scholarly journals Determination of active ingredients in commercial insecticides using spectral characteristics of Fourier transform infrared spectroscopy (FTIR)

2021 ◽  
Vol 13 (SI) ◽  
pp. 110-123
Author(s):  
B. Asan Mohamed ◽  
P. Janaki

Pesticides have become a basic necessity for yield development. This might be credited to the quickly expanding population, which has presented weight on the food creation industry.Fourier Transform Infra-red Spectroscopy utilizes sample with less course of action, less time consuming, simple, fast, non-destructive and environmental friendly infrared-based method. It makes use of Smart iTR window and pellets use on omnic transmission window. In FTIR the peaks formed for the representative sample are from 800 cm-1 to 4000 cm-1 of wavenumbers against the % transmittance. The FTIR spectra obtained for pesticide formulations were on par with the NIST (National Institute of Standards and Technology) spectra library. Comparing the commercial-grade spectra with the Spectrabase, NIST library and Bio-rad software showed the peak ranges for different functional groups of the compound and can be examined with KnowItAll software’s ProcessItIR and AnalyseItIR. We can obtain the active principle of the peak, peak intensities. This method can be viewed as genuine choices to long and tedious chromatographic strategies as a rule suggested for quality control of commercially accessible pesticide formulations and check for adultered formulations that harm agricultural produce.  

1983 ◽  
Vol 27 ◽  
Author(s):  
L. Salamanca-Riba ◽  
B.S. Elman ◽  
M.S. Dresselhaus ◽  
T. Venkatesan

ABSTRACTRutherford backscattering spectrometry (RBS) is used to characterize the stoichiometry of graphite intercalation compounds (GIC). Specific application is made to several stages of different donor and acceptor compounds and to commensurate and incommensurate intercalants. A deviation from the theoretical stoichiometry is measured for most of the compounds using this non-destructive method. Within experimental error, the RBS results agree with those obtained from analysis of the (00ℓ) x-ray diffractograms and weight uptake measurements on the same samples.


Author(s):  
Prong Kongsubto ◽  
Sirarat Kongwudthiti

Abstract Organic solderability preservatives (OSPs) pad is one of the pad finishing technologies where Cu pad is coated with a thin film of an organic material to protect Cu from oxidation during storage and many processes in IC manufacturing. Thickness of OSP film is a critical factor that we have to consider and control in order to achieve desirable joint strength. Until now, no non-destructive technique has been proposed to measure OSP thickness on substrate. This paper reports about the development of EDS technique for estimating OSP thickness, starting with determination of the EDS parameter followed by establishing the correlation between C/Cu ratio and OSP thickness and, finally, evaluating the accuracy of the EDS technique for OSP thickness measurement. EDS quantitative analysis was proved that it can be utilized for OSP thickness estimation.


Metals ◽  
2020 ◽  
Vol 11 (1) ◽  
pp. 18
Author(s):  
Rahel Jedamski ◽  
Jérémy Epp

Non-destructive determination of workpiece properties after heat treatment is of great interest in the context of quality control in production but also for prevention of damage in subsequent grinding process. Micromagnetic methods offer good possibilities, but must first be calibrated with reference analyses on known states. This work compares the accuracy and reliability of different calibration methods for non-destructive evaluation of carburizing depth and surface hardness of carburized steel. Linear regression analysis is used in comparison with new methods based on artificial neural networks. The comparison shows a slight advantage of neural network method and potential for further optimization of both approaches. The quality of the results can be influenced, among others, by the number of teaching steps for the neural network, whereas more teaching steps does not always lead to an improvement of accuracy for conditions not included in the initial calibration.


Sign in / Sign up

Export Citation Format

Share Document