scholarly journals A Validated specific Stability-Indicating Reversed-Phase High-Performance Liquid Chromatography Assay Method for L-Ornithine L-Aspartate and Silymarin, and their related Substances and its Application to Dissolution Studies

2020 ◽  
Vol 11 (03) ◽  
pp. 317-328
Author(s):  
Prasada Rao Kammela ◽  
Bhavani Podili ◽  
Mohan Seelam

The present study was aimed at the development and successive validation of a novel, simple, sensitive, and stability-indicating reversed-phase high-performance liquid chromatography (RP-HPLC) method for quantitative calculation of L-ornithine L-aspartate (LOLA) and Silymarin (SL), and also their relevant substances in bulk and pharmaceutical dosage forms. The chromatographic technic was optimized using the impurity-spiked solution. The separation of all the two active components and their impurities was achieved by a chromatographic method with an Agilent Eclipse XDB-C18, 150 × 4.6 mm, 3.5 μ column, using gradient elution with mobile phase A consisting of a mixture of 0.1% orthophosphoric acid and water and acetonitrile as mobile phase B. The instrumental settings included a flow rate of 1 mL/min for both related substances and assay, a detector wavelength of 225 nm, by using a PDA detector. The established method was validated according to the current ICH requirements. The detection limit and the limit of quantification for the two active components and their related impurities were established with respect to test concentration. The calibration graphs plotted were linear with a regression coefficient R2 andgt; 0.999, indicates the linearity of the method was within the limits. Recovery studies were satisfactory and the parameters, such as, specificity, linearity, accuracy, precision, and robustness were determined as part of the method validation. Moreover, using the same method dissolution study was performed on active pharma ingredients to estimate the recovery. The obtained results were within the range of acceptance criteria. These results suggest that the developed method was found to be applicable for routine analysis for testing chromatographic purity of LOLA and SL and it can be utilized for the calculation of both active ingredients and their impurities in tablet dosage forms.

Author(s):  
Mannem Durga Babu ◽  
Kesana Surendrababu

Objective: The objective of the study was to develop and validate a novel, specific, precise, and simple reversed-phase high-performance liquid chromatography method for the estimation of guaifenesin present in methocarbamol API and its pharmaceutical dosage forms. Methods: The baseline separation for methocarbamol and guaifenesin was achieved by utilizing a Inertsil ODS C18 (250 mm × 4.6 mm) 5 μm column particle size and an isocratic elution method. The mobile phase contains a mixture of water and acetonitrile in the ratio of 70:30 v/v, respectively. The flow rate of the mobile phase was 1.0 mL/min with a column temperature of 25°C and detection wavelength at 272 nm. The method was validated for a limit of detection (LOD), limit of quantification (LOQ), linearity, accuracy, and reproducibility with the help of the exhibit and simulated samples. Results: The LOD for guaifenesin was 0.62 μg/mL. The LOQ for guaifenesin was 1.87 μg/mL. The correlation coefficient obtained for impurity was >0.99. The recovery was obtained for impurity was 106.56% at 50%, 95.20% at 100%, and 100.45% at 150%. In tablet analysis, we can found 0.26% (<0.5%). Conclusion: The developed method was validated as per the ICH guidelines with respect to specificity, precision, linearity, accuracy, LOD and quantification, ruggedness, robustness, and solution stability.


Author(s):  
B.sai Kumar ◽  
Jyothi G ◽  
Sreenivasa Rao B

<p>ABSTRACT<br />Objective: A simple and accurate stability indicating reversed-phase high-performance liquid chromatography method was developed and validated<br />for the simultaneous estimation of phenylephrine and fexofenadine in pharmaceutical dosage forms.<br />Methods: Chromatography was carried out on an ODS C-18 column (4.6 mm×250 mm, 5 µ particle size) with a isocratic mobile phase composed of<br />orthophosphoric acid buffer, acetonitrile, (75:25% v/v) at a flow rate of 1 mL/minutes. The column temperature was maintained at 30°C and the<br />detection was carried out using a photodiode array detector at 210 nm.<br />Results: The retention times for phenylephrine and fexofenadine were 2.096 minutes and 4.241 minutes, respectively. The percentage recoveries<br />of phenylephrine and fexofenadine were 100.63% and 99.84%, respectively. The relative standard deviation for assay of tablets was found to be<br />&lt;2%. The detection and quantification limits were found to be 0.10 and 0.31 µg/mL for phenylephrine and 0.01 and 0.03 µg/mL for fexofenadine,<br />respectively.<br />Conclusion: Thus, the method was fast, accurate, precise, and sensitive; hence, it can be employed for routine quality control of tablets containing<br />both drugs in quality control laboratories and pharmaceutical industries.<br />Keywords: Phenylephrine, Fexofenadine, Stability indicating method, Validation method, Reversed-phase high performance liquid chromatography.</p>


1994 ◽  
Vol 59 (3) ◽  
pp. 569-574 ◽  
Author(s):  
Josef Královský ◽  
Marta Kalhousová ◽  
Petr Šlosar

The reversed-phase high-performance liquid chromatography of some selected, industrially important aromatic sulfones has been investigated. The chromatographic behaviour of three groups of aromatic sulfones has been studied. The optimum conditions of separation and UV spectra of the sulfones and some of their hydroxy and benzyloxy derivatives are presented. The dependences of capacity factors vs methanol content in mobile phase are mentioned. The results obtained have been applied to the quantitative analysis of different technical-grade samples and isomer mixtures. For all the separation methods mentioned the concentration ranges of linear calibration curves have been determined.


1977 ◽  
Vol 23 (12) ◽  
pp. 2288-2291 ◽  
Author(s):  
P H Culbreth ◽  
I W Duncan ◽  
C A Burtis

Abstract We used paired-ion high-performance liquid chromatography to determine the 4-nitrophenol content of 4-nitrophenyl phosphate, a substrate for alkaline phosphatase analysis. This was done on a reversed-phase column with a mobile phase of methanol/water, 45/55 by vol, containing 3 ml of tetrabutylammonium phosphate reagent per 200 ml of solvent. At a flow rate of 1 ml/min, 4-nitrophenol was eluted at 9 min and monitored at 404 nm; 4-nitrophenyl phosphate was eluted at 5 min and could be monitored at 311 nm. Samples of 4-nitrophenyl phosphate obtained from several sources contained 0.3 to 7.8 mole of 4-nitrophenol per mole of 4-nitrophenyl phosphate.


Author(s):  
Muhammad Fawad Rasool ◽  
Umbreen Fatima Qureshi ◽  
Nazar Muhammad Ranjha ◽  
Imran Imran ◽  
Mouqadus Un Nisa ◽  
...  

AbstractTh accurate rapid, simple and selective reversed phase high performance liquid chromatography (RP-HPLC) has been established and validated for the determination of captopril (CAP). Chromatographic separation was accomplished using prepacked ODSI C18 column (250 mm × 4.6 mm with 5 μm particle size) in isocratic mode, with mobile phase consisting of water: acetonitrile (60:40 v/v), pH adjusted to 2.5 by using 85% orthophosphoric acid at a flow rate of 1 mL/min and UV detection was performed at 203 nm. RP-HPLC method used for the analysis of CAP in mobile phase and rabbit plasma was established and validated as per ICH-guidelines. It was carried out on a well-defined chromatographic peak of CAP was established with a retention time of 4.9 min and tailing factor of 1.871. The liquid–liquid extraction method was used for extraction of CAP from the plasma. Excellent linearity (R2 = 0.999) was shown over range 3.125–100 µg/mL with mean percentage recoveries ranges from 97 to 100.6%. Parameters of precision and accuracy of the developed method meet the established criteria. Intra and inter-day precision (% relative standard deviation) study was also performed which was less than 2% which indicate good reproducibility of the method. The limit of detection (LOD) and quantification for the CAP in plasma were 3.10 and 9.13 ng/mL respectively. The method was suitably validated and successfully applied to the determination of CAP in rabbit plasma samples.


Author(s):  
PULAGURTHA BHASKARARAO ◽  
GOWRI SANKAR DANNANA

Objective: Noscof tablet is a fixed dosage combination formulation having diphenhydramine (DH), ephedrine (ED), noscapine (NP), and glycerol glycolate (GG). A sensitive, selective, accurate, precise, and stability-indicating reversed-phase high-performance liquid chromatography (RP-HPLC) method with photodiode array detection has been developed and validated for simultaneous analysis of DH, ED, NP, and GG in bulk drug and Noscof tablets. Methods: Reversed-phase chromatographic separation and analysis of DH, ED, NP, and GG were done on an Altima C18 column with 0.01 M KH2PO4 buffer (pH 3.5) and acetonitrile (50:50%, v/v) as mobile phase at 0.8 ml/min flow rate in isocratic mode. Detection was performed at 260 nm. The method was validated in harmony with International Conference on Harmonization (ICH) guidelines. The tablet sample solution was subjected to diverse stress conditions using ICH strategy such as hydrolytic degradation (neutral - with distilled water, alkaline - with 2 N NaOH, and acidic - with 2 N HCl), oxidation (with 10% H2O2), photodegradation (exposing to UV light), and dry heat degradation (exposing to 105°C). Results: Using the above stated chromatographic conditions, sharp peaks were obtained for ED, NP, DH, and GG with retention time of 3.272 min, 4.098 min, 5.467 min, and 6.783 min, respectively. Good regression coefficient values were obtained in the range of 2–12 μg/ml for ED, 3.75–22.5 μg/ml for NP, 3.125–18.75 μg/ml for DH, and 25–150 μg/ml for GG. The quantification limits were 0.181 μg/ml, 0.187 μg/ml, 0.246 μg/ml, and 1.114 μg/ml for ED, NP, DH, and GG, respectively. The values of validation parameters are within the acceptance limits given by ICH. The ED, NP, DH, and GG showed more percent of degradation in acid condition and less percent of degradation in the neutral condition. The peaks of degradants did not interfere with the peaks of analytes. ED, NP, DH, and GG were assessed with a good percentage of the assay (near to 100%) and low percent relative standard deviation (<2%) in Noscof tablets using the proposed method. Conclusion: The stability indicating RP-HPLC method developed was suitable for quantifying ED, NP, DH, and GG simultaneously in bulk as well as in tablet formulation.