracture pattern was evaluated under a stereoscopic loupe at 40X magnification. <strong>Results</strong>: one-way analysis of variance showed that the type of adhesive system had no significant effect on the bond strength values (p = 0.142), showing the mean bond strength values (standard deviation), in MPa, for the groups as follows: AD=20.1 (5.4); EXP=16.6 (2.3); Chi0.2%=16.1 (2.8); Chi0.5%=16.9 (2.3). In all the groups there was predominance of cohesive fractures in dentin, representing 68 to 82% of the failure modes. <strong>Conclusion</strong>: the addition of 0.2 or 0.5% of chitosan had no influence on the bond strength and failure mode of an experimental two-step etch-and-rinse adhesive system to dentin.</p><p class="Corpo"><strong>Keywords</strong></p><p class="Corpo">Chitosan; Dental Adhesives; Failure Mode; Microtensile Bond Strength.</p>


2019 ◽  
Vol 30 (5) ◽  
pp. 467-475 ◽  
Author(s):  
Gabriela Cardoso de Cardoso ◽  
Leina Nakanishi ◽  
Cristina Pereira Isolan ◽  
Patrícia dos Santos Jardim ◽  
Rafael Ratto de Moraes

Abstract This study evaluated the immediate and 6-month dentin bond strength of universal adhesives used in etch-and-rinse or self-etch bonding strategies. The adhesives tested were Ambar Universal, G-Bond, Single Bond Universal, Tetric N-Bond Universal, and Ybond Universal. Gold standard adhesives (Scotchbond Multipurpose Plus and Clearfil SE Bond) were controls. Microtensile dentin bond strength (n=5 teeth), pH, and C=C conversion (n=3) were evaluated. Data were analyzed at α=0.05. All adhesives showed differences in pH. Ybond had intermediately strong aggressiveness, whereas the others were ultra-mild. The C=C conversion was different in most adhesives. In the etch-and-rinse strategy, all adhesives showed similar results generally except for G-Bond, which had lower bond strength than most adhesives. G-Bond and Tetric-N-Bond showed lower bond strengths after 6 months compared with 24 h, whereas the other adhesives had stable dentin bonds. In the self-etch strategy, G-Bond had lower bond strength than most adhesives. After 6 months, Ambar was the only adhesive showing lower dentin bond strength compared with 24 h. Most adhesives had discreet drops in bond strength during aging when used in the self-etch strategy. The failure modes were also material dependent, with a general pattern of increased adhesive and/or pre-testing failures after storage. In conclusion, the bonding performance of universal adhesives to dentin is material dependent. Most adhesives had stable dentin bonds with results comparable to the gold standard materials, particularly when applied in the self-etch mode. In general, it seems the use of universal adhesives in dentin should not be preceded by phosphoric acid etching.


2020 ◽  
Vol 2020 ◽  
pp. 1-7
Author(s):  
Ruba M. Mustafa ◽  
Suhad J. Al-Nasrawi ◽  
Abtesam I. Aljdaimi

Biodentine is a calcium silicate cement (CSC) that has been broadly applied in vital pulp therapy. The quality of the Biodentine-composite bond has a significant effect on the longevity of the definitive restoration. The aim of this study is to investigate the shear bond strength (SBS) between Biodentine and composite restoration at different maturation times of Biodentine aged in artificial saliva. Fifteen Biodentine discs were allocated into three groups (n = 5) based on the timeframe of performance of composite restoration: immediate (after 12  min), after 14 days, and after 28 days of Biodentine maturation. Total etch and rinse adhesive system and bulk-fill regular resin composite were used. The shear bond strength and the failure pattern were assessed. One-way ANOVA with the Bonferroni post hoc test was applied for statistical analysis at p < 0.05 . The highest (32.47 ± 8.18 MPa) and the lowest (4.08 ± 0.81 MPa) SBS values were recorded for 14 days and 12 min groups, respectively. Significant statistical differences were reported among the groups, and a high statistically significant difference was found between the immediate group and the other groups. Adhesive failure patterns were evident in all groups. More clinically acceptable bond strength between the Biodentine and overlaid composite restoration is at 14 days after Biodentine maturation. Delaying the coverage of Biodentine later than 14 days may significantly reduce the SBS. Using the artificial saliva as an aging medium may affect the SBS between Biodentine and composite material.


Sign in / Sign up

Export Citation Format

Share Document