scholarly journals High Response Bio-Analytical Validation approach of Nadolol and Bendroϑlumethiazide by LC-MS/MS on Rat plasma

2020 ◽  
Vol 11 (SPL4) ◽  
pp. 2272-2279
Author(s):  
Naveen V M K ◽  
Veeraswami B ◽  
Srinivasa Rao G

A very strong responsive and straight forward the LC-MS / MS assay was developed to and witnessed for that gradation in Nadolol and Bendroflumethiazide in rat plasma. The chromatographic conditions involve isocratic mode using Waters symmetry C18 (150x4.6 mm, 3.5 microns) column. A 0.1 per cent Smartphone process OPA (orthophosphoric Acid) Acetonitrile and in 60:40 is employed, and therefore the detection was administered during +ve mode of electrospray ionisation by using MS. The valid method had validated in the linear range of 8-160 ng/ml Nadolol and 1-20 ng/ml bendroflumethiazide, the precise values considered to be intraday and interday within the acceptable limit. Here these drugs are extracted from the rat plasma by using the liquid-liquid extraction. And these drugs are found stable. Through freeze Thaw, sampler app, vehicle sampler and top of the bench for the future studies. Form of liquid chromatography-tandem mass spectrometry and checked in compliance with guidelines for quantification of food and drug administration Nadolol and Bendroflumethiazide plasma in rats using D6-Nadolol and D6-Bendroflumethiazide as internal standards utilising LC-MS incorporated with quadrupole spectrometer by using electrospray ionisation technique. The target of this analysis is to be done work out the appropriateness of this approach to Nadolol and Bendroflumethiazide Applying Nadolol and bendroflumethiazide and their internal requirements at various quantification stages and retaining different parameters such as instrument durability, precision and accuracy, sample preparation techniques, instrument synchronisation, recovery and matrix effect.

Author(s):  
David M Andrenyak ◽  
David E Moody ◽  
Jonathan M Crites ◽  
Michael H Baumann

Abstract Alpha-pyrrolidinovalerophenone (alpha-PVP), a novel psychoactive substance, has widespread recreational use. This with interest in its pharmacological effects creates a need for methods that measure alpha-PVP concentrations. We therefore developed a LC-MS/MS method that can quantitate alpha-PVP and 2-oxo-PVP in rat plasma using a 0.1-mL sample volume. Addition of internal standards (2.5 ng/mL alpha-PVP-d8/2-oxo-PVP-d6) was followed by liquid–liquid extraction with 1-chlorobutane:acetonitrile (4:1), evaporation and reconstitution with 0.1% formic acid. Extracts were analyzed by LC-MS/MS using an Agilent 1100 HPLC and a Thermo Scientific TSQ Quantum Access MS/MS, with a YMC ODS-AQ, 50 mm × 2 mm, 3 μm column. The mobile phase was 0.1% formic acid:acetonitrile gradient at a 0.2-mL/minute flow rate with positive ion electrospray. SRM was used for the analysis with transitions: alpha-PVP, 232 → 91; alpha-PVP-d8, 240 → 91; 2-oxo-PVP, 246 → 91; 2-oxo-PVP-d6, 252 → 91. Alpha-PVP and 2-oxo-PVP eluted at 6.4 and 8.9 min. Calibrators range from 0.25 to 500 ng/mL. Accuracy and precision evaluated quality control samples prepared at 0.75, 10 and 400 ng/mL. The intra-assay evaluation also included the 0.25-ng/mL LOQs prepared in six different blank plasma sources. The intra-assay accuracy ranged from 88.9 to 117.8% of the target, and the intra-assay precision ranged from 0.9 to 16.0%. The inter-assay accuracy ranged from 98.7 to 110.7% of the target, and the inter-assay precision ranged from 4.5 to 12.0%. Extraction recovery was at least 52% for alpha-PVP and 67% for 2-oxo-PVP. Ionization recoveries were at least 64% for alpha-PVP and 82% for 2-oxo-PVP. These losses did not adversely affect assay performance. Alpha-PVP and 2-oxo-PVP controls were stable at room temperature for up to 24 h and frozen for at least 36 days. Alpha-PVP and 2-oxo-PVP were also stable in processed samples (extracts) stored at room temperature for at least 24 days. The procedure was used to analyze rat plasma samples from a pharmacokinetic study.


Molecules ◽  
2021 ◽  
Vol 26 (14) ◽  
pp. 4357
Author(s):  
Waritda Pookmanee ◽  
Siriwan Thongthip ◽  
Jeeranut Tankanitlert ◽  
Mathirut Mungthin ◽  
Chonlaphat Sukasem ◽  
...  

The method for the determination of primaquine (PQ) and 5,6-orthoquinone primaquine (5,6-PQ), the representative marker for PQ active metabolites, via CYP2D6 in human plasma and urine has been validated. All samples were extracted using acetonitrile for protein precipitation and analyzed using the ultra-high-performance liquid chromatography–tandem mass spectrometry (UHPLC-MS/MS) system. Chromatography separation was carried out using a Hypersil GOLDTM aQ C18 column (100 × 2.1 mm, particle size 1.9 μm) with a C18 guard column (4 × 3 mm) flowed with an isocratic mode of methanol, water, and acetonitrile in an optimal ratio at 0.4 mL/min. The retention times of 5,6-PQ and PQ in plasma and urine were 0.8 and 1.6 min, respectively. The method was validated according to the guideline. The linearity of the analytes was in the range of 25–1500 ng/mL. The matrix effect of PQ and 5,6-PQ ranged from 100% to 116% and from 87% to 104% for plasma, and from 87% to 89% and from 86% to 87% for urine, respectively. The recovery of PQ and 5,6-PQ ranged from 78% to 95% and form 80% to 98% for plasma, and from 102% to from 112% to 97% to 109% for urine, respectively. The accuracy and precision of PQ and 5,6-PQ in plasma and urine were within the acceptance criteria. The samples should be kept in the freezer (−80 °C) and analyzed within 7 days due to the metabolite stability. This validated UHPLC-MS/MS method was beneficial for a pharmacokinetic study in subjects receiving PQ.


Author(s):  
Rebecca A Mastrovito ◽  
Donna M Papsun ◽  
Barry K Logan

Abstract Novel illicit benzodiazepines are among the most active areas of new illicit drug manufacture and use. We describe a method for the detection and quantification of etizolam and its metabolite α-hydroxyetizolam, flubromazolam, clonazolam, diclazepam, delorazepam, bromazepam, flubromazepam, phenazepam, flualprazolam, flunitrazolam, and nitrazolam in human whole blood. After addition of internal standards, samples are buffered and extracted using a liquid–liquid extraction. Analysis is performed using positive-ion electrospray tandem mass spectrometry for detection and quantitation. Calibration ranges were established based on the method performance and differed from compound to compound. Replicates at the lowest calibration point for each compound performed within 5% of CV (Coefficient of Variation). The correlation coefficient was >0.990 for all compounds. Relative standard deviation for all compounds was ≤10% of CV and accuracy was  ±10% for both within- and between-run experiments. The maximum average intra- and inter-run imprecision were 5.7%. The maximum average intra- and inter-run imprecision was −8.7%. As part of evaluating the scope for relevancy, samples testing positive in immunoassay but confirmed to be negative in traditional benzodiazepine confirmation method were re-analyzed using this method. The presence of at least one novel benzodiazepine was identified in 70% of these samples. The appearance of these novel “designer” benzodiazepines demonstrates the challenge for toxicology testing and the need for continually updated confirmation methods.


Author(s):  
Ana Carolina Furiozo Arantes ◽  
Kelly Francisco da Cunha ◽  
Marilia Santoro Cardoso ◽  
Karina Diniz Oliveira ◽  
Jose Luiz Costa

Abstract Purpose We developed and validated a method for quantitative analysis of 50 psychoactive substances and metabolites (antidepressants, benzodiazepines and opioids) in oral fluid samples using simple liquid–liquid extraction procedure followed by liquid chromatography–tandem mass spectrometry (LC–MS/MS). Method Oral fluid samples were collected using Quantisal™ device and extracted by liquid–liquid extraction with 1.0 mL of methyl tert-butyl ether and then analyzed using LC–MS/MS. Results The method attended method validation criteria, with limits of quantification as low as 0.5 and 1.0 ng/mL, and linearity between 0.5–50.0 ng/mL for antidepressants, 0.5–25.0 ng/mL for benzodiazepines and 1.0–50.0 ng/mL to opioids. During method validation, bias and imprecision values were not greater than 16 and 20%, respectively. Ionization suppression/enhancement bias results were not greater than 25%. No evidence of carryover was observed. Sample stability studies showed that almost all analytes were stable at 25 °C for 3 days and at 4 °C for 7 days. Freeze–thaw cycles stability showed that most antidepressants and opioids were stable under these conditions. Autosampler stability study showed that all analytes were stable for 24 h, except for nitrazepam and 7-aminoclonazepam. Thirty-eight authentic oral fluid samples were analyzed; 36.8% of the samples were positive for 2 drugs. Citalopram was the most common drug found, followed by venlafaxine. Conclusions The method was validated according to international recommendations for the 50 analytes, showing low limits of quantification, good imprecision and bias values, using simple liquid–liquid extraction, and was successfully applied to authentic oral fluid samples analysis.


Author(s):  
Maria Rincon Nigro ◽  
Jing Ma ◽  
Ololade Tosin Awosemo ◽  
Huan Xie ◽  
Omonike Arike Olaleye ◽  
...  

OJT007 is a methionine aminopeptidase 1 (MetAP1) inhibitor with potent anti-proliferative effects against Leishmania Major. In order to study its pharmacokinetics as a part of the drug development process, a sensitive, specific, and reproducible ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated. Voriconazole was used as the internal standard to generate standard curves ranging from 5 to 1000 ng/mL. The separation was achieved using a UPLC system equipped with an Acquity UPLC BEH C18 column (2.1 × 50 mm, 1.7 μm) with 0.1% formic acid in acetonitrile and 0.1% formic acid in water as the mobile phase under gradient elution at a flow rate of 0.4 mL/min. The mass analysis was performed with a 4000 QTRAP® mass spectrometer using multiple-ion reaction monitoring (MRM) in the positive mode, with the transition of m/z 325 → m/z 205 for OJT007 and m/z 350 → m/z 101 for voriconazole. The intra- and inter-day precision and accuracy were within ±15%. The mean extraction recovery and the matrix effect were 95.1% and 7.96%, respectively, suggesting no significant matrix interfering with the quantification of the drug in rat plasma. This study was successfully used for the pharmacokinetic evaluation of OJT007 using the rat as an animal model.


Sign in / Sign up

Export Citation Format

Share Document