scholarly journals SIMULATION OF A WATER CURTAIN APPLICATION TO PROTECT WORKERS FROM THERMAL INJURIES

Author(s):  
M. BILIAIEV ◽  
O. BERLOV ◽  
V. BILIAIEVA ◽  
O. VERGUN

Problem statement. The problem of evaluating the effectiveness of using the water curtain to reduce the risk of thermal injury to people in a fire is considered. The problem is to determine the temperature fields when supplying water for air cooling. The purpose of the article. Development of a numerical model for calculating the process of propagation of water droplets in the air, their evaporation to reduce the temperature of heated air due to fire. Methodology. For mathematical modeling of the process of propagation of water droplets in air, thermal air pollution, the convective-diffusion equation of mass transfer, the energy equation and the equation describing the motion of an ideal liquid (potential flow model) are used. The potential flow model allows you to quickly determine the field of air flow velocity in areas with a complex geometric shape. Implicit difference splitting schemes are used for numerical integration of the convective-diffusion mass transfer equation and the energy equation. Physical splitting of basic equations is used to construct a difference analogue of modeling equations. The Richardson method and the conditional approximation scheme are used to solve the aerodynamics problem of determining the velocity potential field and the components of the air velocity vector. An engineering method for calculating the process of evaporation of a drop of water based on Sreznevsky's law has been developed. Scientific novelty. An effective numerical model has been developed that allows the method of computational experiment to determine the efficiency of using the water curtain to reduce the level of thermal pollution of atmospheric air due to fire. The numerical model is based on the integration of the fundamental equations of aerodynamics, heat and mass transfer. The model takes into account the most significant physical factors that affect the process under study: the movement of heated air, the movement of water droplets in the air, evaporation of the droplet, and so on. Practical significance. Based on the built model, a computer code has been created that allows you to quickly determine the temperature fields in the air when using a water curtain. The numerical model will be useful when conducting computational experiments for the purpose of scientifically sound choice of the location of the water curtain in case of fire. Conclusions. A computer code has been created that allows a computational experiment to investigate the effectiveness of using a water curtain in a fire. The developed computer program can be implemented on low and medium power computers. The results of a computational experiment are presented.

2019 ◽  
Vol 13 (4) ◽  
pp. 112-117 ◽  
Author(s):  
V.Sh. Shagapov ◽  
M.N. Zapivakhina

The numerical models for the injection of warm water (in the temperature range from 300 to 340 K) into a cold porous formation are considered. Simplified models describing the processes of heat and mass transfer are proposed. The influence of the parameters determining the initial state of the porous medium, the boundary pressure, temperature and moisture content on the rate of propagation of hydrodynamic and temperature fields in the porous medium is investigated. It has been established that it is economically feasible to melt frozen soils saturated with ice and gas (air) at a sufficiently low temperature of the injected water (about 300 K).


Proceedings ◽  
2020 ◽  
Vol 58 (1) ◽  
pp. 31
Author(s):  
Jeremy Arancio ◽  
Ahmed Ould El Moctar ◽  
Minh Nguyen Tuan ◽  
Faradj Tayat ◽  
Jean-Philippe Roques

In the race for energy production, supplier companies are concerned by the thermal rating of offshore cables installed in a J-tube, not covered by IEC 60287 standards, and are now looking for solutions to optimize this type of system. This paper presents a numerical model capable of calculating temperature fields of a power transmission cable installed in a J-tube, based on the lumped element method. This model is validated against the existing literature. A sensitivity analysis performed using Sobol indices is then presented in order to understand the impact of the different parameters involved in the heating of the cable. This analysis provides an understanding of the thermal phenomena in the J-tube and paves the way for potential technical and economic solutions to increase the ampacity of offshore cables installed in a J-tube.


Author(s):  
Виктор Григорьевич Чеверев ◽  
Евгений Викторович Сафронов ◽  
Алексей Александрович Коротков ◽  
Александр Сергеевич Чернятин

Существуют два основных подхода решения задачи тепломассопереноса при численном моделировании промерзания грунтов: 1) решение методом конечных разностей с учетом граничных условий (границей, например, является фронт промерзания); 2) решение методом конечных элементов без учета границ модели. Оба подхода имеют существенные недостатки, что оставляет проблему решения задачи для численной модели промерзания грунтов острой и актуальной. В данной работе представлена физическая постановка промерзания, которая позволяет создать численную модель, базирующуюся на решении методом конечных элементов, но при этом отражающую ход фронта промерзания - то есть модель, в которой объединены оба подхода к решению задачи промерзания грунтов. Для подтверждения корректности модели был проделан ряд экспериментов по физическому моделированию промерзания модельного грунта и выполнен сравнительный анализ полученных экспериментальных данных и результатов расчетов на базе представленной численной модели с такими же граничными условиями, как в экспериментах. There are two basic approaches to solving the problem of heat and mass transfer in the numerical modeling of soil freezing: 1) using the finite difference method taking into account boundary conditions (the boundary, for example, is the freezing front); 2) using the finite element method without consideration of model boundaries. Both approaches have significant drawbacks, which leaves the issue of solving the problem for the numerical model of soil freezing acute and up-to-date. This article provides the physical setting of freezing that allows us to create a numerical model based on the solution by the finite element method, but at the same time reflecting the route of the freezing front, i.e. the model that combines both approaches to solving the problem of soil freezing. In order to confirm the correctness of the model, a number of experiments on physical modeling of model soil freezing have been performed, and a comparative analysis of the experimental data obtained and the calculation results based on the provided numerical model with the same boundary conditions as in the experiments was performed.


2011 ◽  
Vol 19 (02) ◽  
pp. 121-129 ◽  
Author(s):  
PASUPATHY BALAMURUGAN ◽  
ANNAMALAI MANI

A model has been developed based on Colburn–Drew type formulation to analyze a vertical tube in tube stainless steel generator with forced convective boiling. Desorption of refrigerant vapor from refrigerant–absorbent solution takes place in the inner tube of the generator, when hot water through the annulus is used as heating medium. Simultaneous heat and mass transfer phenomena of desorption are described mathematically using the mass and energy balances, considering the heat and mass transfer resistances in liquid as well as vapor phases. Model equations are solved simultaneously by means of initial value problem solvers using explicit Runge–Kutta method with 4th order accuracy. A computer code has been developed in MATLAB to obtain the results. A parametric analysis has also been performed to study the effect of various parameters on the performance of the generator.


2019 ◽  
Vol 85 ◽  
pp. 02017 ◽  
Author(s):  
Andrei-Stelian Bejan ◽  
Florin Bode ◽  
Tiberiu Catalina ◽  
Cătalin Teodosiu

In order to achieve the numerical model of a transpired solar collector (TSC) with integrated phase changing materials (PCM) it is mandatory to study the impact of the orifice geometry on the entire system. The numerical simulation of the entire solar collector absorber metal plate (1000x2000mm and 5000 orifices) is not feasible thus resulting a huge number of cells for the numerical grid for which we will need very high computational resources and a very large amount of time to be solved. By taking these aspects into account we decided to simulate only four equivalent orifices and then to transpose the results to the actual case for further studies. The present paper aims to analyse the mesh independency study for an elementary perforated panel with four equivalent lobed orifices which is part of a real case TSC. This analysis represents one of the most important stages within the construction of the TSC numerical model and doesn't need an experimental validation. The study was conducted in Ansys Fluent CFD software and the results were processed directly by using Tecplot software. Six different meshes were analysed (from 0.2 to 7.3 million cells), boundary conditions were imposed, and k-ε RNG turbulence model was used according to the literature. After comparing velocity and temperature fields in longitudinal and transverse planes we concluded that from 5.3 million cells the solution is independent of the meshing quality.


2019 ◽  
Vol 9 (4) ◽  
pp. 753 ◽  
Author(s):  
Shanju Yang ◽  
Zhan Liu ◽  
Bao Fu ◽  
Yu Chen

Frost formation degrades the performance of heat exchangers greatly, thus influencing the cryogenic refrigerator. Different from frost formation on the evaporator surface, the growth and migration of frost layer inside the heat exchanger is of low temperature and humidity. In addition to the constantly changing boundary conditions, the effective prediction is difficult. In the present study, a numerical model was proposed to analyze the frost formation in the cryogenic heat exchanger of a reverse Brayton air refrigerator. Under small amounts of moisture, the growing of frost layer was simulated through the numerical heat and mass transfer by adopting semiempirical correlations. The frost formation model was inserted into the transient model of refrigerator, and numerical calculations were performed on heat and mass transfer rates, and growth and migration of frost layers in forced convection conditions. Experiments were conducted under different air humidity to investigate the frost formation and verify the numerical model. Through the model, the influences of frosting on the refrigerator were evaluated under different moisture contents and running time. It can be used to predict the performance of air refrigerators with low humidity and provide a basis for improving the system operation and efficiency.


2014 ◽  
Vol 6 ◽  
pp. 865856 ◽  
Author(s):  
Roman S. Volkov ◽  
Olga V. Vysokomornaya ◽  
Genii V. Kuznetsov ◽  
Pavel A. Strizhak

The macroscopic regularities of heat and mass transfer and phase transitions during water droplets motion through high-temperature (more than 1000 K) gases have been investigated numerically and experimentally. Water droplet evaporation rates have been established. Gas and water vapors concentrations and also temperature values of gas-vapor mixture in small neighborhood and water droplet trace have been singled out. Possible mechanisms of droplet coagulation in high-temperature gas area have been determined. Experiments have been carried out with the optical methods of two-phase gas-vapor-droplet mixtures diagnostics (“Particle Image Velocimetry” and “Interferometric Particle Imaging”) usage to assess the adequateness of developed heat and mass transfer models and the results of numerical investigations. The good agreement of numerical and experimental investigation results due to integral characteristics of water droplet evaporation has been received.


2006 ◽  
Vol 16 (10) ◽  
pp. 1559-1598 ◽  
Author(s):  
ALFREDO BERMÚDEZ ◽  
RODOLFO RODRÍGUEZ ◽  
DUARTE SANTAMARINA

This paper deals with a time-domain mathematical model for dissipative acoustics and is organized as follows. First, the equations of this model are written in terms of displacement and temperature fields and an energy equation is obtained. The resulting initial-boundary value problem is written in a functional framework allowing us to prove the existence and uniqueness of solution. Next, two different time-discretization schemes are proposed, and stability and error estimates are proved for both. Finally, numerical results are reported which were obtained by combining these time-schemes with Lagrangian and Raviart–Thomas finite elements for temperature and displacement fields, respectively.


Sign in / Sign up

Export Citation Format

Share Document