scholarly journals The Effect of External Blinds on Selected Parameters of the Indoor Environment of an office Building

2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Pavol Ďurica ◽  
Peter Barňák

Abstract This contribution focuses on the indoor environmental quality in summer due to overheating of the interior of a west-facing office, since buildings designed in passive standard do not have a problem in the winter heating season but have a problem with cooling in the summer season. Therefore, the article focuses on the effect of external blinds on the indoor environmental parameters.

2016 ◽  
Vol 26 (6) ◽  
pp. 813-827 ◽  
Author(s):  
Marina Laskari ◽  
Stavroula Karatasou ◽  
Mat Santamouris

This paper presents the methodology for the calculation of an indoor environmental quality indicator for residential buildings. The ‘Dwelling Environmental Quality Index’ has been developed with the purpose of assisting both households and property managers to identify potential problems with the indoor environment whilst ensuring that indoor environmental quality is not compromised in favour of energy saving. Based on the combined effect of three simple and commonly measured indoor environmental parameters – air temperature, relative humidity and CO2 concentrations; the index reflects in a single value the quality of indoor environmental conditions for the monitored period, in compliance with the European standard EN15251:2007. The application of the Dwelling Environmental Quality Index in single dwellings and in building blocks is demonstrated. The usability of the index as a communication and management tool for individual households and property managers is also demonstrated.


2018 ◽  
Vol 28 (4) ◽  
pp. 470-478 ◽  
Author(s):  
Kwok Wai Mui ◽  
Tsz Wun Tsang ◽  
Ling Tim Wong ◽  
Yuen Ping William Yu

This study investigates the indoor environmental quality (IEQ) responses from occupants living in very small residential units that are unique to Hong Kong. Through the changes in environmental parameters, including thermal, indoor air quality, visual and aural, the study demonstrates that the overall IEQ acceptance in these units is different from the one in general residential building environments. Results show that occupants of these units are more sensitive to warmth and operative temperature change as compared to occupants of general residential buildings. A small variation of thermal acceptance suggests that the small unit occupants have already developed certain degree of tolerance to hot conditions. The adaptation to the reality of a hot environment is also reflected in the overall IEQ acceptance. It is believed that very small space residents have developed tolerance and adaptation to an unchangeable reality, changing environmental conditions does not necessarily alter their acceptance of individual IEQ aspects and overall IEQ.


2019 ◽  
Vol 282 ◽  
pp. 02071
Author(s):  
Catarina F. T. Ribeiro ◽  
Nuno M. M. Ramos ◽  
Inês Flores-Colen

Throughout history, it has always been recognised that the spaces in-between in dwellings have the advantage of working as environmental buffer spaces. The aim of this paper is to provide a literature review of the different spaces in-between in dwellings – balconies, shaded balconies and glazed balconies - and their impacts on comfort and on energy performance. The effects of the spaces in-between depend on their design, on the characteristics of the buildings and on the surroundings. They have important impacts on the four factors that contribute to the indoor environmental quality: thermal comfort, lighting comfort, acoustic comfort and indoor air quality. These factors are interrelated and the lack of balance between them can lead to poor indoor environmental conditions and to excessive energy consumption. Based on the review, a synthesis of the key environmental parameters that can be used as indicators for those factors is established. The impacts of spaces in-between on the factors and sub-factors of indoor environment are defined, considering different climatic regions. A holistic approach that conciliates all the above-mentioned factors should be a contribution to the design of spaces in-between in both new construction and rehabilitation projects, in order to achieve better indoor environment with minimum energy consumption.


Buildings ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 233
Author(s):  
Ágnes Borsos ◽  
Erzsébet Szeréna Zoltán ◽  
Éva Pozsgai ◽  
Balázs Cakó ◽  
Gabriella Medvegy ◽  
...  

Previous studies have shown that indoor environmental quality (IEQ) parameters may have a considerable effect on office employees’ comfort, health and performance. Therefore, we initiated a research program to help occupants identify IEQ parameters they perceive as risk factors for their health in an office and enhance their comfort levels in an office environment. Since we assumed that office employees might have different indoor environmental quality expectations related to their work area and that these differences could be measured, our objective was to develop an office ‘comfort map’ based on occupants’ individual IEQ preferences. Thus, the goal of the comfort map would be to help tailor office spaces to their occupants’ health and comfort expectations. The comfort survey was developed to assess the comfort-related opinions of the occupants, based on IEQ parameters (visual comfort, acoustic comfort, air quality and thermal comfort) of a chosen open-plan office building. The survey also assessed the degree to which the given IEQ parameter was considered a health risk factor by occupants or caused a negative comfort sensation for them. The survey was filled in by 216 occupants. The answers were then analyzed with the help of a frequency table depicting relative frequency. The measurements of IEQ parameters took place in an open-plan office in the chosen office building (a Hungarian subsidiary’s office building belonging to an international company in Budapest). The occupants had different opinions regarding the perceived effects of the IEQ parameters on their health and comfort. Almost two-thirds of the respondents (64.8%) were dissatisfied with the adjustability of the noises and sounds IEQ parameter at their workstation. Furthermore, half of the respondents (50.1%) were dissatisfied with the adjustability of ventilation. Most of the occupants (45.8%) considered noises and sounds as the IEQ parameter that had a negative effect on their health. There were also IEQ differences between different areas of the office space. Based on these results, a comfort map was developed for the office. The comfort map contains information about the IEQ characteristics of each workstation by depicting the thermal comfort, carbon dioxide, visual comfort and acoustic comfort characteristics of a given workstation on a relative scale. Based on the thermal, air, acoustic, and lighting differences between the workstations, occupants can select their preferred workstations when a desk-sharing system works. Although still in its pilot phase, the comfort map could increase the chances for office employees to find the workstation best suited to their IEQ expectations. This could improve occupants’ overall comfort level, which could in turn enhance occupants’ productivity and mental as well as physical health.


Sensors ◽  
2018 ◽  
Vol 18 (12) ◽  
pp. 4345 ◽  
Author(s):  
Alvaro Ortiz Perez ◽  
Benedikt Bierer ◽  
Louisa Scholz ◽  
Jürgen Wöllenstein ◽  
Stefan Palzer

Schools are amongst the most densely occupied indoor areas and at the same time children and young adults are the most vulnerable group with respect to adverse health effects as a result of poor environmental conditions. Health, performance and well-being of pupils crucially depend on indoor environmental quality (IEQ) of which air quality and thermal comfort are central pillars. This makes the monitoring and control of environmental parameters in classes important. At the same time most school buildings do neither feature automated, intelligent heating, ventilation, and air conditioning (HVAC) systems nor suitable IEQ monitoring systems. In this contribution, we therefore investigate the capabilities of a novel wireless gas sensor network to determine carbon dioxide concentrations, along with temperature and humidity. The use of a photoacoustic detector enables the construction of long-term stable, miniaturized, LED-based non-dispersive infrared absorption spectrometers without the use of a reference channel. The data of the sensor nodes is transmitted via a Z-Wave protocol to a central gateway, which in turn sends the data to a web-based platform for online analysis. The results show that it is difficult to maintain adequate IEQ levels in class rooms even when ventilating frequently and that individual monitoring and control of rooms is necessary to combine energy savings and good IEQ.


2017 ◽  
Vol 41 (3) ◽  
pp. 264-289 ◽  
Author(s):  
Michał Piasecki ◽  
Krystyna Kostyrko ◽  
Sławomir Pykacz

Indoor environment quality is a relative measure of comfort perception by people exposed to the indoor conditions. It is expected that any assessment of energy performance should also include indoor comfort. This study is to review indoor environmental quality models (with respect to thermal and acoustic comfort, indoor air and lighting quality). A simplified indoor environmental quality model is also developed with consideration of EN 15251 draft ‘Guideline for using indoor environmental input parameters for the design and assessment of energy performance of buildings’. This article analyses what components should be modelled and in particular discusses the effect of different weighting schemes on the overall indoor environmental quality index. The analysis includes thermal comfort models, indoor air quality, acoustic comfort and daylight illumination versus lightning. The proposed indoor environmental quality component sub-models will give the most reliable results when the model indoor environment input data are correctly measured and disturbing influences of indoor environmental quality monitoring process are well defined and properly assessed. The final indoor environmental quality result is based on subjoining the uncertainty values achieved in panel analysis of percentage of persons dissatisfied with indoor environmental quality with corrected measurement uncertainty. All simulations for IEQindex sub-components and preliminary metrological analysis of the whole indoor environmental quality model were performed with the NIST program for Monte Carlo tests. The presented indoor environmental quality model proposal is developed to support engineers’ practice as the convenient tool for a practical assessment of building’s occupational satisfaction.


2020 ◽  
Vol 12 (2) ◽  
pp. 643 ◽  
Author(s):  
Claudia Valderrama-Ulloa ◽  
Lorena Silva-Castillo ◽  
Catalina Sandoval-Grandi ◽  
Carlos Robles-Calderon ◽  
Fabien Rouault

The amount of time people spend inside buildings is significant. Indoor environment quality deficiencies in some of these buildings may affect the health of its users. Therefore, a systematic literature review has been conducted to assess the quality of indoor environments in existing buildings in Latin America. The objectives of this review are (1) identifying countries and building types whose indoor environment quality has been analyzed the most, (2) identifying most used evaluation strategies, (3) identifying comfort types and most evaluated variables, and (4) determining whether or not Latin American buildings are comfortable and what local factors contribute to that effect. From the 100 selected papers for this analysis, it was noted that Brazil and Argentina led the studies on residences and schools. It was also noted that hygrothermal comfort was the most analyzed comfort type, with temperature and humidity leading the number of studies. Finally, this review shows a lack of studies including buildings whose users are sensitive to indoor environmental quality, such as nurseries, senior homes, or health facilities. Additionally, there is a sustained discrepancy between objective measuring methods and user perception. Furthermore, a detailed analysis of 88 buildings shows that in Latin America, 67.5% of buildings are uncomfortable; thus, it is necessary to improve the designs and regulatory standards, to educate users, and to improve building monitoring management at the operational stage.


Sign in / Sign up

Export Citation Format

Share Document