scholarly journals Compatibility of Measurement Results using a Rotating Device for Estimating Fetal Weight And The Johnson Toshack Method Newborn Weight

2021 ◽  
Vol 11 (2) ◽  
pp. 91-97
Author(s):  
Sariestya Rismawati ◽  
Etin Rohmatin
Author(s):  
Elnazeer A. Hashim ◽  
Elsir A. Saeed ◽  
Elsadig Y. Mohamed ◽  
Elabbas M. Ebaid ◽  
Hussam Zain ◽  
...  

Background: Ultrasound estimation of fetal weight in term pregnancies is used to determine fetal growth. The objective of this study was to assess the precision of sonographic estimation of fetal weight in normal vaginal deliveries at a rural setting.Methods: The study was cross-sectional. A group of 74 pregnant women delivered normally in Muglad hospital in West Kordofan, Sudan, were considered in the study. Fetal weight was estimated by Hadlock and shephards formulae within one week prior to delivery and then newborn weight was taken within 24 hours after delivery. Data were collected by a questionnaire and medical examination as well as sonographic examination. Data analysis was done by SPSS version 23 and Kruskal Wallis Test (post-hoc analysis) Pearson’s correlation coefficient within 95% confidence interval. p value <0.05 was considered as statistically significant.Results: The correlation, by Paired sample, to assess fetal weight was as follows: between Hadlock and shephards was 0.901 (p < 0.001), between Hadlock and AFW was 0.908 (p < 0.001) and between Shephards and AFW was 0.781 (p < 0.001).Conclusions: Estimation of fetal weight by Hadlock has been more correlated with actual fetal weight (AFW) than that done with shephards. The study recommends using Hadlock formula which is more accurate in estimation of fetal weight by sonography.


Author(s):  
Nadhia Regitasari ◽  
M. Ridha Mak'ruf ◽  
Endang Dian Setioningsih

Fetal weight estimation during pregnancy is one of the beneficial ways to solve morbidity and death during labor problem. Manually, the fundal height is measured from the edge of the pubic symphysis to the top of the uterine fundus by following the arch of the uterus, using a measuring tape. The purpose of this study is to develop an easy way to count fetal weight estimation so midwives don’t have to count manually. The calculation of fetal weight estimation tool uses a variable resistor (potentiometer) as a sensor to measure the fundal height. Then it will be processed in microcontroller. The measurement results are fundal height and estimation fetal weight that will be displayed on the TFT LCD. Based on the results of measuring the fundus uterine height as much as 6 times against the measuring tool (ruler), there is no error in the device so it can be concluded that this tool can be used according to its function. This calculation of fetal weight estimation tool is portable and easy to use to help midwives count the fetal weight estimation quickly.


2008 ◽  
Vol 68 (S 01) ◽  
Author(s):  
NC Hart ◽  
J Siemer ◽  
B Meurer ◽  
TW Goecke ◽  
RL Schild

2011 ◽  
Vol 42 (S 01) ◽  
Author(s):  
D Tibussek ◽  
F Distelmaier ◽  
S Kummer ◽  
E Mayatepek

2017 ◽  
Author(s):  
D Balsyte ◽  
T Burkhardt ◽  
R Zimmermann ◽  
J Kurmanavicius

2020 ◽  
pp. 3-8
Author(s):  
L.F. Vitushkin ◽  
F.F. Karpeshin ◽  
E.P. Krivtsov ◽  
P.P. Krolitsky ◽  
V.V. Nalivaev ◽  
...  

The State special primary acceleration measurement standard for gravimetry (GET 190-2019), its composition, principle of operation and basic metrological characteristics are presented. This standard is on the upper level of reference for free-fall acceleration measurements. Its accuracy and reliability were improved as a result of optimisation of the adjustment procedures for measurement systems and its integration within the upgraded systems, units and modern hardware components. A special attention was given to adjusting the corrections applied to measurement results with respect to procedural, physical and technical limitations. The used investigation methods made it possibled to confirm the measurement range of GET 190-2019 and to determine the contributions of main sources of errors and the total value of these errors. The measurement characteristics and GET 90-2019 were confirmed by the results obtained from measurements of the absolute value of the free fall acceleration at the gravimetrical site “Lomonosov-1” and by their collation with the data of different dates obtained from measurements by high-precision foreign and domestic gravimeters. Topicality of such measurements ensues from the requirements to handle the applied problems that need data on parameters of the Earth gravitational field, to be adequately faced. Geophysics and navigation are the main fields of application for high-precision measurements in this field.


2020 ◽  
pp. 66-72
Author(s):  
Irina A. Piterskikh ◽  
Svetlana V. Vikhrova ◽  
Nina G. Kovaleva ◽  
Tatyana O. Barynskaya

Certified reference materials (CRM) composed of propyl (11383-2019) and isopropyl (11384-2019) alcohols solutions were created for validation of measurement procedures and control of measurement errors of measurement results of mass concentrations of toxic substances (alcohol) in biological objects (urine, blood) and water. Two ways of establishing the value of the certified characteristic – mass consentration of propanol-1 or propanol-2 have been studied. The results obtained by the preparation procedure and comparison with the standard are the same within the margin of error.


2020 ◽  
pp. 64-70
Author(s):  
Mariya Y. Medvedevskikh ◽  
Anna S. Sergeeva

The article raises the problem of ensuring metrological traceability of the measurement results of indicators of quality and nutritional value for food products and food raw materials: water (moisture), nitrogen (protein, crude protein), fat, ash and carbohydrates. The problem under consideration can be solved by applying reference materials of food composition, traceable to state primary measurement standards GET 173-2017 and GET 176-2019 and primary reference measurement procedures (PRMP), for attestation of measurement procedures and accuracy checking of measurement results. The article discusses the results of the PRMP development of mass fraction of fat, ash and carbohydrates in food products and food raw materials, as well as mass fraction of crude fat (oil content) in oil crops seeds and products based on them. The paper also presents metrological characteristics of reference materials of composition of dry dairy products, grain-milk dry porridges for nutrition of babies, grain dry porridges for nutrition of babies, egg powder, freeze-dried meat products, animal feed. The results of the work allow for building a chain of metrological traceability from GET 173-2017, GET 176-2019 and PRMP to routine measurement procedures, thereby ensuring the uniformity of measurements of nutritional value of food products.


2019 ◽  
Vol 11 (1) ◽  
pp. 32-38
Author(s):  
Naznin Rashid Shewly ◽  
Menoka Ferdous ◽  
Hasina Begum ◽  
Shahadat Hossain Khan ◽  
Sheema Rani Debee ◽  
...  

Background: In obstetric management fetal weight estimation is an important consideration when planning the mode of delivery in our day to day practice. In Bangladesh low birth weight is a major public health problem & incidence is 38% - 58%. Neonatal mortality and morbidity also yet high. So accurate antenatal estimation of fetal weight is a good way to detect macrosomia or small for date baby. Thus to improve the pregnancy outcome and neonatal outcome decreasing various chance of neonatal mortality and morbidity antenatal fetal weight prediction is an invaluable parameter in some situation where to identify the at risk pregnancy for low birth weight become necessary. Reliable method for prenatal estimation of fetal weight two modalities have got popularity - Clinical estimation and another one is ultrasonic estimation. This study was designed to determine the accuracy of clinical versus ultrasound estimated fetal weight detecting the discrepancy with actual birth weight at third trimester. So that we can verify more reliable and accurate method. Objectives: To find out more accurate and reliable modality of fetal weight estimation in antenatal period during obstetric management planning. To compare clinical versus ultrasound estimated fetal weight & to determine discrepancy of both variable with actual birth weight. Method: This prospective, cross sectional analytical study was carried out in Dhaka Medical College Hospital from January 2006 to December 2006. By purposive sampling 100 pregnant women fulfilling inclusion criteria were included in my study in third trimester (29wks-40wks). In clinical weight estimation procedure SFH (Symphysio Fundal Height) was measured in centimeter. On pervaginal finding whether vertex below or above the ischial spine was determined. By Johnson’s formula fetal weight in grams was estimated. Then by ultrasound scan different biometric measurements were taken and finally by Hadlock’s formula fetal weight was estimated. Eventually actual birth weight was taken after birth by Globe Brand weighing machine. Accuracy of both modalities were compared and which one was more reliable predictor was determined by statistical analysis. Results: After data collection were analyzed by computer based software (SPSS). There was gradual and positive relationship between symphysiofundal height and estimated birth weight. Discrepancy between clinical and actual birth weight at third trimester was statistically significant – Paired Student’s ‘t’ test was done where p value was <0.001. Whereas discrepancy between sonographically estimated fetal weight with actual birth weight was not statistically significant (by paired ‘t’ test where p value was >0.05). That implies discrepancy between ultrasound estimated fetal weight and actual birth weight was significantly less than that of clinically estimated fetal weight. 14% clinically and 46% sonographically estimated fetal weight were observed within £ 5% of actual birth weight. 31% clinical and 42% sonographically estimates observed within 6% to 10% of actual birth weight and 55% clinical and 12% sonographically estimate were >10% of actual birth weight. That is about 88% sonographical versus 45% clinical estimates were within 10% of actual birth weight. Conclusion: There is no doubt about importance of fetal weight in many obstetric situations. Clinical decisions at times depends on fetal weight. Whether to use oxytocin, to use forceps or vacuum for delivery or extend of trial or ended by Caesarian section immediately or no scope of trial to be largely depend on fetal size and weight. So more accurate modality for antenatal fetal weight estimation has paramount importance. In my study sonographically estimated weight have more accuracy than that of clinical estimate in predicting actual birth weight. Sonographically estimated fetal weight is more reliable, accurate and reproducible rather than other modality. J Shaheed Suhrawardy Med Coll, June 2019, Vol.11(1); 32-38


Reproduction ◽  
1972 ◽  
Vol 29 (1) ◽  
pp. 148-148
Author(s):  
C. Hetherington
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document