The article describes the development, fabrication, and test results of a double pancake сoil made using second-generation high-temperature superconductors (HTSC-2G). The HTSC-2G coil is the key element of the cryomagnetic system intended for use as part of an experimental research setup for remotely controlling the expression of neurons by means of constant and low-frequency (up to 100 Hz) magnetic field. This project is a continuation of works [1] carried out on the integrated topic “Electronic Components and Neuromorphic Ccontrol Systems”, which includes, as a constituent part, the development and fabrication of an HTSC-2G cryomagnetic system for studying neuron activity under the effect of external magnetic field. A distinctive feature of the project is the use of a cryomagnetic system with a low energy consumption achieved owing to the use of modern HTSC materials. This will open the possibility to continuously observe the object under study from the start of its exposure to magnetic field to the occurrence of reaction signs. The technology for winding a double pancake HTSC-2G coil is developed and described. For making the coil, an HTSC-2G wire in polyamide varnish insulation was used. The technology of making inner junctions in double pancake HTSC-2G coils with a transition resistance of less than 120 nΩ at 77 K has been developed and successfully tried out. The results from preliminary tests of the HTSC-2G coil in liquid nitrogen are presented.

2021 ◽  
Author(s):  
Masakazu Iwasaka

AbstractA large number of living creatures are able to use environmental light effectively as a biological display. The biological structural colors are very attractive not only within the coloring species but also to humans. However, the detailed function of bio-reflectors, which constitute the structural color with respect to communication, remains unknown. Atherinomorus lacunosus has alignments of iridophore spots on its dorsal part. Here it is found that a spot with a diameter of approximately 0.1 mm causes a rhythmic blinking of light owing to rapid reflection changes in iridophores existing inside the spot. The iridophores contain reflecting particles which show similar rotational responses to magnetic field under a light exposure. The speed of the intensity change of light at a frequency of approximately 1 Hz is proposed to be controlled by the nervous system of A. lacunosus. This kind of passive illumination may contribute to the development of a new optical device with low energy consumption.


2014 ◽  
Vol 675-677 ◽  
pp. 90-93
Author(s):  
Li Li Lu ◽  
Dong Wei Li ◽  
Xiang Dong Wei ◽  
Chan Juan Liao ◽  
Jiao Lian Jiang ◽  
...  

In view of the pollution of heavy metals in tailings of mining area, considering some metal recycling, in this paper, the method which was environmental friendly, mild reaction, short process, low energy consumption was applied to leaching As and Cd in tailings. Before leaching, Static Magnetic Field was used to deal with leach liquor, to research the effect of leaching rate for As and Cd. The results showed that under the conditions of pulp density 5%, inoculum 10%, leaching temperature 30°C, pH 2.0, magnetic induction intensity separately were 2mT , 5mT , 8mT and 11mT, the leaching rates of As and Cd were increased respectively about 8% and 2%. Besides, magnetic induction intensity also effected. The best magnetic induction intensity in bioleaching of As and Cd were respectively 2mT and 8mT.


2022 ◽  
Vol 92 (2) ◽  
pp. 250
Author(s):  
Д.Н. Диев ◽  
И.А. Ковалев ◽  
М.Н. Макаренко ◽  
А.В. Наумов ◽  
А.В. Поляков ◽  
...  

The paper describes a high-temperature superconducting magnetic system (HTS SMS) to equip an experimental stand intended for neuron activity researches under constant and low-frequency magnetic fields up to 1 T. The design of the magnetic system together with its electromagnetic and cryogenic parameters is briefly discussed. The test results of the preliminary experiments conducted in liquid nitrogen at 77 K for two interchangeable magnets are given. The first magnet was manufactured in the form of a double pancake coil wound with 4 mm high HTS tape. The second magnet was made of pure copper wire with no frame and was impregnated with a thermally conducting epoxy resin. The advantages of the HTS pancake coil were demonstrated in comparison with the cryo-resistive solenoid. Low energy consumption of the HTS magnetic system will allow conducting continuous non-invasive monitoring of biological objects in a magnetic field.


Author(s):  
G. G. Hembree ◽  
Luo Chuan Hong ◽  
P.A. Bennett ◽  
J.A. Venables

A new field emission scanning transmission electron microscope has been constructed for the NSF HREM facility at Arizona State University. The microscope is to be used for studies of surfaces, and incorporates several surface-related features, including provision for analysis of secondary and Auger electrons; these electrons are collected through the objective lens from either side of the sample, using the parallelizing action of the magnetic field. This collimates all the low energy electrons, which spiral in the high magnetic field. Given an initial field Bi∼1T, and a final (parallelizing) field Bf∼0.01T, all electrons emerge into a cone of semi-angle θf≤6°. The main practical problem in the way of using this well collimated beam of low energy (0-2keV) electrons is that it is travelling along the path of the (100keV) probing electron beam. To collect and analyze them, they must be deflected off the beam path with minimal effect on the probe position.


Sign in / Sign up

Export Citation Format

Share Document