scholarly journals ASSESSMENT OF ENERGY PERFORMANCE AND THERMAL BEHAVIOR OF A SINGLE-FAMILY RESIDENTIAL BUILDING

2019 ◽  
Vol 4 (1) ◽  
pp. 21-42
Author(s):  
Ayse Zelal Tugrul ◽  
2020 ◽  
Vol 197 ◽  
pp. 02002
Author(s):  
Ilaria Marotta ◽  
Francesco Guarino ◽  
Maurizio Cellura ◽  
Sonia Longo

Since the building sector is responsible for 40% of the world’s electricity demand, it is essential to act on it in order to reduce emissions of climate change gases on a global scale, as expressed also in the latest directive on the energy performance of buildings. A design approach that focuses on the energy flexibility of buildings can contribute to the improvement of its energy-environmental performances. In this context, the objective of the study is the analysis of the energy performance of a residential building in Sicily and the definition of strategies aimed at increasing its energy flexibility. In particular, the case study is a 631 m2 single-family house, modeled and simulated in TRNSYS environment. The approach involves the development of scenarios to reduce operating costs and CO2 emissions during the use phase of the building. Rule Based Control algorithms are implemented. The flexible control reacts to a price or emission signal, by modulating the heating set-point accordingly. The results highlighted significant increases in energy flexibility. The economic algorithm achieves savings of 21.46%, accompanied by a 15% reduction in emissions. The environmental algorithm allows to reduce CO2 emissions by about 30%. The economic impact is positive, with a 17.58% reduction in costs.


2018 ◽  
Vol 49 ◽  
pp. 00049
Author(s):  
Hanna Jędrzejuk

The paper presents an assessment of the possibility of using solar energy for heating a selected residential building. The influence of the thermal insulation standard of the outer casing and the air tightness of the building on technical solutions with conventional heat sources and a solar energy system was analysed. In Polish climate conditions, especially in November and December, the availability of solar energy is usually insufficient in relation to heating needs. Therefore, it is necessary to store heat when it is to be used for heating. Monthly and yearly periods of heat storage have been considered. The influence of the use of solar radiation energy on the change in the energy performance of the building and on the reduction of carbon dioxide emissions was determined. Characteristics of heating systems and devices [9] as well as generally available meteorological data [5] were used for energy calculations.


Proceedings ◽  
2020 ◽  
Vol 63 (1) ◽  
pp. 41
Author(s):  
Hanae El Fakiri ◽  
Lahoucine Ouhsaine ◽  
Abdelmajid El Bouardi

The thermal dynamic behavior of buildings represents an important aspect of the energy efficiency and thermal comfort of the indoor environment. For this, phase change material (PCM) wallboards integrated into building envelopes play an important role in stabilizing the temperature of the human comfort condition. This article provides an assessment of the thermal behavior of a “bi-zone” building cell, which was built based on high-energy performance (HEP) standards and heated by a solar water heater system through a hydronic circuit. The current study is based on studying the dynamic thermal behavior, with and without implantation of PCMs on envelope structure, using a simplified modeling approach. The evolution of the average air temperature was first evaluated as a major indicator of thermal comfort. Then, an evaluation of the thermal behavior’s dynamic profile was carried out in this study, which allowed for the determination of the PCM rate anticipation in the thermal comfort of the building cell.


2020 ◽  
Vol 13 (1) ◽  
pp. 235
Author(s):  
Fernando Martín-Consuegra ◽  
Fernando de Frutos ◽  
Ignacio Oteiza ◽  
Carmen Alonso ◽  
Borja Frutos

This study quantified the improvement in energy efficiency following passive renovation of the thermal envelope in highly inefficient residential complexes on the outskirts of the city of Madrid. A case study was conducted of a single-family terrace housing, representative of the smallest size subsidized dwellings built in Spain for workers in the nineteen fifties and sixties. Two units of similar characteristics, one in its original state and the other renovated, were analyzed in detail against their urban setting with an experimental method proposed hereunder for simplified, minimal monitoring. The dwellings were compared on the grounds of indoor environment quality parameters recorded over a period covering both winter and summer months. That information was supplemented with an analysis of the energy consumption metered. The result was a low-cost, reasonably accurate measure of the improvements gained in the renovated unit. The monitoring output data were entered in a theoretical energy efficiency model for the entire neighborhood to obtain an estimate of the potential for energy savings if the entire urban complex were renovated.


Buildings ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 59
Author(s):  
Abraham Yezioro ◽  
Isaac Guedi Capeluto

Improving the energy efficiency of existing and new buildings is an important step towards achieving more sustainable environments. There are various methods for grading buildings that are required according to regulations in different places for green building certification. However, in new buildings, these rating systems are usually implemented at late design stages due to their complexity and lack of integration in the architectural design process, thus limiting the available options for improving their performance. In this paper, the model ENERGYui used for design and rating buildings in Israel is presented. One of its main advantages is that it can be used at any design stage, including the early ones. It requires information that is available at each stage only, as the additional necessary information is supplemented by the model. In this way, architects can design buildings in a way where they are aware of each design decision and its impact on their energy performance, while testing different design directions. ENERGYui rates the energy performance of each basic unit, as well as the entire building. The use of the model is demonstrated in two different scenarios: an office building in which basic architectural features such as form and orientation are tested from the very beginning, and a residential building in which the intervention focuses on its envelope, highlighting the possibilities of improving their design during the whole design process.


2020 ◽  
Vol 10 (13) ◽  
pp. 4489
Author(s):  
Zakaria Che Muda ◽  
Payam Shafigh ◽  
Norhayati Binti Mahyuddin ◽  
Samad M.E. Sepasgozar ◽  
Salmia Beddu ◽  
...  

The increasing need for eco-friendly green building and creative passive design technology in response to climatic change and global warming issues will continue. However, the need to preserve and sustain the natural environment is also crucial. A building envelope plays a pivotal role in areas where the greatest heat and energy loss often occur. Investment for the passive design aspect of building envelopes is essential to address CO 2 emission. This research aims to explore the suitability of using integral-monolithic structural insulation fibre-reinforced lightweight aggregate concrete (LWAC) without additional insulation as a building envelope material in a high-rise residential building in the different climatic zones of the world. Polypropylene and steel fibres in different dosages were used in a structural grade expanded clay lightweight aggregate concrete. Physical and thermal properties of fibre reinforced structural LWAC, normal weight concrete (NWC) and bricks were measured in the lab. The Autodesk@Revit-GBS simulation program was implemented to simulate the energy consumption of a 29-storey residential building with shear wall structural system using the proposed fibre-reinforced LWAC materials. Results showed that energy savings between 3.2% and 14.8% were incurred in buildings using the fibre-reinforced LWAC across various climatic regions as compared with traditional NWC and sand-cement brick and clay brick walls. In conclusion, fibre-reinforced LWAC in hot-humid tropical and temperate Mediterranean climates meet the certified Green Building Index (GBI) requirements of less than 150 kW∙h∙m−2. However, in extreme climatic conditions of sub-arctic and hot semi-arid desert climates, a thicker wall or additional insulation is required to meet the certified green building requirements. Hence, the energy-saving measure is influenced largely by the use of fibre-reinforced LWAC as a building envelope material rather than because of building orientation.


2019 ◽  
Vol 111 ◽  
pp. 03003
Author(s):  
Kaoutar Zeghari ◽  
Hasna Louahlia ◽  
Malo Leguern ◽  
Mohamed Boutouil ◽  
Hamid Gualous ◽  
...  

The appliance of sustainable development approach in building has urged construction industry to adopt proper measurements to protect environment and reduce residential building energy consumption and CO2 emissions. Thus, an increasing interest in alternative building materials has developed including the use of bio-based materials such as cob which is studied in this paper. In the previous work, many experimental and numerical studies have been carried out to characterize thermal behaviour of earth buildings, reduce its thermal conductivity and water content. In this paper, an experimental study is carried out to determine the thermal properties and energy performance of cob building. Cob samples within different soil and fiber contents are studied using an experimental set up instrumented with flux meters and micro-thermocouples in order to evaluate the local heat flux and thermal conductivity during stationary regime. The results are analysed and compared to deduce the performant mixes in terms of thermal behaviour while respecting the French thermal regulation. A static thermal simulation based on RT 2012 calculation method (the official French calculation method for the energy performance of new residential and commercial buildings according to France thermal regulation) is used to compare energy performance between conventional and cob building using the French climate data base .


Sign in / Sign up

Export Citation Format

Share Document