scholarly journals AN EXTRAPOLATION METHOD OF THE STEEL TEMPERATURE RISE IN FIRE RESISTANCE TEST

2001 ◽  
Vol 66 (541) ◽  
pp. 205-210
Author(s):  
Takahiro ISHIHARA ◽  
Kazunori HARADA ◽  
Syuitsu YUSA ◽  
Takao WAKAMATSU
2020 ◽  
Vol 8 (7) ◽  
pp. 520 ◽  
Author(s):  
Giada Kyaw Oo D’Amore ◽  
Alberto Marinò ◽  
Jan Kašpar

Finite element analysis (FEA) is employed to simulate the thermo-resistance of a marine fire-proof door in the fire-resistance test defined by the International Code for the Application of Fire Test Procedures (2010 FTP Code) and required by the International Maritime Organization (IMO) for marine applications. The appropriate type of simulation adopted (i.e., steady or unsteady) is discriminated on the basis of a comparison between the numerical results and the experimental data. This appropriate model is used to evaluate the critical parameters affecting fire-proof door performance. A remarkable role of the thermal bridge at the door edges in fire resistance is assessed, along with the parameters that allow its reduction. These findings provide insight into how to design a thinner and lighter fire door.


2014 ◽  
Vol 580-583 ◽  
pp. 2646-2648
Author(s):  
Jin Ping Wang

The developed rigid polyurethane foam is added several inorganic materials, which made the polyurethane foam release less poisonous gases in fire. The oxygen index value can reach more than 32 percent, and under the standard heating curve the retardant rigid polyurethane foam can present the performance of 1h fire resistance test.


2000 ◽  
Vol 6 ◽  
pp. 867-878
Author(s):  
T. Ishihara ◽  
Takao Wakamatsu ◽  
Kazunori Harada ◽  
S. Yusa

2021 ◽  
Vol 11 (6) ◽  
pp. 2521
Author(s):  
Feng Jiang ◽  
Jianyong Liu ◽  
Wei Yuan ◽  
Jianbo Yan ◽  
Lin Wang ◽  
...  

Improving the fire resistance of the key cables connected to firefighting and safety equipment is of great importance. Based on the engineering practice of an oil storage company, this study proposes a modification scheme that entails spraying fire-retardant coatings on the outer surface of a cable tray to delay the failure times of the cables in the tray. To verify the effect, 12 specimens were processed using five kinds of fire-retardant coatings and two kinds of fire-resistant cotton to coat the cable tray. The specimens were installed in the vertical fire resistance test furnace. For the ISO 834 standard fire condition, a fire resistance test was carried out on the specimens. The data for the surface temperature and the insulation resistance of the cables in trays were collected, and the fireproof effect was analyzed. The results showed that compared with the control group, the failure time of the cable could be delayed by 1.57–14.86 times, and the thicker the fire-retardant coatings were, the better the fireproof effect was. In general, the fire protection effect of the fire-retardant coating was better than that of the fire-resistant cotton.


Author(s):  
Paweł Roszkowski ◽  
Paweł Sulik

<p>Sandwich panel is the material that is easy and quickly to install. Basing on a great experience in the area of determination of the fire resistance class of construction building elements the authors describe the properties and behavior of building elements made of the sandwich panels exposed to fire. The article presents the results of fire resistance tests carried out in accordance with EN 1364-1 non-bearing walls made of sandwich panels with use of different cores.</p>The following parameters were analyzed: temperature rise on unexposed side (I – thermal insulation), integrity (E) depending on the orientations and on the width of the sandwich panels, deflection depending on the thickness of the boards. Conclusions were made on the base of the analysis from fire resistance tests.


Sign in / Sign up

Export Citation Format

Share Document