scholarly journals Coating Dental Implants with Synthetic Bone Mineral for Early New Bone Formation in Vivo

2021 ◽  
Vol 30 (4) ◽  
pp. 339-346
Author(s):  
Hiroshi Nakada ◽  
Takehiro Watanabe ◽  
Takahiro Takahashi ◽  
Hiroki Sato ◽  
Daisuke Isaji ◽  
...  
Author(s):  
Sergio Alexandre Gehrke ◽  
Margherita Tumedei ◽  
Jaime Aramburú Júnior ◽  
Tiago Luis Eirles Treichel ◽  
Roni Kolerman ◽  
...  

Decompression or healing chambers between the threads have been proposed to improve and accelerate the osseointegration process of dental implants. The aim of the present work was to test, in an in vivo sheep study, if healing chambers between the threads could produce a better osseointegration process. Thirty titanium implants (15 conventional design (control) and 15 implants with healing chambers (test)) were inserted in a random fashion in the tibia of 3 sheep. The animals were euthanized after 30 days of healing, and the retrieved specimens treated to obtain thin ground sections. Histological observations showed that the quantity of newly formed bone growing in an apical direction was lower in the control group (1095 µm) when compared to the Test group (1658 µm). This difference was statistically significant. Moreover, a layer of osteogenic matrix was present around the portion of implants immersed in the marrow spaces. This osteogenic tissue was thicker in the test group. In conclusion, the present study confirmed the very good results in implants with healing chambers that presented a higher percentage of new bone formation.


Materials ◽  
2021 ◽  
Vol 14 (2) ◽  
pp. 381
Author(s):  
Hyunmin Choi ◽  
Kyu-Hyung Park ◽  
Narae Jung ◽  
June-Sung Shim ◽  
Hong-Seok Moon ◽  
...  

The aim of this study was to investigate the behavior of dental-derived human mesenchymal stem cells (d-hMSCs) in response to differently surface-treated implants and to evaluate the effect of d-hMSCs on local osteogenesis around an implant in vivo. d-hMSCs derived from alveolar bone were established and cultured on machined, sandblasted and acid-etched (SLA)-treated titanium discs with and without osteogenic induction medium. Their morphological and osteogenic potential was assessed by scanning electron microscopy (SEM) and real-time polymerase chain reaction (RT-PCR) via mixing of 5 × 106 of d-hMSCs with 1 mL of Metrigel and 20 μL of gel-cell mixture, which was dispensed into the defect followed by the placement of customized mini-implants (machined, SLA-treated implants) in New Zealand white rabbits. Following healing periods of 2 weeks and 12 weeks, the obtained samples in each group were analyzed radiographically, histomorphometrically and immunohistochemically. The quantitative change in osteogenic differentiation of d-hMSCs was identified according to the type of surface treatment. Radiographic analysis revealed that an increase in new bone formation was statistically significant in the d-hMSCs group. Histomorphometric analysis was in accordance with radiographic analysis, showing the significantly increased new bone formation in the d-hMSCs group regardless of time of sacrifice. Human nuclei A was identified near the area where d-hMSCs were implanted but the level of expression was found to be decreased as time passed. Within the limitations of the present study, in this animal model, the transplantation of d-hMSCs enhanced the new bone formation around an implant and the survival and function of the stem cells was experimentally proven up to 12 weeks post-sacrifice.


2020 ◽  
Vol 18 ◽  
pp. 228080002097517
Author(s):  
Yuan-ming Geng ◽  
Dong-ni Ren ◽  
Shu-yi Li ◽  
Zong-yi Li ◽  
Xiao-qing Shen ◽  
...  

Background: Poly Ether Ether Ketone (PEEK) has been considered as a potential alternative material for endosseous dental implants, for its low elastic modulus, biocompatibility, and low cost in customized device manufacture. Hydroxyapatite-incorporation is supposed to improve the poor osseointegration of PEEK. Methods: In the present study we analyzed the in vivo response of hydroxyapatite-incorporated PEEK (PEEK-HA) implants in canine tibia. PEEK-HA and PEEK implants were implanted and were examined 4 weeks and 12 weeks after implantation with radiology and histology. Commercial titanium dental implants served as controls. Results: The ratio of bone volume to tissue volume of PEEK-HA implants was higher than that of PEEK implants 4 weeks after implantation in the μ-CT analysis. The bone implant contact of PEEK and PEEK-HA implants showed no statistical difference in the histological examination, but newly-formed bone around PEEK-HA implants showed more signs of mineralization than that around PEEK implants. Conclusion: The study suggested that bone formation was improved with hydroxyapatite-incorporation in PEEK. Hydroxyapatite-incorporated PEEK implants may represent a potential material for endosseous dental implant.


2007 ◽  
Vol 539-543 ◽  
pp. 710-715
Author(s):  
Kotaro Kuroda ◽  
Ryoichi Ichino ◽  
Masazumi Okido

Hydroxyapatite (HAp) coatings were formed on cp titanium plates and rods by the thermal substrate method in an aqueous solution that included 0.3 mM Ca(H2PO4)2 and 0.7 mM CaCl2. The coating experiments were conducted at 40-140 oC and pH = 8 for 15 or 30 min. The properties for the coated samples were studied using XRD, EDX, FT-IR, and SEM. All the specimens were covered with HAp, which had different surface morphologies such as net-like, plate-like and needle-like. After cleaning and sterilization, all the coated specimens were subjected to in vivo and vitro testing. In the in vitro testing, the mouse osteoblast-like cells (MC3T3-E1) were cultured on the coated and non-coated specimens for up to 30 days. Moreover, the specimens (φ2 x 5 mm) were implanted in rats femoral for up to 8 weeks, the osseoinductivity on them were evaluated. In in vitro evaluations, there were not significant differences between the different surface morphologies. In in vivo evaluations, however, two weeks postimplantation, new bone formed on both the HAp coated and non-coated titanium rods in the cancellous and cortical bone. The bone-implant contact ratio, which was used for the evaluation of new bone formation, was significantly dependent on the surface morphology of the HAp, and the results demonstrated that the needle-like coating appears to promote rapid bone formation.


1985 ◽  
Vol 20 (1) ◽  
pp. 1
Author(s):  
Sang Cheol Seong ◽  
Young Min Kim ◽  
Han Koo Lee ◽  
In Ho Choi ◽  
Moon Sang Chung ◽  
...  

Author(s):  
Eizaburo Kobayashi ◽  
Masako Fujioka‐Kobayashi ◽  
Nikola Saulacic ◽  
Benoit Schaller ◽  
Anton Sculean ◽  
...  

2020 ◽  
Vol 9 (2) ◽  
pp. 60-70 ◽  
Author(s):  
Zhijun Li ◽  
Masaki Arioka ◽  
Yindong Liu ◽  
Maziar Aghvami ◽  
Serdar Tulu ◽  
...  

Aims Surgeons and most engineers believe that bone compaction improves implant primary stability without causing undue damage to the bone itself. In this study, we developed a murine distal femoral implant model and tested this dogma. Methods Each mouse received two femoral implants, one placed into a site prepared by drilling and the other into the contralateral site prepared by drilling followed by stepwise condensation. Results Condensation significantly increased peri-implant bone density but it also produced higher strains at the interface between the bone and implant, which led to significantly more bone microdamage. Despite increased peri-implant bone density, condensation did not improve implant primary stability as measured by an in vivo lateral stability test. Ultimately, the condensed bone underwent resorption, which delayed the onset of new bone formation around the implant. Conclusion Collectively, these multiscale analyses demonstrate that condensation does not positively contribute to implant stability or to new peri-implant bone formation. Cite this article: Bone Joint Res. 2020;9(2):60–70.


2010 ◽  
Vol 654-656 ◽  
pp. 2065-2070
Author(s):  
Ho Yeon Song ◽  
Young Hee Kim ◽  
Jyoti M. Anirban ◽  
In Seon Byun ◽  
Kyung A Kwak ◽  
...  

Calcium phosphate ceramics such as hydroxy apatite (HA), β-tricalcium phosphate (β-TCP) and bicalcium phosphate (BCP) have been used as a bone graft biomaterial because of their good biocompatibility and similarity of chemical composition to natural bones. To increase the mechanical and osteoconductive properties, the granules and spongy type porous bone graft substitutes were prepared by fibrous monolithic process and polyurethane foam replica methods, respectively. The pore sizes obtained using these approaches ranged between 100-600 µm. The cytotoxicity, cellular proliferation, differentiation and ECM deposition on the bone graft substitutes were observed by SEM and confocal microscopy. Moreover, the scaffolds were implanted in the rabbit femur. New bone formation and biodegradation of bone graft were observed through follow-up X-ray, micro-CT analysis and histological findings. After several months (2, 3, 6, 12 and 24 months) of implantation, new bone formation and ingrowths were observed in defect sites of the animal by CaP ceramics and 2 to 3 times higher bone ingrowths were confirmed than that of the normal trabecular bones in terms of total bone volume (BV).


Sign in / Sign up

Export Citation Format

Share Document